An automated calibration method for non-see-through head mounted displays
Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier/North-Holland Biomedical Press
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3142613/ https://www.ncbi.nlm.nih.gov/pubmed/21620891 http://dx.doi.org/10.1016/j.jneumeth.2011.05.011 |
_version_ | 1782208845153566720 |
---|---|
author | Gilson, Stuart J. Fitzgibbon, Andrew W. Glennerster, Andrew |
author_facet | Gilson, Stuart J. Fitzgibbon, Andrew W. Glennerster, Andrew |
author_sort | Gilson, Stuart J. |
collection | PubMed |
description | Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical see-through HMDs. Building on our existing approach to HMD calibration Gilson et al. (2008), we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside a HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in multiple positions. The centroids of the markers on the calibration object are recovered and their locations re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the HMD display's intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors without the need for error-prone human judgements. |
format | Online Article Text |
id | pubmed-3142613 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Elsevier/North-Holland Biomedical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-31426132011-08-30 An automated calibration method for non-see-through head mounted displays Gilson, Stuart J. Fitzgibbon, Andrew W. Glennerster, Andrew J Neurosci Methods Article Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical see-through HMDs. Building on our existing approach to HMD calibration Gilson et al. (2008), we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside a HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in multiple positions. The centroids of the markers on the calibration object are recovered and their locations re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the HMD display's intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors without the need for error-prone human judgements. Elsevier/North-Holland Biomedical Press 2011-08-15 /pmc/articles/PMC3142613/ /pubmed/21620891 http://dx.doi.org/10.1016/j.jneumeth.2011.05.011 Text en © 2011 Elsevier B.V. https://creativecommons.org/licenses/by/3.0/ Open Access under CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) license |
spellingShingle | Article Gilson, Stuart J. Fitzgibbon, Andrew W. Glennerster, Andrew An automated calibration method for non-see-through head mounted displays |
title | An automated calibration method for non-see-through head mounted displays |
title_full | An automated calibration method for non-see-through head mounted displays |
title_fullStr | An automated calibration method for non-see-through head mounted displays |
title_full_unstemmed | An automated calibration method for non-see-through head mounted displays |
title_short | An automated calibration method for non-see-through head mounted displays |
title_sort | automated calibration method for non-see-through head mounted displays |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3142613/ https://www.ncbi.nlm.nih.gov/pubmed/21620891 http://dx.doi.org/10.1016/j.jneumeth.2011.05.011 |
work_keys_str_mv | AT gilsonstuartj anautomatedcalibrationmethodfornonseethroughheadmounteddisplays AT fitzgibbonandreww anautomatedcalibrationmethodfornonseethroughheadmounteddisplays AT glennersterandrew anautomatedcalibrationmethodfornonseethroughheadmounteddisplays AT gilsonstuartj automatedcalibrationmethodfornonseethroughheadmounteddisplays AT fitzgibbonandreww automatedcalibrationmethodfornonseethroughheadmounteddisplays AT glennersterandrew automatedcalibrationmethodfornonseethroughheadmounteddisplays |