Cargando…

The Ringloc liner compared with the Hexloc liner in total hip arthroplasty

The aim of this study was to compare the 10-year survival rate, pelvic osteolysis frequency and linear head penetration rate of the Hexloc and Ringloc liners used together with a partially threaded porous and hydroxyapatite coated cup and the Bi-Metric uncemented femoral stem. The 15-year results fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Olof, Sköldenberg, Mats, Salemyr, Olle, Muren, Åke, Johansson, Torbjörn, Ahl, Henrik, Bodén
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PAGEPress Publications 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3143985/
https://www.ncbi.nlm.nih.gov/pubmed/21808678
http://dx.doi.org/10.4081/or.2009.e16
_version_ 1782208961221492736
author Olof, Sköldenberg
Mats, Salemyr
Olle, Muren
Åke, Johansson
Torbjörn, Ahl
Henrik, Bodén
author_facet Olof, Sköldenberg
Mats, Salemyr
Olle, Muren
Åke, Johansson
Torbjörn, Ahl
Henrik, Bodén
author_sort Olof, Sköldenberg
collection PubMed
description The aim of this study was to compare the 10-year survival rate, pelvic osteolysis frequency and linear head penetration rate of the Hexloc and Ringloc liners used together with a partially threaded porous and hydroxyapatite coated cup and the Bi-Metric uncemented femoral stem. The 15-year results for the cup with the Hexloc liner are also reported. We included 332 consecutive hips (166 Hexloc and 166 Ringloc) on 281 patients in the study. Revisions of prosthesis components were recorded and pelvic osteolytic lesions were assessed using radiographs and computed tomography. The linear head penetration rate was measured using the Martell method. The 10-year survival rate of the liner with revision due to liner wear and/or osteolysis as endpoint was 88% for the Hexloc liner and 98% for the Ringloc liner. The 15-year survival rate of the Hexloc liner was 67%. Pelvic osteolysis was found in 27% of the Hexloc and 19% of the Ringloc hips. After 15 years, 53% of the Hexloc hips had developed an osteolytic lesion. The linear head penetration rate was 0.16 mm/year for the Hexloc liner and 0.12 mm/year for the Ringloc liner. This paper is the first to describe the rapidly deteriorating survival up to 15 years with the old generation gamma-in-air sterilized polyethylene used in Hexloc liners. The newer Ringloc liner with the ArCom™ polyethylene has superior clinical results but a linear wear rate and frequency of osteolytic lesions that is higher than expected.
format Online
Article
Text
id pubmed-3143985
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher PAGEPress Publications
record_format MEDLINE/PubMed
spelling pubmed-31439852011-08-01 The Ringloc liner compared with the Hexloc liner in total hip arthroplasty Olof, Sköldenberg Mats, Salemyr Olle, Muren Åke, Johansson Torbjörn, Ahl Henrik, Bodén Orthop Rev (Pavia) Article The aim of this study was to compare the 10-year survival rate, pelvic osteolysis frequency and linear head penetration rate of the Hexloc and Ringloc liners used together with a partially threaded porous and hydroxyapatite coated cup and the Bi-Metric uncemented femoral stem. The 15-year results for the cup with the Hexloc liner are also reported. We included 332 consecutive hips (166 Hexloc and 166 Ringloc) on 281 patients in the study. Revisions of prosthesis components were recorded and pelvic osteolytic lesions were assessed using radiographs and computed tomography. The linear head penetration rate was measured using the Martell method. The 10-year survival rate of the liner with revision due to liner wear and/or osteolysis as endpoint was 88% for the Hexloc liner and 98% for the Ringloc liner. The 15-year survival rate of the Hexloc liner was 67%. Pelvic osteolysis was found in 27% of the Hexloc and 19% of the Ringloc hips. After 15 years, 53% of the Hexloc hips had developed an osteolytic lesion. The linear head penetration rate was 0.16 mm/year for the Hexloc liner and 0.12 mm/year for the Ringloc liner. This paper is the first to describe the rapidly deteriorating survival up to 15 years with the old generation gamma-in-air sterilized polyethylene used in Hexloc liners. The newer Ringloc liner with the ArCom™ polyethylene has superior clinical results but a linear wear rate and frequency of osteolytic lesions that is higher than expected. PAGEPress Publications 2009-10-10 /pmc/articles/PMC3143985/ /pubmed/21808678 http://dx.doi.org/10.4081/or.2009.e16 Text en ©Copyright O. Sköldenberg et al., 2009 This work is licensed under a Creative Commons Attribution 3.0 License (by-nc 3.0) Licensee PAGEPress, Italy
spellingShingle Article
Olof, Sköldenberg
Mats, Salemyr
Olle, Muren
Åke, Johansson
Torbjörn, Ahl
Henrik, Bodén
The Ringloc liner compared with the Hexloc liner in total hip arthroplasty
title The Ringloc liner compared with the Hexloc liner in total hip arthroplasty
title_full The Ringloc liner compared with the Hexloc liner in total hip arthroplasty
title_fullStr The Ringloc liner compared with the Hexloc liner in total hip arthroplasty
title_full_unstemmed The Ringloc liner compared with the Hexloc liner in total hip arthroplasty
title_short The Ringloc liner compared with the Hexloc liner in total hip arthroplasty
title_sort ringloc liner compared with the hexloc liner in total hip arthroplasty
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3143985/
https://www.ncbi.nlm.nih.gov/pubmed/21808678
http://dx.doi.org/10.4081/or.2009.e16
work_keys_str_mv AT olofskoldenberg theringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT matssalemyr theringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT ollemuren theringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT akejohansson theringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT torbjornahl theringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT henrikboden theringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT olofskoldenberg ringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT matssalemyr ringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT ollemuren ringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT akejohansson ringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT torbjornahl ringloclinercomparedwiththehexloclinerintotalhiparthroplasty
AT henrikboden ringloclinercomparedwiththehexloclinerintotalhiparthroplasty