Efficient Removal of Platelets from Peripheral Blood Progenitor Cell Products Using a Novel Micro-Chip Based Acoustophoretic Platform

BACKGROUND: Excessive collection of platelets is an unwanted side effect in current centrifugation-based peripheral blood progenitor cell (PBPC) apheresis. We investigated a novel microchip-based acoustophoresis technique, utilizing ultrasonic standing wave forces for the removal of platelets from P...

Descripción completa

Detalles Bibliográficos
Autores principales: Dykes, Josefina, Lenshof, Andreas, Åstrand-Grundström, Ing-Britt, Laurell, Thomas, Scheding, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3153458/
https://www.ncbi.nlm.nih.gov/pubmed/21857996
http://dx.doi.org/10.1371/journal.pone.0023074
_version_ 1782209901498466304
author Dykes, Josefina
Lenshof, Andreas
Åstrand-Grundström, Ing-Britt
Laurell, Thomas
Scheding, Stefan
author_facet Dykes, Josefina
Lenshof, Andreas
Åstrand-Grundström, Ing-Britt
Laurell, Thomas
Scheding, Stefan
author_sort Dykes, Josefina
collection PubMed
description BACKGROUND: Excessive collection of platelets is an unwanted side effect in current centrifugation-based peripheral blood progenitor cell (PBPC) apheresis. We investigated a novel microchip-based acoustophoresis technique, utilizing ultrasonic standing wave forces for the removal of platelets from PBPC products. By applying an acoustic standing wave field onto a continuously flowing cell suspension in a micro channel, cells can be separated from the surrounding media depending on their physical properties. STUDY DESIGN AND METHODS: PBPC samples were obtained from patients (n = 15) and healthy donors (n = 6) and sorted on an acoustophoresis-chip. The acoustic force was set to separate leukocytes from platelets into a target fraction and a waste fraction, respectively. The PBPC samples, the target and the waste fractions were analysed for cell recovery, purity and functionality. RESULTS: The median separation efficiency of leukocytes to the target fraction was 98% whereas platelets were effectively depleted by 89%. PBPC samples and corresponding target fractions were similar in the percentage of CD34+ hematopoetic progenitor/stem cells as well as leukocyte/lymphocyte subset distributions. Median viability was 98%, 98% and 97% in the PBPC samples, the target and the waste fractions, respectively. Results from hematopoietic progenitor cell assays indicated a preserved colony-forming ability post-sorting. Evaluation of platelet activation by P-selectin (CD62P) expression revealed a significant increase of CD62P+ platelets in the target (19%) and waste fractions (20%), respectively, compared to the PBPC input samples (9%). However, activation was lower when compared to stored blood bank platelet concentrates (48%). CONCLUSION: Acoustophoresis can be utilized to efficiently deplete PBPC samples of platelets, whilst preserving the target stem/progenitor cell and leukocyte cell populations, cell viability and progenitor cell colony-forming ability. Acoustophoresis is, thus, an interesting technology to improve current cell processing methods.
format Online
Article
Text
id pubmed-3153458
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-31534582011-08-19 Efficient Removal of Platelets from Peripheral Blood Progenitor Cell Products Using a Novel Micro-Chip Based Acoustophoretic Platform Dykes, Josefina Lenshof, Andreas Åstrand-Grundström, Ing-Britt Laurell, Thomas Scheding, Stefan PLoS One Research Article BACKGROUND: Excessive collection of platelets is an unwanted side effect in current centrifugation-based peripheral blood progenitor cell (PBPC) apheresis. We investigated a novel microchip-based acoustophoresis technique, utilizing ultrasonic standing wave forces for the removal of platelets from PBPC products. By applying an acoustic standing wave field onto a continuously flowing cell suspension in a micro channel, cells can be separated from the surrounding media depending on their physical properties. STUDY DESIGN AND METHODS: PBPC samples were obtained from patients (n = 15) and healthy donors (n = 6) and sorted on an acoustophoresis-chip. The acoustic force was set to separate leukocytes from platelets into a target fraction and a waste fraction, respectively. The PBPC samples, the target and the waste fractions were analysed for cell recovery, purity and functionality. RESULTS: The median separation efficiency of leukocytes to the target fraction was 98% whereas platelets were effectively depleted by 89%. PBPC samples and corresponding target fractions were similar in the percentage of CD34+ hematopoetic progenitor/stem cells as well as leukocyte/lymphocyte subset distributions. Median viability was 98%, 98% and 97% in the PBPC samples, the target and the waste fractions, respectively. Results from hematopoietic progenitor cell assays indicated a preserved colony-forming ability post-sorting. Evaluation of platelet activation by P-selectin (CD62P) expression revealed a significant increase of CD62P+ platelets in the target (19%) and waste fractions (20%), respectively, compared to the PBPC input samples (9%). However, activation was lower when compared to stored blood bank platelet concentrates (48%). CONCLUSION: Acoustophoresis can be utilized to efficiently deplete PBPC samples of platelets, whilst preserving the target stem/progenitor cell and leukocyte cell populations, cell viability and progenitor cell colony-forming ability. Acoustophoresis is, thus, an interesting technology to improve current cell processing methods. Public Library of Science 2011-08-09 /pmc/articles/PMC3153458/ /pubmed/21857996 http://dx.doi.org/10.1371/journal.pone.0023074 Text en Dykes et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Dykes, Josefina
Lenshof, Andreas
Åstrand-Grundström, Ing-Britt
Laurell, Thomas
Scheding, Stefan
Efficient Removal of Platelets from Peripheral Blood Progenitor Cell Products Using a Novel Micro-Chip Based Acoustophoretic Platform
title Efficient Removal of Platelets from Peripheral Blood Progenitor Cell Products Using a Novel Micro-Chip Based Acoustophoretic Platform
title_full Efficient Removal of Platelets from Peripheral Blood Progenitor Cell Products Using a Novel Micro-Chip Based Acoustophoretic Platform
title_fullStr Efficient Removal of Platelets from Peripheral Blood Progenitor Cell Products Using a Novel Micro-Chip Based Acoustophoretic Platform
title_full_unstemmed Efficient Removal of Platelets from Peripheral Blood Progenitor Cell Products Using a Novel Micro-Chip Based Acoustophoretic Platform
title_short Efficient Removal of Platelets from Peripheral Blood Progenitor Cell Products Using a Novel Micro-Chip Based Acoustophoretic Platform
title_sort efficient removal of platelets from peripheral blood progenitor cell products using a novel micro-chip based acoustophoretic platform
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3153458/
https://www.ncbi.nlm.nih.gov/pubmed/21857996
http://dx.doi.org/10.1371/journal.pone.0023074
work_keys_str_mv AT dykesjosefina efficientremovalofplateletsfromperipheralbloodprogenitorcellproductsusinganovelmicrochipbasedacoustophoreticplatform
AT lenshofandreas efficientremovalofplateletsfromperipheralbloodprogenitorcellproductsusinganovelmicrochipbasedacoustophoreticplatform
AT astrandgrundstromingbritt efficientremovalofplateletsfromperipheralbloodprogenitorcellproductsusinganovelmicrochipbasedacoustophoreticplatform
AT laurellthomas efficientremovalofplateletsfromperipheralbloodprogenitorcellproductsusinganovelmicrochipbasedacoustophoreticplatform
AT schedingstefan efficientremovalofplateletsfromperipheralbloodprogenitorcellproductsusinganovelmicrochipbasedacoustophoreticplatform