Cargando…
Late Stent Thrombosis After Drug-Eluting Stent Implantation: A Rare Case of Accelerated Neo-Atherosclerosis and Early Manifestation of Neointimal Rupture
An 80-year old woman suffered from sudden onset of chest pain and dyspnea, and visited the emergency room. She received stent implantation with a biolimus A9-eluting stent (Nobori® 3.0×24 mm) at a the mid-portion of the left anterior descending artery 5 months prior to admission. The emergency 5-mon...
Autores principales: | Yang, Young-June, Kim, Mihyun, Kim, Choongki, Park, Junbeom, Oh, Jaewon, Won, Hoyoun, Kim, Byeong-Keuk, Hong, Myeong-Ki |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Cardiology
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3152738/ https://www.ncbi.nlm.nih.gov/pubmed/21860645 http://dx.doi.org/10.4070/kcj.2011.41.7.409 |
Ejemplares similares
-
Successful Management of a Rare Case of Stent Fracture and Subsequent Migration of the Fractured Stent Segment Into the Ascending Aorta in In-Stent Restenotic Lesions of a Saphenous Vein Graft
por: Won, Hoyoun, et al.
Publicado: (2012) -
Comparisons of the Effects of Stent Eccentricity on the Neointimal Hyperplasia between Sirolimus-Eluting Stent versus Paclitaxel-Eluting Stent
por: Kim, Byeong-Keuk, et al.
Publicado: (2010) -
Serial Changes of Neointimal Tissue after Everolimus-Eluting Stent Implantation in Porcine Coronary Artery: An Optical Coherence Tomography Analysis
por: Won, Hoyoun, et al.
Publicado: (2014) -
Very Late Stent Thrombosis due to Neointimal Rupture After Paclitaxel-Eluting Stent Implantation
por: Kee, Won Ju, et al.
Publicado: (2011) -
Corrigendum to “Serial Changes of Neointimal Tissue after Everolimus-Eluting Stent Implantation in Porcine Coronary Artery: An Optical Coherence Tomography Analysis”
por: Won, Hoyoun, et al.
Publicado: (2019)