Cargando…

Additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients

This is a retrospective analysis of the clinical and radiological outcome in 11 patients with complex acute posttraumatic elbow instability after dislocation. These patients had also been treated with a hinged external fixator after open reduction, capsular and ligamentous reconstruction and interna...

Descripción completa

Detalles Bibliográficos
Autores principales: Berendes, Sebastian, Zilkens, Christoph, Anastasiadis, Alexandros, Graf, Markus, Muhr, Gert, Kalicke, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PAGEPress Publications 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3143969/
https://www.ncbi.nlm.nih.gov/pubmed/21808711
http://dx.doi.org/10.4081/or.2010.e21
_version_ 1782208957833543680
author Berendes, Sebastian
Zilkens, Christoph
Anastasiadis, Alexandros
Graf, Markus
Muhr, Gert
Kalicke, Thomas
author_facet Berendes, Sebastian
Zilkens, Christoph
Anastasiadis, Alexandros
Graf, Markus
Muhr, Gert
Kalicke, Thomas
author_sort Berendes, Sebastian
collection PubMed
description This is a retrospective analysis of the clinical and radiological outcome in 11 patients with complex acute posttraumatic elbow instability after dislocation. These patients had also been treated with a hinged external fixator after open reduction, capsular and ligamentous reconstruction and internal fixation, because of an expected diminished compliance, to avoid a secondary dislocation of the internal fixation. Concentric stability and a sufficient range of motion of the elbow joint were achieved in all cases. Non-compliant patients were classified by the surgeon as not compliant or not able or not willing to cooperate post-operatively for various reasons, such as alcoholism, drug abuse, mental disability, cerebral trauma or senile dementia. Non-compliant patients had undergone open reduction and internal fixation of an acute posttraumatic unstable elbow. The addition of a hinged external fixator allows early intensive mobilization, and can protect and improve the clinical outcome after these complex elbow injuries. This evaluation remains, of course, largely subjective and decision making is not easy because in most cases, the patient was not known before surgery. Thus, the only patient exclusion criteria in this study was surgeon classification as “compliant”.
format Online
Article
Text
id pubmed-3143969
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher PAGEPress Publications
record_format MEDLINE/PubMed
spelling pubmed-31439692011-08-01 Additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients Berendes, Sebastian Zilkens, Christoph Anastasiadis, Alexandros Graf, Markus Muhr, Gert Kalicke, Thomas Orthop Rev (Pavia) Article This is a retrospective analysis of the clinical and radiological outcome in 11 patients with complex acute posttraumatic elbow instability after dislocation. These patients had also been treated with a hinged external fixator after open reduction, capsular and ligamentous reconstruction and internal fixation, because of an expected diminished compliance, to avoid a secondary dislocation of the internal fixation. Concentric stability and a sufficient range of motion of the elbow joint were achieved in all cases. Non-compliant patients were classified by the surgeon as not compliant or not able or not willing to cooperate post-operatively for various reasons, such as alcoholism, drug abuse, mental disability, cerebral trauma or senile dementia. Non-compliant patients had undergone open reduction and internal fixation of an acute posttraumatic unstable elbow. The addition of a hinged external fixator allows early intensive mobilization, and can protect and improve the clinical outcome after these complex elbow injuries. This evaluation remains, of course, largely subjective and decision making is not easy because in most cases, the patient was not known before surgery. Thus, the only patient exclusion criteria in this study was surgeon classification as “compliant”. PAGEPress Publications 2010-09-23 /pmc/articles/PMC3143969/ /pubmed/21808711 http://dx.doi.org/10.4081/or.2010.e21 Text en ©Copyright S. Berendes et al., 2010 This work is licensed under a Creative Commons Attribution 3.0 License (by-nc 3.0). Licensee PAGEPress, Italy
spellingShingle Article
Berendes, Sebastian
Zilkens, Christoph
Anastasiadis, Alexandros
Graf, Markus
Muhr, Gert
Kalicke, Thomas
Additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients
title Additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients
title_full Additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients
title_fullStr Additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients
title_full_unstemmed Additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients
title_short Additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients
title_sort additional external hinged fixator after open repositioning and internal fixation of acute elbow instability in non-compliant patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3143969/
https://www.ncbi.nlm.nih.gov/pubmed/21808711
http://dx.doi.org/10.4081/or.2010.e21
work_keys_str_mv AT berendessebastian additionalexternalhingedfixatorafteropenrepositioningandinternalfixationofacuteelbowinstabilityinnoncompliantpatients
AT zilkenschristoph additionalexternalhingedfixatorafteropenrepositioningandinternalfixationofacuteelbowinstabilityinnoncompliantpatients
AT anastasiadisalexandros additionalexternalhingedfixatorafteropenrepositioningandinternalfixationofacuteelbowinstabilityinnoncompliantpatients
AT grafmarkus additionalexternalhingedfixatorafteropenrepositioningandinternalfixationofacuteelbowinstabilityinnoncompliantpatients
AT muhrgert additionalexternalhingedfixatorafteropenrepositioningandinternalfixationofacuteelbowinstabilityinnoncompliantpatients
AT kalickethomas additionalexternalhingedfixatorafteropenrepositioningandinternalfixationofacuteelbowinstabilityinnoncompliantpatients