Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate os...

Descripción completa

Detalles Bibliográficos
Autores principales: Sonderegger, Juerg, Grob, Karl R., Kuster, Markus S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PAGEPress Publications 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3143947/
https://www.ncbi.nlm.nih.gov/pubmed/21808699
http://dx.doi.org/10.4081/or.2010.e4
_version_ 1782208952172281856
author Sonderegger, Juerg
Grob, Karl R.
Kuster, Markus S.
author_facet Sonderegger, Juerg
Grob, Karl R.
Kuster, Markus S.
author_sort Sonderegger, Juerg
collection PubMed
description Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent tibial and femoral fractures with not fully closed growth plates. Although many lower limb shaft fractures are managed successfully with intramedullary nails, there are some important advantages of open-reduction-and-plate fixation: the risk of malalignment, anterior knee pain, or nonunion seems to be lower. The surgeon performing a plate osteosynthesis has the possibility to influence fixation strength and micromotion at the fracture gap. Long plates and oblique screws at the plate ends increase fixation strength. However, the number of screws does influence stiffness and stability. Lag screws and screws close to the fracture site reduce micromotion dramatically. Dynamic plate osteosynthesis can be achieved by applying some simple rules: long plates with only a few screws should be used. Oblique screws at the plate ends increase the pullout strength. Two or three holes at the fracture site should be omitted. Lag screws, especially through the plate, must be avoided whenever possible. Compression is not required. Locking plates are recommended only in fractures close to the joint. When respecting these basic concepts, dynamic plate osteosynthesis is a safe procedure with a high healing and a low complication rate.
format Online
Article
Text
id pubmed-3143947
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher PAGEPress Publications
record_format MEDLINE/PubMed
spelling pubmed-31439472011-08-01 Dynamic plate osteosynthesis for fracture stabilization: how to do it Sonderegger, Juerg Grob, Karl R. Kuster, Markus S. Orthop Rev (Pavia) Review Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent tibial and femoral fractures with not fully closed growth plates. Although many lower limb shaft fractures are managed successfully with intramedullary nails, there are some important advantages of open-reduction-and-plate fixation: the risk of malalignment, anterior knee pain, or nonunion seems to be lower. The surgeon performing a plate osteosynthesis has the possibility to influence fixation strength and micromotion at the fracture gap. Long plates and oblique screws at the plate ends increase fixation strength. However, the number of screws does influence stiffness and stability. Lag screws and screws close to the fracture site reduce micromotion dramatically. Dynamic plate osteosynthesis can be achieved by applying some simple rules: long plates with only a few screws should be used. Oblique screws at the plate ends increase the pullout strength. Two or three holes at the fracture site should be omitted. Lag screws, especially through the plate, must be avoided whenever possible. Compression is not required. Locking plates are recommended only in fractures close to the joint. When respecting these basic concepts, dynamic plate osteosynthesis is a safe procedure with a high healing and a low complication rate. PAGEPress Publications 2010-03-20 /pmc/articles/PMC3143947/ /pubmed/21808699 http://dx.doi.org/10.4081/or.2010.e4 Text en ©Copyright J. Sonderegger et al., 2010 This work is licensed under a Creative Commons Attribution 3.0 License (by-nc 3.0). Licensee PAGEPress, Italy
spellingShingle Review
Sonderegger, Juerg
Grob, Karl R.
Kuster, Markus S.
Dynamic plate osteosynthesis for fracture stabilization: how to do it
title Dynamic plate osteosynthesis for fracture stabilization: how to do it
title_full Dynamic plate osteosynthesis for fracture stabilization: how to do it
title_fullStr Dynamic plate osteosynthesis for fracture stabilization: how to do it
title_full_unstemmed Dynamic plate osteosynthesis for fracture stabilization: how to do it
title_short Dynamic plate osteosynthesis for fracture stabilization: how to do it
title_sort dynamic plate osteosynthesis for fracture stabilization: how to do it
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3143947/
https://www.ncbi.nlm.nih.gov/pubmed/21808699
http://dx.doi.org/10.4081/or.2010.e4
work_keys_str_mv AT sondereggerjuerg dynamicplateosteosynthesisforfracturestabilizationhowtodoit
AT grobkarlr dynamicplateosteosynthesisforfracturestabilizationhowtodoit
AT kustermarkuss dynamicplateosteosynthesisforfracturestabilizationhowtodoit