Cargando…

Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique

BACKGROUND: The forced oscillation technique (FOT) is a simple method for assessing the oscillatory mechanics of the respiratory system. The oscillatory properties, respiratory system resistance (Rrs) and reactance (Xrs), are calculated from the oscillatory pressure/flow relationship. Although the F...

Descripción completa

Detalles Bibliográficos
Autores principales: Ohishi, Junichi, Kurosawa, Hajime
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3166920/
https://www.ncbi.nlm.nih.gov/pubmed/21798069
http://dx.doi.org/10.1186/1475-925X-10-65
_version_ 1782211205998313472
author Ohishi, Junichi
Kurosawa, Hajime
author_facet Ohishi, Junichi
Kurosawa, Hajime
author_sort Ohishi, Junichi
collection PubMed
description BACKGROUND: The forced oscillation technique (FOT) is a simple method for assessing the oscillatory mechanics of the respiratory system. The oscillatory properties, respiratory system resistance (Rrs) and reactance (Xrs), are calculated from the oscillatory pressure/flow relationship. Although the FOT has been a well-established technique, some detailed experimental conditions would be different among institutions. METHODS: We evaluated whether time lags produced by the experimental conditions such as different positions of the sensors can affect the accuracy of the FOT. If the position of the pressure sensor is different from the flow sensor, a time lag may occur in the measurements. The effect of the time lag was studied by numerical analysis. RESULTS: Rrs was estimated to be increased and Xrs decreased with an increase in the time lag, especially at a high oscillatory frequency of the medium-frequency range (5-35 Hz). At the high-frequency range (10-500 Hz), Rrs and Xrs were strikingly different in the values of the time lag. CONCLUSION: A time lag between the oscillatory pressure and flow may be involved in the accuracy of the FOT, suggesting that it needs to be minimized or compensated for with signal processing. Researchers should pay attention to such detailed experimental conditions of the FOT apparatus.
format Online
Article
Text
id pubmed-3166920
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31669202011-09-06 Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique Ohishi, Junichi Kurosawa, Hajime Biomed Eng Online Letter to the Editor BACKGROUND: The forced oscillation technique (FOT) is a simple method for assessing the oscillatory mechanics of the respiratory system. The oscillatory properties, respiratory system resistance (Rrs) and reactance (Xrs), are calculated from the oscillatory pressure/flow relationship. Although the FOT has been a well-established technique, some detailed experimental conditions would be different among institutions. METHODS: We evaluated whether time lags produced by the experimental conditions such as different positions of the sensors can affect the accuracy of the FOT. If the position of the pressure sensor is different from the flow sensor, a time lag may occur in the measurements. The effect of the time lag was studied by numerical analysis. RESULTS: Rrs was estimated to be increased and Xrs decreased with an increase in the time lag, especially at a high oscillatory frequency of the medium-frequency range (5-35 Hz). At the high-frequency range (10-500 Hz), Rrs and Xrs were strikingly different in the values of the time lag. CONCLUSION: A time lag between the oscillatory pressure and flow may be involved in the accuracy of the FOT, suggesting that it needs to be minimized or compensated for with signal processing. Researchers should pay attention to such detailed experimental conditions of the FOT apparatus. BioMed Central 2011-07-29 /pmc/articles/PMC3166920/ /pubmed/21798069 http://dx.doi.org/10.1186/1475-925X-10-65 Text en Copyright ©2011 Ohishi and Kurosawa; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Letter to the Editor
Ohishi, Junichi
Kurosawa, Hajime
Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
title Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
title_full Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
title_fullStr Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
title_full_unstemmed Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
title_short Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
title_sort time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
topic Letter to the Editor
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3166920/
https://www.ncbi.nlm.nih.gov/pubmed/21798069
http://dx.doi.org/10.1186/1475-925X-10-65
work_keys_str_mv AT ohishijunichi timelagbetweenoscillatorypressureandflowaffectingaccuracyofforcedoscillationtechnique
AT kurosawahajime timelagbetweenoscillatorypressureandflowaffectingaccuracyofforcedoscillationtechnique