Cargando…
Assessment of intrahepatic blood flow by Doppler ultrasonography: Relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension
BACKGROUND: Abnormality of hepatic vein (HV) waveforms evaluated by Doppler ultrasonography has been widely studied in patients with chronic liver disease. We investigated the correlation between changes in HV waveforms and portal vein velocity (PVVel), the hepatic artery pulsatility index (HAPI), a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3156747/ https://www.ncbi.nlm.nih.gov/pubmed/21767412 http://dx.doi.org/10.1186/1471-230X-11-84 |
_version_ | 1782210230017327104 |
---|---|
author | Zhang, Li Yin, Jikai Duan, Yunyou Yang, Yilin Yuan, Lijun Cao, Tiesheng |
author_facet | Zhang, Li Yin, Jikai Duan, Yunyou Yang, Yilin Yuan, Lijun Cao, Tiesheng |
author_sort | Zhang, Li |
collection | PubMed |
description | BACKGROUND: Abnormality of hepatic vein (HV) waveforms evaluated by Doppler ultrasonography has been widely studied in patients with chronic liver disease. We investigated the correlation between changes in HV waveforms and portal vein velocity (PVVel), the hepatic artery pulsatility index (HAPI), and also the extent of abnormal Doppler HV waveforms expressed as damping index (DI), severity of portal hypertension expressed as Child-Pugh scores and portal pressure (PP) measured directly from patients with portal hypertension (PHT) to evaluate the indicative value of abnormal HV waveforms and discuss the cause of abnormal HV waveform. METHODS: Sixty patients who had been diagnosed with PHT and accepted surgical therapy of portosystemic shunts were investigated. PP was measured intraoperatively. Thirty healthy volunteers with no history of chronic liver disease were enrolled as the control group. HV waveforms were categorized as triphasic, biphasic or monophasic. DI was compared as the quantitative indicator of abnormal HV waveforms. Another two Doppler parameters, PVVel and HAPI were also measured. These Doppler features were compared with PP, Child-Pugh scores and histological changes assessed by liver biopsy. RESULTS: In the patient group, the Doppler flow waveforms in the middle HV were triphasic in 31.6%, biphasic in 46.7%, and monophasic in 21.6% of subjects. These figures were 86.7%, 10.0%, and 3.3%, respectively, in healthy subjects. With the flattening of HV waveforms, the HAPI increased significantly (r = 00.438, p < 0.0001), whereas PVVel decreased significantly (r = -0.44, p <0.0001). Blood flow parameters, HAPI, PVVel and HV-waveform changes showed no significant correlations with Child-Pugh scores. The latter showed a significant correlation with PP (r = 0.589, p = 0.044). Changes of HV waveform and DI significantly correlated with PP (r = 0.579, r = 0.473, p <0.0001), and significant correlation between DI and Child-Pugh scores was observed (r = 0.411, p = 0.001). PP was significantly different with respect to nodule size (p < 0.05), but HV-waveform changes were not significantly correlated with pathological changes. CONCLUSION: In patients with PHT, a monophasic HV waveform indicates higher portal pressure. Furthermore, quantitative indicator DI can reflect both higher portal pressure and more severe liver dysfunction. Flattening of HV waveforms accompanied by an increase in the HAPI and decrease in PVVel support the hypothesis that histological changes reducing HV compliance be the cause of abnormality of Doppler HV waveforms from the hemodynamic angle. |
format | Online Article Text |
id | pubmed-3156747 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-31567472011-08-17 Assessment of intrahepatic blood flow by Doppler ultrasonography: Relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension Zhang, Li Yin, Jikai Duan, Yunyou Yang, Yilin Yuan, Lijun Cao, Tiesheng BMC Gastroenterol Research Article BACKGROUND: Abnormality of hepatic vein (HV) waveforms evaluated by Doppler ultrasonography has been widely studied in patients with chronic liver disease. We investigated the correlation between changes in HV waveforms and portal vein velocity (PVVel), the hepatic artery pulsatility index (HAPI), and also the extent of abnormal Doppler HV waveforms expressed as damping index (DI), severity of portal hypertension expressed as Child-Pugh scores and portal pressure (PP) measured directly from patients with portal hypertension (PHT) to evaluate the indicative value of abnormal HV waveforms and discuss the cause of abnormal HV waveform. METHODS: Sixty patients who had been diagnosed with PHT and accepted surgical therapy of portosystemic shunts