Cargando…

An automated calibration method for non-see-through head mounted displays

Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical...

Descripción completa

Detalles Bibliográficos
Autores principales: Gilson, Stuart J., Fitzgibbon, Andrew W., Glennerster, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier/North-Holland Biomedical Press 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3142613/
https://www.ncbi.nlm.nih.gov/pubmed/21620891
http://dx.doi.org/10.1016/j.jneumeth.2011.05.011
_version_ 1782208845153566720
author Gilson, Stuart J.
Fitzgibbon, Andrew W.
Glennerster, Andrew
author_facet Gilson, Stuart J.
Fitzgibbon, Andrew W.
Glennerster, Andrew
author_sort Gilson, Stuart J.
collection PubMed
description Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical see-through HMDs. Building on our existing approach to HMD calibration Gilson et al. (2008), we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside a HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in multiple positions. The centroids of the markers on the calibration object are recovered and their locations re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the HMD display's intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors without the need for error-prone human judgements.
format Online
Article
Text
id pubmed-3142613
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Elsevier/North-Holland Biomedical Press
record_format MEDLINE/PubMed
spelling pubmed-31426132011-08-30 An automated calibration method for non-see-through head mounted displays Gilson, Stuart J. Fitzgibbon, Andrew W. Glennerster, Andrew J Neurosci Methods Article Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical see-through HMDs. Building on our existing approach to HMD calibration Gilson et al. (2008), we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside a HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in multiple positions. The centroids of the markers on the calibration object are recovered and their locations re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the HMD display's intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors without the need for error-prone human judgements. Elsevier/North-Holland Biomedical Press 2011-08-15 /pmc/articles/PMC3142613/ /pubmed/21620891 http://dx.doi.org/10.1016/j.jneumeth.2011.05.011 Text en © 2011 Elsevier B.V. https://creativecommons.org/licenses/by/3.0/ Open Access under CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) license
spellingShingle Article
Gilson, Stuart J.
Fitzgibbon, Andrew W.
Glennerster, Andrew
An automated calibration method for non-see-through head mounted displays
title An automated calibration method for non-see-through head mounted displays
title_full An automated calibration method for non-see-through head mounted displays
title_fullStr An automated calibration method for non-see-through head mounted displays
title_full_unstemmed An automated calibration method for non-see-through head mounted displays
title_short An automated calibration method for non-see-through head mounted displays
title_sort automated calibration method for non-see-through head mounted displays
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3142613/
https://www.ncbi.nlm.nih.gov/pubmed/21620891
http://dx.doi.org/10.1016/j.jneumeth.2011.05.011
work_keys_str_mv AT gilsonstuartj anautomatedcalibrationmethodfornonseethroughheadmounteddisplays
AT fitzgibbonandreww anautomatedcalibrationmethodfornonseethroughheadmounteddisplays
AT glennersterandrew anautomatedcalibrationmethodfornonseethroughheadmounteddisplays
AT gilsonstuartj automatedcalibrationmethodfornonseethroughheadmounteddisplays
AT fitzgibbonandreww automatedcalibrationmethodfornonseethroughheadmounteddisplays
AT glennersterandrew automatedcalibrationmethodfornonseethroughheadmounteddisplays