Cargando…
Structural valve deterioration of a mitral Carpentier-Edwards pericardial bioprosthesis in an 87-year-old woman 16 years after its implantation
The second-generation pericardial valve, the Carpentier-Edwards perimount bioprosthetic (CEP) valve, shows dramatically improved durability as compared to the first-generation pericardial valve, and excellent performance has been obtained, in both the aortic and mitral positions. Especially in elder...
Autores principales: | Ito, Hiroshi, Sakata, Kensuke, Haruki, Takashi, Kobayashi, Yurio |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3149574/ https://www.ncbi.nlm.nih.gov/pubmed/21729285 http://dx.doi.org/10.1186/1749-8090-6-88 |
Ejemplares similares
-
The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability
por: Loor, Gabriel, et al.
Publicado: (2016) -
Structural valve deterioration of a pericardial bioprosthesis
por: Kattach, Hassan, et al.
Publicado: (2021) -
Natural History of a Carpentier-Edwards Pericardial Aortic Valve Replaced after 25 Years for Structural Valve Degeneration
por: Tchana-Sato, Vincent, et al.
Publicado: (2020) -
Eight‐year outcomes of aortic valve replacement with the Carpentier‐Edwards PERIMOUNT Magna Ease valve
por: Tsui, Steven, et al.
Publicado: (2022) -
Early Doppler-echocardiography evaluation of Carpentier-Edwards Standard and Carpentier-Edwards Magna aortic prosthetic valve: comparison of hemodynamic performance
por: Minardi, Giovanni, et al.
Publicado: (2011)