Cargando…

Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator

PURPOSE: The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycar...

Descripción completa

Detalles Bibliográficos
Autores principales: Alzand, B. S. N., Timmermans, C. C. M. M., Wellens, H. J. J., Dennert, R., Philippens, S. A. M., Portegijs, P. J. M., Rodriguez, LM.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3141830/
https://www.ncbi.nlm.nih.gov/pubmed/21340515
http://dx.doi.org/10.1007/s10840-011-9549-1
Descripción
Sumario:PURPOSE: The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. METHODS: The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial infarction and multiple and/or hemodynamically not tolerated ventricular tachycardia necessitating repeated device therapy. A total of 31 substrate modification procedures were performed using the three-dimensional electroanatomical mapping system. Patients were followed up for a median of 23.5 (interquartile range 6.5–53.2) months before and 37.8 (interquartile range 11.7–71.8) months after ablation. Antiarrhythmic drugs were not changed after the procedure, and were stopped 6 to 9 months after the procedure in patients who did not show ventricular tachycardia recurrence. RESULTS: Median ventricular tachycardias were 1.6 (interquartile range 0.7–6.7) per month before and 0.2 (interquartile range 0.00–1.3) per month after ablation (P = 0.006). Nine ventricular fibrillation episodes were registered in seven patients before and two after ablation (P = 0.025). Median antitachycardia pacing decreased from 1.6 (interquartile range 0.01–5.5) per month before to 0.18 (interquartile range 0.00–1.6) per month after ablation (P = 0.069). Median number of shocks decreased from 0.19 (interquartile range 0.04–0.81) per month before to 0.00 (interquartile range 0.00–0.09) per month after ablation (P = 0.001). One patient had a transient ischemic attack during the procedure, and another developed pericarditis. Nine patients died during follow-up, eight patients due to heart failure and one patient during valve surgery. CONCLUSION: Catheter-based substrate modification using voltage mapping results in a long-lasting reduction of cardioverter defibrillator therapy in patients with multiple and/or hemodynamically not tolerated infarct-related ventricular tachyarrhythmia.