Cargando…
The prone 12 o'clock position reduces ileal intubation time during colonoscopy compared to the left lateral 6 o'clock (standard) position
BACKGROUND: Ileal intubation is the gold standard for a complete colonoscopy. However, despite evidence of clinical benefit ileoscopy is not always attempted due to perceived technical difficulty. Our aim was to compare time taken for ileal intubation using a new position-the prone 12 o'clock p...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3160404/ https://www.ncbi.nlm.nih.gov/pubmed/21816067 http://dx.doi.org/10.1186/1471-230X-11-89 |
_version_ | 1782210554160480256 |
---|---|
author | De Silva, Arjuna P Kumarasena, Ravindu S Perera Keragala, Suramya D Kalubowila, Udaya Niriella, Madunil Dassanayake, Anuradha S Pathmeswaran, Arunasalam de Silva, H Janaka |
author_facet | De Silva, Arjuna P Kumarasena, Ravindu S Perera Keragala, Suramya D Kalubowila, Udaya Niriella, Madunil Dassanayake, Anuradha S Pathmeswaran, Arunasalam de Silva, H Janaka |
author_sort | De Silva, Arjuna P |
collection | PubMed |
description | BACKGROUND: Ileal intubation is the gold standard for a complete colonoscopy. However, despite evidence of clinical benefit ileoscopy is not always attempted due to perceived technical difficulty. Our aim was to compare time taken for ileal intubation using a new position-the prone 12 o'clock position (PP) with the standard method (left lateral 6 o'clock position-LLP). METHODS: We performed a pilot study using fluoroscopy to determine the best patient position for ileal intubation. This was the prone 12 o'clock position. Patients were colonoscoped in the left lateral position and then randomized to ileal intubation in the 6 o'clock position(LL) or the 12 o'clock (PP) position. RESULTS: 202 consecutive patients were referred for colonoscopy. Colonoscopy was performed on 150 patients [82 females, mean (SD) age 53 (16) years]. 75 patients were randomized for ileal intubation in the PP and 75 patients in the LLP. Overall, the ileum was successfully intubated in 145 (96%) patients [74 (98.7%) in the PP and71 (94.7%) in the LLP]. The median (Interquartile Range) ileal intubation time was 12 (10) seconds in the PP and 87 (82) seconds in the LLP (p < 0.0001; Mann-Whitney U test). The ileum was abnormal in 11 (7.5%) patients. CONCLUSIONS: During colonoscopy, the prone 12 o'clock position gives a more direct approach to the ileo-caecal valve and significantly reduces ileal intubation time. TRIAL REGISTRATION: Trial registry: Sri Lanka Clinical Trial Registry Clinical trial registry number: SLCTR/2009/002 |
format | Online Article Text |
id | pubmed-3160404 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-31604042011-08-24 The prone 12 o'clock position reduces ileal intubation time during colonoscopy compared to the left lateral 6 o'clock (standard) position De Silva, Arjuna P Kumarasena, Ravindu S Perera Keragala, Suramya D Kalubowila, Udaya Niriella, Madunil Dassanayake, Anuradha S Pathmeswaran, Arunasalam de Silva, H Janaka BMC Gastroenterol Research Article BACKGROUND: Ileal intubation is the gold standard for a complete colonoscopy. However, despite evidence of clinical benefit ileoscopy is not always attempted due to perceived technical difficulty. Our aim was to compare time taken for ileal intubation using a new position-the prone 12 o'clock position (PP) with the standard method (left lateral 6 o'clock position-LLP). METHODS: We performed a pilot study using fluoroscopy to determine the best patient position for ileal intubation. This was the prone 12 o'clock position. Patients were colonoscoped in the left lateral position and then randomized to ileal intubation in the 6 o'clock position(LL) or the 12 o'clock (PP) position. RESULTS: 202 consecutive patients were referred for colonoscopy. Colonoscopy was performed on 150 patients [82 females, mean (SD) age 53 (16) years]. 75 patients were randomized for ileal intubation in the PP and 75 patients in the LLP. Overall, the ileum was successfully intubated in 145 (96%) patients [74 (98.7%) in the PP and71 (94.7%) in the LLP]. The median (Interquartile Range) ileal intubation time was 12 (10) seconds in the PP and 87 (82) seconds in the LLP (p < 0.0001; Mann-Whitney U test). The ileum was abnormal in 11 (7.5%) patients. CONCLUSIONS: During colonoscopy, the prone 12 o'clock position gives a more direct approach to the ileo-caecal valve and significantly reduces ileal intubation time. TRIAL REGISTRATION: Trial registry: Sri Lanka Clinical Trial Registry Clinical trial registry number: SLCTR/2009/002 BioMed Central 2011-08-04 /pmc/articles/PMC3160404/ /pubmed/21816067 http://dx.doi.org/10.1186/1471-230X-11-89 Text en Copyright ©2011 De Silva et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article De Silva, Arjuna P Kumarasena, Ravindu S Perera Keragala, Suramya D Kalubowila, Udaya Niriella, Madunil Dassanayake, Anuradha S Pathmeswaran, Arunasalam de Silva, H Janaka The prone 12 o'clock position reduces ileal intubation time during colonoscopy compared to the left lateral 6 o'clock (standard) position |
title | The prone 12 o'clock position reduces ileal intubation time during colonoscopy compared to the left lateral 6 o'clock (standard) position |
title_full | The prone 12 o'clock position reduces ileal intubation time during colonoscopy compared to the left lateral 6 o'clock (standard) position |
title_fullStr | The prone 12 o'clock position reduces ileal intubation time during colonoscopy compared to the left lateral 6 o'clock (standard) position |
title_full_unstemmed | The prone 12 o'clock position reduces ileal intubation time during colonoscopy compared to the left lateral 6 o'clock (standard) position |
title_short | The prone 12 o'clock position reduces ileal intubation time during colonoscopy compared to the left lateral 6 o'clock (standard) position |
title_sort | prone 12 o'clock position reduces ileal intubation time during colonoscopy compared to the left lateral 6 o'clock (standard) position |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3160404/ https://www.ncbi.nlm.nih.gov/pubmed/21816067 http://dx.doi.org/10.1186/1471-230X-11-89 |
work_keys_str_mv | AT desilvaarjunap theprone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT kumarasenaravindus theprone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT pererakeragalasuramyad theprone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT kalubowilaudaya theprone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT niriellamadunil theprone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT dassanayakeanuradhas theprone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT pathmeswaranarunasalam theprone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT desilvahjanaka theprone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT desilvaarjunap prone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT kumarasenaravindus prone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT pererakeragalasuramyad prone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT kalubowilaudaya prone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT niriellamadunil prone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT dassanayakeanuradhas prone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT pathmeswaranarunasalam prone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition AT desilvahjanaka prone12oclockpositionreducesilealintubationtimeduringcolonoscopycomparedtotheleftlateral6oclockstandardposition |