Cargando…

Variation of beam characteristics between three different wedges from a dual-energy accelerator

The use of megavoltage X-ray sources of radiation, with their skin-sparing qualities in radiation therapy, has been proved useful in relieving patient discomfort and allowing higher tumor doses to be given with fewer restrictions due to radiation effects in the skin. The purpose of this study was to...

Descripción completa

Detalles Bibliográficos
Autores principales: Varatharaj, C., Ravikumar, M., Sathiyan, S., Supe, Sanjay S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3159219/
https://www.ncbi.nlm.nih.gov/pubmed/21897558
http://dx.doi.org/10.4103/0971-6203.83475
_version_ 1782210427172683776
author Varatharaj, C.
Ravikumar, M.
Sathiyan, S.
Supe, Sanjay S.
author_facet Varatharaj, C.
Ravikumar, M.
Sathiyan, S.
Supe, Sanjay S.
author_sort Varatharaj, C.
collection PubMed
description The use of megavoltage X-ray sources of radiation, with their skin-sparing qualities in radiation therapy, has been proved useful in relieving patient discomfort and allowing higher tumor doses to be given with fewer restrictions due to radiation effects in the skin. The purpose of this study was to compare the dosimetric characteristics of a physical and enhanced dynamic wedge from a dual-energy (6 and 18 MV) linear accelerator such as surfaces doses with different source to surface distances (SSD), half value layer (HVL) in water and peripheral doses for both available energies. At short SSD such as 85 cm, higher surface doses are produced by the lower wedges by the short wedge-to-skin distance. For physical wedged field, at heel edge side HVL value was high (17 cm) compared with the measured that of EDW (15.1 cm). It was noticed that, the HVL variation across the beam was significantly higher for 6 MV X-rays than for 18 MV X-rays. The lower wedge has the maximum variation of peripheral dose compared to other wedges. The three wedge systems discussed in this work possess vastly different dosimetric characteristics. These differences will have a direct impact on the choice of the wedge system to be used for a particular treatment. Complete knowledge of the dosimetric characterisitics, including the surface and peripheral doses, is crucial in proper choice of particular wedge systems in clinical use.
format Online
Article
Text
id pubmed-3159219
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-31592192011-09-06 Variation of beam characteristics between three different wedges from a dual-energy accelerator Varatharaj, C. Ravikumar, M. Sathiyan, S. Supe, Sanjay S. J Med Phys Original Article The use of megavoltage X-ray sources of radiation, with their skin-sparing qualities in radiation therapy, has been proved useful in relieving patient discomfort and allowing higher tumor doses to be given with fewer restrictions due to radiation effects in the skin. The purpose of this study was to compare the dosimetric characteristics of a physical and enhanced dynamic wedge from a dual-energy (6 and 18 MV) linear accelerator such as surfaces doses with different source to surface distances (SSD), half value layer (HVL) in water and peripheral doses for both available energies. At short SSD such as 85 cm, higher surface doses are produced by the lower wedges by the short wedge-to-skin distance. For physical wedged field, at heel edge side HVL value was high (17 cm) compared with the measured that of EDW (15.1 cm). It was noticed that, the HVL variation across the beam was significantly higher for 6 MV X-rays than for 18 MV X-rays. The lower wedge has the maximum variation of peripheral dose compared to other wedges. The three wedge systems discussed in this work possess vastly different dosimetric characteristics. These differences will have a direct impact on the choice of the wedge system to be used for a particular treatment. Complete knowledge of the dosimetric characterisitics, including the surface and peripheral doses, is crucial in proper choice of particular wedge systems in clinical use. Medknow Publications Pvt Ltd 2011 /pmc/articles/PMC3159219/ /pubmed/21897558 http://dx.doi.org/10.4103/0971-6203.83475 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Varatharaj, C.
Ravikumar, M.
Sathiyan, S.
Supe, Sanjay S.
Variation of beam characteristics between three different wedges from a dual-energy accelerator
title Variation of beam characteristics between three different wedges from a dual-energy accelerator
title_full Variation of beam characteristics between three different wedges from a dual-energy accelerator
title_fullStr Variation of beam characteristics between three different wedges from a dual-energy accelerator
title_full_unstemmed Variation of beam characteristics between three different wedges from a dual-energy accelerator
title_short Variation of beam characteristics between three different wedges from a dual-energy accelerator
title_sort variation of beam characteristics between three different wedges from a dual-energy accelerator
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3159219/
https://www.ncbi.nlm.nih.gov/pubmed/21897558
http://dx.doi.org/10.4103/0971-6203.83475
work_keys_str_mv AT varatharajc variationofbeamcharacteristicsbetweenthreedifferentwedgesfromadualenergyaccelerator
AT ravikumarm variationofbeamcharacteristicsbetweenthreedifferentwedgesfromadualenergyaccelerator
AT sathiyans variationofbeamcharacteristicsbetweenthreedifferentwedgesfromadualenergyaccelerator
AT supesanjays variationofbeamcharacteristicsbetweenthreedifferentwedgesfromadualenergyaccelerator