Cargando…
Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review
The present review is based on a survey of 21 studies on the cytocompatibility of medical biomaterials containing nickel, as assessed by cell culture of human and animal osteoblasts or osteoblast-like cells. Among the biomaterials evaluated were stainless steel, NiTi alloys, pure Ni, Ti, and other p...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Humana Press Inc
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3152710/ https://www.ncbi.nlm.nih.gov/pubmed/20703824 http://dx.doi.org/10.1007/s12011-010-8798-7 |
_version_ | 1782209790185832448 |
---|---|
author | Mikulewicz, Marcin Chojnacka, Katarzyna |
author_facet | Mikulewicz, Marcin Chojnacka, Katarzyna |
author_sort | Mikulewicz, Marcin |
collection | PubMed |
description | The present review is based on a survey of 21 studies on the cytocompatibility of medical biomaterials containing nickel, as assessed by cell culture of human and animal osteoblasts or osteoblast-like cells. Among the biomaterials evaluated were stainless steel, NiTi alloys, pure Ni, Ti, and other pure metals. The materials were either commercially available, prepared by the authors, or implanted by various techniques to generate a protective layer of oxides, nitrides, acetylides. The observation that the layers significantly reduced the initial release of metal ions and increased cytocompatibility was confirmed in cell culture experiments. Physical and chemical characterization of the materials was performed. This included, e.g., surface characterization (roughness, wettability, corrosion behavior, quantity of released ions, microhardness, and characterization of passivation layer). Cytocompatibility tests of the materials were conducted in the cultures of human or animal osteoblasts and osteoblast-like cells. The following assays were carried out: cell proliferation and viability test, adhesion test, morphology (by fluorescent microscopy or SEM). Also phenotypic and genotypic markers were investigated. In the majority of works, it was found that the most cytocompatible materials were stainless steel and NiTi alloy. Pure Ni was rendered and less cytocompatible. All the papers confirmed that the consequence of the formation of protective layers was in significant increase of cytocompatibility of the materials. This indicates the possible further modifications of the manufacturing process (formation of the passivation layer). |
format | Online Article Text |
id | pubmed-3152710 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Humana Press Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-31527102011-09-21 Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review Mikulewicz, Marcin Chojnacka, Katarzyna Biol Trace Elem Res Article The present review is based on a survey of 21 studies on the cytocompatibility of medical biomaterials containing nickel, as assessed by cell culture of human and animal osteoblasts or osteoblast-like cells. Among the biomaterials evaluated were stainless steel, NiTi alloys, pure Ni, Ti, and other pure metals. The materials were either commercially available, prepared by the authors, or implanted by various techniques to generate a protective layer of oxides, nitrides, acetylides. The observation that the layers significantly reduced the initial release of metal ions and increased cytocompatibility was confirmed in cell culture experiments. Physical and chemical characterization of the materials was performed. This included, e.g., surface characterization (roughness, wettability, corrosion behavior, quantity of released ions, microhardness, and characterization of passivation layer). Cytocompatibility tests of the materials were conducted in the cultures of human or animal osteoblasts and osteoblast-like cells. The following assays were carried out: cell proliferation and viability test, adhesion test, morphology (by fluorescent microscopy or SEM). Also phenotypic and genotypic markers were investigated. In the majority of works, it was found that the most cytocompatible materials were stainless steel and NiTi alloy. Pure Ni was rendered and less cytocompatible. All the papers confirmed that the consequence of the formation of protective layers was in significant increase of cytocompatibility of the materials. This indicates the possible further modifications of the manufacturing process (formation of the passivation layer). Humana Press Inc 2010-08-12 2011 /pmc/articles/PMC3152710/ /pubmed/20703824 http://dx.doi.org/10.1007/s12011-010-8798-7 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Article Mikulewicz, Marcin Chojnacka, Katarzyna Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review |
title | Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review |
title_full | Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review |
title_fullStr | Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review |
title_full_unstemmed | Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review |
title_short | Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review |
title_sort | cytocompatibility of medical biomaterials containing nickel by osteoblasts: a systematic literature review |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3152710/ https://www.ncbi.nlm.nih.gov/pubmed/20703824 http://dx.doi.org/10.1007/s12011-010-8798-7 |
work_keys_str_mv | AT mikulewiczmarcin cytocompatibilityofmedicalbiomaterialscontainingnickelbyosteoblastsasystematicliteraturereview AT chojnackakatarzyna cytocompatibilityofmedicalbiomaterialscontainingnickelbyosteoblastsasystematicliteraturereview |