Cargando…

Novel Diagnostic Model for the Deficient and Excess Pulse Qualities

The deficient and excess pulse qualities (DEPs) are the two representatives of the deficiency and excess syndromes, respectively. Despite its importance in the objectification of pulse diagnosis, a reliable classification model for the DEPs has not been reported to date. In this work, we propose a c...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jaeuk U., Jeon, Young Ju, Kim, Young-Min, Lee, Hae Jung, Kim, Jong Yeol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3167191/
https://www.ncbi.nlm.nih.gov/pubmed/21941587
http://dx.doi.org/10.1155/2012/563958
_version_ 1782211228821618688
author Kim, Jaeuk U.
Jeon, Young Ju
Kim, Young-Min
Lee, Hae Jung
Kim, Jong Yeol
author_facet Kim, Jaeuk U.
Jeon, Young Ju
Kim, Young-Min
Lee, Hae Jung
Kim, Jong Yeol
author_sort Kim, Jaeuk U.
collection PubMed
description The deficient and excess pulse qualities (DEPs) are the two representatives of the deficiency and excess syndromes, respectively. Despite its importance in the objectification of pulse diagnosis, a reliable classification model for the DEPs has not been reported to date. In this work, we propose a classification method for the DEPs based on a clinical study. First, through factor analysis and Fisher's discriminant analysis, we show that all the pulse amplitudes obtained at various applied pressures at Chon, Gwan, and Cheok contribute on equal orders of magnitude in the determination of the DEPs. Then, we discuss that the pulse pressure or the average pulse amplitude is appropriate for describing the collective behaviors of the pulse amplitudes and a simple and reliable classification can be constructed from either quantity. Finally, we propose an enhanced classification model that combines the two complementary variables sequentially.
format Online
Article
Text
id pubmed-3167191
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-31671912011-09-22 Novel Diagnostic Model for the Deficient and Excess Pulse Qualities Kim, Jaeuk U. Jeon, Young Ju Kim, Young-Min Lee, Hae Jung Kim, Jong Yeol Evid Based Complement Alternat Med Research Article The deficient and excess pulse qualities (DEPs) are the two representatives of the deficiency and excess syndromes, respectively. Despite its importance in the objectification of pulse diagnosis, a reliable classification model for the DEPs has not been reported to date. In this work, we propose a classification method for the DEPs based on a clinical study. First, through factor analysis and Fisher's discriminant analysis, we show that all the pulse amplitudes obtained at various applied pressures at Chon, Gwan, and Cheok contribute on equal orders of magnitude in the determination of the DEPs. Then, we discuss that the pulse pressure or the average pulse amplitude is appropriate for describing the collective behaviors of the pulse amplitudes and a simple and reliable classification can be constructed from either quantity. Finally, we propose an enhanced classification model that combines the two complementary variables sequentially. Hindawi Publishing Corporation 2012 2011-09-05 /pmc/articles/PMC3167191/ /pubmed/21941587 http://dx.doi.org/10.1155/2012/563958 Text en Copyright © 2012 Jaeuk U. Kim et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kim, Jaeuk U.
Jeon, Young Ju
Kim, Young-Min
Lee, Hae Jung
Kim, Jong Yeol
Novel Diagnostic Model for the Deficient and Excess Pulse Qualities
title Novel Diagnostic Model for the Deficient and Excess Pulse Qualities
title_full Novel Diagnostic Model for the Deficient and Excess Pulse Qualities
title_fullStr Novel Diagnostic Model for the Deficient and Excess Pulse Qualities
title_full_unstemmed Novel Diagnostic Model for the Deficient and Excess Pulse Qualities
title_short Novel Diagnostic Model for the Deficient and Excess Pulse Qualities
title_sort novel diagnostic model for the deficient and excess pulse qualities
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3167191/
https://www.ncbi.nlm.nih.gov/pubmed/21941587
http://dx.doi.org/10.1155/2012/563958
work_keys_str_mv AT kimjaeuku noveldiagnosticmodelforthedeficientandexcesspulsequalities
AT jeonyoungju noveldiagnosticmodelforthedeficientandexcesspulsequalities
AT kimyoungmin noveldiagnosticmodelforthedeficientandexcesspulsequalities
AT leehaejung noveldiagnosticmodelforthedeficientandexcesspulsequalities
AT kimjongyeol noveldiagnosticmodelforthedeficientandexcesspulsequalities