Cargando…

Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies Following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs

Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA) techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies...

Descripción completa

Detalles Bibliográficos
Autores principales: Patel, Jay, Layfield, Lester J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Libertas Academica 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3159997/
https://www.ncbi.nlm.nih.gov/pubmed/21876655
_version_ 1782210508083953664
author Patel, Jay
Layfield, Lester J.
author_facet Patel, Jay
Layfield, Lester J.
author_sort Patel, Jay
collection PubMed
description Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA) techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those of cytology specimens, including concerns regarding adequacy and the representative nature of the biopsy. Due to sample size, some neoplasms may not be diagnosed on initial biopsy, raising concerns regarding false negative results. Cytopathologists have instituted QA procedures including review of all previously negative slides received within five years prior to the new diagnosis of high grade squamous intraepithelial lesion or gynecologic malignancy. No such requirement exists in surgical pathology for review of core biopsies. The Department of Pathology at the University of Utah instituted a QA policy requiring review of prior negative prostatic needle biopsies following a new diagnosis of prostatic adenocarcinoma. We reviewed five years of QA records of prostate needle biopsy review. During this time, nine hundred and fifty-eight core biopsy sets were performed. Two hundred and ninety-five of these contained at least one biopsy with a diagnosis of adenocarcinoma. Two hundred and eight patients had a prior set of prostatic needle biopsies with a diagnosis of adenocarcinoma. The remaining 87 had prior biopsies with either a diagnosis of prostatic intraepithelial neoplasia (23), small atypical acinar proliferation (21) or no evidence of malignancy (43). QA review of these 87 cases revealed two biopsies which revealed foci of adenocarcinoma. Both had been initially diagnosed as no evidence of malignancy. The false negative rate for core biopsy was 0.68%. In an additional twenty-one cases, microscopic foci of atypical small acinar proliferations were found in core biopsies antedating the positive core biopsy (7.1%).
format Online
Article
Text
id pubmed-3159997
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Libertas Academica
record_format MEDLINE/PubMed
spelling pubmed-31599972011-08-29 Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies Following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs Patel, Jay Layfield, Lester J. Clin Med Pathol Original Research Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA) techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those of cytology specimens, including concerns regarding adequacy and the representative nature of the biopsy. Due to sample size, some neoplasms may not be diagnosed on initial biopsy, raising concerns regarding false negative results. Cytopathologists have instituted QA procedures including review of all previously negative slides received within five years prior to the new diagnosis of high grade squamous intraepithelial lesion or gynecologic malignancy. No such requirement exists in surgical pathology for review of core biopsies. The Department of Pathology at the University of Utah instituted a QA policy requiring review of prior negative prostatic needle biopsies following a new diagnosis of prostatic adenocarcinoma. We reviewed five years of QA records of prostate needle biopsy review. During this time, nine hundred and fifty-eight core biopsy sets were performed. Two hundred and ninety-five of these contained at least one biopsy with a diagnosis of adenocarcinoma. Two hundred and eight patients had a prior set of prostatic needle biopsies with a diagnosis of adenocarcinoma. The remaining 87 had prior biopsies with either a diagnosis of prostatic intraepithelial neoplasia (23), small atypical acinar proliferation (21) or no evidence of malignancy (43). QA review of these 87 cases revealed two biopsies which revealed foci of adenocarcinoma. Both had been initially diagnosed as no evidence of malignancy. The false negative rate for core biopsy was 0.68%. In an additional twenty-one cases, microscopic foci of atypical small acinar proliferations were found in core biopsies antedating the positive core biopsy (7.1%). Libertas Academica 2008-09-16 /pmc/articles/PMC3159997/ /pubmed/21876655 Text en © the author(s), publisher and licensee Libertas Academica Ltd. http://creativecommons.org/licenses/by/3.0 This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license http://creativecommons.org/licenses/by/3.0/).
spellingShingle Original Research
Patel, Jay
Layfield, Lester J.
Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies Following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs
title Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies Following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs
title_full Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies Following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs
title_fullStr Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies Following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs
title_full_unstemmed Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies Following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs
title_short Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies Following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs
title_sort histopathologic review of previously negative prostatic core needle biopsies following a new diagnosis of adenocarcinoma of the prostate by core needle biopsies: implications for quality assurance programs
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3159997/
https://www.ncbi.nlm.nih.gov/pubmed/21876655
work_keys_str_mv AT pateljay histopathologicreviewofpreviouslynegativeprostaticcoreneedlebiopsiesfollowinganewdiagnosisofadenocarcinomaoftheprostatebycoreneedlebiopsiesimplicationsforqualityassuranceprograms
AT layfieldlesterj histopathologicreviewofpreviouslynegativeprostaticcoreneedlebiopsiesfollowinganewdiagnosisofadenocarcinomaoftheprostatebycoreneedlebiopsiesimplicationsforqualityassuranceprograms