Fracture Toughness of Veneering Ceramics for Fused to Metal (PFM) and Zirconia Dental Restorative Materials

Veneering ceramics designed to be used with modern zirconia framework restorations have been reported to fracture occasionally in vivo. The fracture toughness of such veneering ceramics was measured and compared to that of conventional feldspathic porcelain veneering ceramics for metal framework res...

Descripción completa

Detalles Bibliográficos
Autores principales: Quinn, Janet B., Quinn, George D., Sundar, Veeraraghaven
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3152300/
https://www.ncbi.nlm.nih.gov/pubmed/21833158
http://dx.doi.org/10.6028/jres.115.024
_version_ 1782209752843943936
author Quinn, Janet B.
Quinn, George D.
Sundar, Veeraraghaven
author_facet Quinn, Janet B.
Quinn, George D.
Sundar, Veeraraghaven
author_sort Quinn, Janet B.
collection PubMed
description Veneering ceramics designed to be used with modern zirconia framework restorations have been reported to fracture occasionally in vivo. The fracture toughness of such veneering ceramics was measured and compared to that of conventional feldspathic porcelain veneering ceramics for metal framework restorations. The fracture toughness of the leucite free veneer was measured to be 0.73 MPa m ± 0.02 MPa m, which is less than that for the porcelain fused to metal (PFM) veneering ceramic: 1.10 MPa ± 0.2 MPa. (Uncertainties are one standard deviation unless otherwise noted.) The surface crack in flexure (SCF) method was suitable for both materials, but precrack identification was difficult for the leucite containing feldspathic porcelain PFM veneer.
format Online
Article
Text
id pubmed-3152300
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-31523002011-08-08 Fracture Toughness of Veneering Ceramics for Fused to Metal (PFM) and Zirconia Dental Restorative Materials Quinn, Janet B. Quinn, George D. Sundar, Veeraraghaven J Res Natl Inst Stand Technol Article Veneering ceramics designed to be used with modern zirconia framework restorations have been reported to fracture occasionally in vivo. The fracture toughness of such veneering ceramics was measured and compared to that of conventional feldspathic porcelain veneering ceramics for metal framework restorations. The fracture toughness of the leucite free veneer was measured to be 0.73 MPa m ± 0.02 MPa m, which is less than that for the porcelain fused to metal (PFM) veneering ceramic: 1.10 MPa ± 0.2 MPa. (Uncertainties are one standard deviation unless otherwise noted.) The surface crack in flexure (SCF) method was suitable for both materials, but precrack identification was difficult for the leucite containing feldspathic porcelain PFM veneer. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2010 2010-10-01 /pmc/articles/PMC3152300/ /pubmed/21833158 http://dx.doi.org/10.6028/jres.115.024 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Quinn, Janet B.
Quinn, George D.
Sundar, Veeraraghaven
Fracture Toughness of Veneering Ceramics for Fused to Metal (PFM) and Zirconia Dental Restorative Materials
title Fracture Toughness of Veneering Ceramics for Fused to Metal (PFM) and Zirconia Dental Restorative Materials
title_full Fracture Toughness of Veneering Ceramics for Fused to Metal (PFM) and Zirconia Dental Restorative Materials
title_fullStr Fracture Toughness of Veneering Ceramics for Fused to Metal (PFM) and Zirconia Dental Restorative Materials
title_full_unstemmed Fracture Toughness of Veneering Ceramics for Fused to Metal (PFM) and Zirconia Dental Restorative Materials
title_short Fracture Toughness of Veneering Ceramics for Fused to Metal (PFM) and Zirconia Dental Restorative Materials
title_sort fracture toughness of veneering ceramics for fused to metal (pfm) and zirconia dental restorative materials
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3152300/
https://www.ncbi.nlm.nih.gov/pubmed/21833158
http://dx.doi.org/10.6028/jres.115.024
work_keys_str_mv AT quinnjanetb fracturetoughnessofveneeringceramicsforfusedtometalpfmandzirconiadentalrestorativematerials
AT quinngeorged fracturetoughnessofveneeringceramicsforfusedtometalpfmandzirconiadentalrestorativematerials
AT sundarveeraraghaven fracturetoughnessofveneeringceramicsforfusedtometalpfmandzirconiadentalrestorativematerials