Cargando…

The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage

Colorectal anastomotic leakage (AL) is a serious complication in colorectal surgery leading to high morbidity and mortality rates(1). The incidence of AL varies between 2.5 and 20% (2-5). Over the years, many strategies aimed at lowering the incidence of anastomotic leakage have been examined(6, 7)....

Descripción completa

Detalles Bibliográficos
Autores principales: Morks, Annelien N., Havenga, Klaas, ten Cate Hoedemaker, Henk O., Ploeg, Rutger J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MyJove Corporation 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3157857/
https://www.ncbi.nlm.nih.gov/pubmed/21085104
http://dx.doi.org/10.3791/2223
_version_ 1782210337565573120
author Morks, Annelien N.
Havenga, Klaas
ten Cate Hoedemaker, Henk O.
Ploeg, Rutger J.
author_facet Morks, Annelien N.
Havenga, Klaas
ten Cate Hoedemaker, Henk O.
Ploeg, Rutger J.
author_sort Morks, Annelien N.
collection PubMed
description Colorectal anastomotic leakage (AL) is a serious complication in colorectal surgery leading to high morbidity and mortality rates(1). The incidence of AL varies between 2.5 and 20% (2-5). Over the years, many strategies aimed at lowering the incidence of anastomotic leakage have been examined(6, 7). The cause of AL is probably multifactorial. Etiological factors include insufficient arterial blood supply, tension on the anastomosis, hematoma and/or infection at the anastomotic site, and co-morbid factors of the patient as diabetes and atherosclerosis(8). Furthermore, some anastomoses may be insufficient from the start due to technical failure. Currently a new device is developed in our institute aimed at protecting the colorectal anastomosis and lowering the incidence of AL. This so called C-seal is a biofragmentable drain, which is stapled to the anastomosis with the circular stapler. It covers the luminal side of the colorectal anastomosis thereby preventing leakage. The C-seal is a thin-walled tube-like drain, with an approximate diameter of 4 cm and an approximate length of 25 cm (figure 1). It is a tubular device composed of biodegradable polyurethane. Two flaps with adhesive tape are found at one end of the tube. These flaps are used to attach the C-seal to the anvil of the circular stapler, so that after the anastomosis is made the C-seal can be pulled through the anus. The C-seal remains in situ for at least 10 days. Thereafter it will lose strength and will degrade to be secreted from the body together with the gastrointestinal natural contents. The C-seal does not prevent the formation of dehiscences. However, it prevents extravasation of faeces into the peritoneal cavity. This means that a gap at the anastomotic site does not lead to leakage. Currently, a phase II study testing the C-seal in 35 patients undergoing (colo-)rectal resection with stapled anastomosis is recruiting. The C-seal can be used in both open procedures as well as laparoscopic procedures. The C-seal is only applied in stapled anastomoses within 15cm from the anal verge. In the video, application of the C-seal is shown in an open extended sigmoid resection in a patient suffering from diverticular disease with a stenotic colon.
format Online
Article
Text
id pubmed-3157857
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher MyJove Corporation
record_format MEDLINE/PubMed
spelling pubmed-31578572011-08-31 The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage Morks, Annelien N. Havenga, Klaas ten Cate Hoedemaker, Henk O. Ploeg, Rutger J. J Vis Exp Medicine Colorectal anastomotic leakage (AL) is a serious complication in colorectal surgery leading to high morbidity and mortality rates(1). The incidence of AL varies between 2.5 and 20% (2-5). Over the years, many strategies aimed at lowering the incidence of anastomotic leakage have been examined(6, 7). The cause of AL is probably multifactorial. Etiological factors include insufficient arterial blood supply, tension on the anastomosis, hematoma and/or infection at the anastomotic site, and co-morbid factors of the patient as diabetes and atherosclerosis(8). Furthermore, some anastomoses may be insufficient from the start due to technical failure. Currently a new device is developed in our institute aimed at protecting the colorectal anastomosis and lowering the incidence of AL. This so called C-seal is a biofragmentable drain, which is stapled to the anastomosis with the circular stapler. It covers the luminal side of the colorectal anastomosis thereby preventing leakage. The C-seal is a thin-walled tube-like drain, with an approximate diameter of 4 cm and an approximate length of 25 cm (figure 1). It is a tubular device composed of biodegradable polyurethane. Two flaps with adhesive tape are found at one end of the tube. These flaps are used to attach the C-seal to the anvil of the circular stapler, so that after the anastomosis is made the C-seal can be pulled through the anus. The C-seal remains in situ for at least 10 days. Thereafter it will lose strength and will degrade to be secreted from the body together with the gastrointestinal natural contents. The C-seal does not prevent the formation of dehiscences. However, it prevents extravasation of faeces into the peritoneal cavity. This means that a gap at the anastomotic site does not lead to leakage. Currently, a phase II study testing the C-seal in 35 patients undergoing (colo-)rectal resection with stapled anastomosis is recruiting. The C-seal can be used in both open procedures as well as laparoscopic procedures. The C-seal is only applied in stapled anastomoses within 15cm from the anal verge. In the video, application of the C-seal is shown in an open extended sigmoid resection in a patient suffering from diverticular disease with a stenotic colon. MyJove Corporation 2010-11-04 /pmc/articles/PMC3157857/ /pubmed/21085104 http://dx.doi.org/10.3791/2223 Text en Copyright © 2010, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Medicine
Morks, Annelien N.
Havenga, Klaas
ten Cate Hoedemaker, Henk O.
Ploeg, Rutger J.
The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage
title The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage
title_full The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage
title_fullStr The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage
title_full_unstemmed The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage
title_short The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage
title_sort c-seal: a biofragmentable drain protecting the stapled colorectal anastomosis from leakage
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3157857/
https://www.ncbi.nlm.nih.gov/pubmed/21085104
http://dx.doi.org/10.3791/2223
work_keys_str_mv AT morksannelienn thecsealabiofragmentabledrainprotectingthestapledcolorectalanastomosisfromleakage
AT havengaklaas thecsealabiofragmentabledrainprotectingthestapledcolorectalanastomosisfromleakage
AT tencatehoedemakerhenko thecsealabiofragmentabledrainprotectingthestapledcolorectalanastomosisfromleakage
AT ploegrutgerj thecsealabiofragmentabledrainprotectingthestapledcolorectalanastomosisfromleakage
AT morksannelienn csealabiofragmentabledrainprotectingthestapledcolorectalanastomosisfromleakage
AT havengaklaas csealabiofragmentabledrainprotectingthestapledcolorectalanastomosisfromleakage
AT tencatehoedemakerhenko csealabiofragmentabledrainprotectingthestapledcolorectalanastomosisfromleakage
AT ploegrutgerj csealabiofragmentabledrainprotectingthestapledcolorectalanastomosisfromleakage