Cargando…
Determination of Oxyclozanide in Beef and Milk using High-Performance Liquid Chromatography System with UV Detector
This study was developed and validated for the determination of oxyclozanide residue concentrations in beef and commercial milk, using high-performance liquid chromatography system. Oxyclozanide was successfully separated on a reverse phase column (Xbridge-C(18), 4.6×250 mm, 5 µm) with a mobile phas...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Association for Laboratory Animal Science
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3145990/ https://www.ncbi.nlm.nih.gov/pubmed/21826158 http://dx.doi.org/10.5625/lar.2011.27.1.37 |
_version_ | 1782209149028794368 |
---|---|
author | Jo, Kyul Cho, Hee-Jung Yi, Hee Cho, Soo-Min Park, Jin-A Kwon, Chan-Hyeok Park, Hee-Ra Kwon, Ki-Sung Shin, Ho-Chul |
author_facet | Jo, Kyul Cho, Hee-Jung Yi, Hee Cho, Soo-Min Park, Jin-A Kwon, Chan-Hyeok Park, Hee-Ra Kwon, Ki-Sung Shin, Ho-Chul |
author_sort | Jo, Kyul |
collection | PubMed |
description | This study was developed and validated for the determination of oxyclozanide residue concentrations in beef and commercial milk, using high-performance liquid chromatography system. Oxyclozanide was successfully separated on a reverse phase column (Xbridge-C(18), 4.6×250 mm, 5 µm) with a mobile phase composed of acetonitrile and 0.1% phosphoric acid (60:40, v/v%). This analytical procedure involved a deproteinization process using acetonitrile for beef and 2% formic acid in acetonitrile for commercial milk, dehydration by adding sodium sulfate to the liquid analytical sample, and a defatting process using n-hexane; after these steps, the extract was exposed to a stream of nitrogen dryness. The final extracted sample was dissolved in the mobile phase and filtered using a 0.45 µm syringe filter. This method had good selectivity and recovery (70.70±7.90-110.79±14.95%) from the matrices. The LOQs ranged from 9.7 to 9.8 µg/kg for beef and commercial milk. The recoveries met the standards set by the CODEX guideline. |
format | Online Article Text |
id | pubmed-3145990 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Korean Association for Laboratory Animal Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-31459902011-08-08 Determination of Oxyclozanide in Beef and Milk using High-Performance Liquid Chromatography System with UV Detector Jo, Kyul Cho, Hee-Jung Yi, Hee Cho, Soo-Min Park, Jin-A Kwon, Chan-Hyeok Park, Hee-Ra Kwon, Ki-Sung Shin, Ho-Chul Lab Anim Res Original Article This study was developed and validated for the determination of oxyclozanide residue concentrations in beef and commercial milk, using high-performance liquid chromatography system. Oxyclozanide was successfully separated on a reverse phase column (Xbridge-C(18), 4.6×250 mm, 5 µm) with a mobile phase composed of acetonitrile and 0.1% phosphoric acid (60:40, v/v%). This analytical procedure involved a deproteinization process using acetonitrile for beef and 2% formic acid in acetonitrile for commercial milk, dehydration by adding sodium sulfate to the liquid analytical sample, and a defatting process using n-hexane; after these steps, the extract was exposed to a stream of nitrogen dryness. The final extracted sample was dissolved in the mobile phase and filtered using a 0.45 µm syringe filter. This method had good selectivity and recovery (70.70±7.90-110.79±14.95%) from the matrices. The LOQs ranged from 9.7 to 9.8 µg/kg for beef and commercial milk. The recoveries met the standards set by the CODEX guideline. Korean Association for Laboratory Animal Science 2011-03 2011-03-25 /pmc/articles/PMC3145990/ /pubmed/21826158 http://dx.doi.org/10.5625/lar.2011.27.1.37 Text en Copyright © 2011 Korean Association for Laboratory Animal Science http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Jo, Kyul Cho, Hee-Jung Yi, Hee Cho, Soo-Min Park, Jin-A Kwon, Chan-Hyeok Park, Hee-Ra Kwon, Ki-Sung Shin, Ho-Chul Determination of Oxyclozanide in Beef and Milk using High-Performance Liquid Chromatography System with UV Detector |
title | Determination of Oxyclozanide in Beef and Milk using High-Performance Liquid Chromatography System with UV Detector |
title_full | Determination of Oxyclozanide in Beef and Milk using High-Performance Liquid Chromatography System with UV Detector |
title_fullStr | Determination of Oxyclozanide in Beef and Milk using High-Performance Liquid Chromatography System with UV Detector |
title_full_unstemmed | Determination of Oxyclozanide in Beef and Milk using High-Performance Liquid Chromatography System with UV Detector |
title_short | Determination of Oxyclozanide in Beef and Milk using High-Performance Liquid Chromatography System with UV Detector |
title_sort | determination of oxyclozanide in beef and milk using high-performance liquid chromatography system with uv detector |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3145990/ https://www.ncbi.nlm.nih.gov/pubmed/21826158 http://dx.doi.org/10.5625/lar.2011.27.1.37 |
work_keys_str_mv | AT jokyul determinationofoxyclozanideinbeefandmilkusinghighperformanceliquidchromatographysystemwithuvdetector AT choheejung determinationofoxyclozanideinbeefandmilkusinghighperformanceliquidchromatographysystemwithuvdetector AT yihee determinationofoxyclozanideinbeefandmilkusinghighperformanceliquidchromatographysystemwithuvdetector AT chosoomin determinationofoxyclozanideinbeefandmilkusinghighperformanceliquidchromatographysystemwithuvdetector AT parkjina determinationofoxyclozanideinbeefandmilkusinghighperformanceliquidchromatographysystemwithuvdetector AT kwonchanhyeok determinationofoxyclozanideinbeefandmilkusinghighperformanceliquidchromatographysystemwithuvdetector AT parkheera determinationofoxyclozanideinbeefandmilkusinghighperformanceliquidchromatographysystemwithuvdetector AT kwonkisung determinationofoxyclozanideinbeefandmilkusinghighperformanceliquidchromatographysystemwithuvdetector AT shinhochul determinationofoxyclozanideinbeefandmilkusinghighperformanceliquidchromatographysystemwithuvdetector |