were investigated. PP was measured intraoperatively. Thirty healthy volunteers with no history of chronic liver disease were enrolled as the control group. HV waveforms were categorized as triphasic, biphasic or monophasic. DI was compared as the quantitative indicator of abnormal HV waveforms. Another two Doppler parameters, PVVel and HAPI were also measured. These Doppler features were compared with PP, Child-Pugh scores and histological changes assessed by liver biopsy. RESULTS: In the patient group, the Doppler flow waveforms in the middle HV were triphasic in 31.6%, biphasic in 46.7%, and monophasic in 21.6% of subjects. These figures were 86.7%, 10.0%, and 3.3%, respectively, in healthy subjects. With the flattening of HV waveforms, the HAPI increased significantly (r = 00.438, p < 0.0001), whereas PVVel decreased significantly (r = -0.44, p <0.0001). Blood flow parameters, HAPI, PVVel and HV-waveform changes showed no significant correlations with Child-Pugh scores. The latter showed a significant correlation with PP (r = 0.589, p = 0.044). Changes of HV waveform and DI significantly correlated with PP (r = 0.579, r = 0.473, p <0.0001), and significant correlation between DI and Child-Pugh scores was observed (r = 0.411, p = 0.001). PP was significantly different with respect to nodule size (p < 0.05), but HV-waveform changes were not significantly correlated with pathological changes. CONCLUSION: In patients with PHT, a monophasic HV waveform indicates higher portal pressure. Furthermore, quantitative indicator DI can reflect both higher portal pressure and more severe liver dysfunction. Flattening of HV waveforms accompanied by an increase in the HAPI and decrease in PVVel support the hypothesis that histological changes reducing HV compliance be the cause of abnormality of Doppler HV waveforms from the hemodynamic angle. BioMed Central 2011-07-19 /pmc/articles/PMC3156747/ /pubmed/21767412 http://dx.doi.org/10.1186/1471-230X-11-84 Text en Copyright ©2011 Zhang et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhang, Li Yin, Jikai Duan, Yunyou Yang, Yilin Yuan, Lijun Cao, Tiesheng Assessment of intrahepatic blood flow by Doppler ultrasonography: Relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension |
title | Assessment of intrahepatic blood flow by Doppler ultrasonography: Relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension |
title_full | Assessment of intrahepatic blood flow by Doppler ultrasonography: Relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension |
title_fullStr | Assessment of intrahepatic blood flow by Doppler ultrasonography: Relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension |
title_full_unstemmed | Assessment of intrahepatic blood flow by Doppler ultrasonography: Relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension |
title_short | Assessment of intrahepatic blood flow by Doppler ultrasonography: Relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension |
title_sort | assessment of intrahepatic blood flow by doppler ultrasonography: relationship between the hepatic vein, portal vein, hepatic artery and portal pressure measured intraoperatively in patients with portal hypertension |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3156747/ https://www.ncbi.nlm.nih.gov/pubmed/21767412 http://dx.doi.org/10.1186/1471-230X-11-84 |
work_keys_str_mv | AT zhangli assessmentofintrahepaticbloodflowbydopplerultrasonographyrelationshipbetweenthehepaticveinportalveinhepaticarteryandportalpressuremeasuredintraoperativelyinpatientswithportalhypertension AT yinjikai assessmentofintrahepaticbloodflowbydopplerultrasonographyrelationshipbetweenthehepaticveinportalveinhepaticarteryandportalpressuremeasuredintraoperativelyinpatientswithportalhypertension AT duanyunyou assessmentofintrahepaticbloodflowbydopplerultrasonographyrelationshipbetweenthehepaticveinportalveinhepaticarteryandportalpressuremeasuredintraoperativelyinpatientswithportalhypertension AT yangyilin assessmentofintrahepaticbloodflowbydopplerultrasonographyrelationshipbetweenthehepaticveinportalveinhepaticarteryandportalpressuremeasuredintraoperativelyinpatientswithportalhypertension AT yuanlijun assessmentofintrahepaticbloodflowbydopplerultrasonographyrelationshipbetweenthehepaticveinportalveinhepaticarteryandportalpressuremeasuredintraoperativelyinpatientswithportalhypertension AT caotiesheng assessmentofintrahepaticbloodflowbydopplerultrasonographyrelationshipbetweenthehepaticveinportalveinhepaticarteryandportalpressuremeasuredintraoperativelyinpatientswithportalhypertension |