Cargando…
Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
BACKGROUND: The forced oscillation technique (FOT) is a simple method for assessing the oscillatory mechanics of the respiratory system. The oscillatory properties, respiratory system resistance (Rrs) and reactance (Xrs), are calculated from the oscillatory pressure/flow relationship. Although the F...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3166920/ https://www.ncbi.nlm.nih.gov/pubmed/21798069 http://dx.doi.org/10.1186/1475-925X-10-65 |
_version_ | 1782211205998313472 |
---|---|
author | Ohishi, Junichi Kurosawa, Hajime |
author_facet | Ohishi, Junichi Kurosawa, Hajime |
author_sort | Ohishi, Junichi |
collection | PubMed |
description | BACKGROUND: The forced oscillation technique (FOT) is a simple method for assessing the oscillatory mechanics of the respiratory system. The oscillatory properties, respiratory system resistance (Rrs) and reactance (Xrs), are calculated from the oscillatory pressure/flow relationship. Although the FOT has been a well-established technique, some detailed experimental conditions would be different among institutions. METHODS: We evaluated whether time lags produced by the experimental conditions such as different positions of the sensors can affect the accuracy of the FOT. If the position of the pressure sensor is different from the flow sensor, a time lag may occur in the measurements. The effect of the time lag was studied by numerical analysis. RESULTS: Rrs was estimated to be increased and Xrs decreased with an increase in the time lag, especially at a high oscillatory frequency of the medium-frequency range (5-35 Hz). At the high-frequency range (10-500 Hz), Rrs and Xrs were strikingly different in the values of the time lag. CONCLUSION: A time lag between the oscillatory pressure and flow may be involved in the accuracy of the FOT, suggesting that it needs to be minimized or compensated for with signal processing. Researchers should pay attention to such detailed experimental conditions of the FOT apparatus. |
format | Online Article Text |
id | pubmed-3166920 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-31669202011-09-06 Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique Ohishi, Junichi Kurosawa, Hajime Biomed Eng Online Letter to the Editor BACKGROUND: The forced oscillation technique (FOT) is a simple method for assessing the oscillatory mechanics of the respiratory system. The oscillatory properties, respiratory system resistance (Rrs) and reactance (Xrs), are calculated from the oscillatory pressure/flow relationship. Although the FOT has been a well-established technique, some detailed experimental conditions would be different among institutions. METHODS: We evaluated whether time lags produced by the experimental conditions such as different positions of the sensors can affect the accuracy of the FOT. If the position of the pressure sensor is different from the flow sensor, a time lag may occur in the measurements. The effect of the time lag was studied by numerical analysis. RESULTS: Rrs was estimated to be increased and Xrs decreased with an increase in the time lag, especially at a high oscillatory frequency of the medium-frequency range (5-35 Hz). At the high-frequency range (10-500 Hz), Rrs and Xrs were strikingly different in the values of the time lag. CONCLUSION: A time lag between the oscillatory pressure and flow may be involved in the accuracy of the FOT, suggesting that it needs to be minimized or compensated for with signal processing. Researchers should pay attention to such detailed experimental conditions of the FOT apparatus. BioMed Central 2011-07-29 /pmc/articles/PMC3166920/ /pubmed/21798069 http://dx.doi.org/10.1186/1475-925X-10-65 Text en Copyright ©2011 Ohishi and Kurosawa; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Letter to the Editor Ohishi, Junichi Kurosawa, Hajime Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique |
title | Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique |
title_full | Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique |
title_fullStr | Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique |
title_full_unstemmed | Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique |
title_short | Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique |
title_sort | time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique |
topic | Letter to the Editor |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3166920/ https://www.ncbi.nlm.nih.gov/pubmed/21798069 http://dx.doi.org/10.1186/1475-925X-10-65 |
work_keys_str_mv | AT ohishijunichi timelagbetweenoscillatorypressureandflowaffectingaccuracyofforcedoscillationtechnique AT kurosawahajime timelagbetweenoscillatorypressureandflowaffectingaccuracyofforcedoscillationtechnique |