Cargando…

Single-sensor system for spatially resolved, continuous, and multiparametric optical mapping of cardiac tissue

BACKGROUND: Simultaneous optical mapping of multiple electrophysiologically relevant parameters in living myocardium is desirable for integrative exploration of mechanisms underlying heart rhythm generation under normal and pathophysiologic conditions. Current multiparametric methods are technically...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Peter, Bollensdorff, Christian, Quinn, T. Alexander, Wuskell, Joseph P., Loew, Leslie M., Kohl, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3167353/
https://www.ncbi.nlm.nih.gov/pubmed/21459161
http://dx.doi.org/10.1016/j.hrthm.2011.03.061
_version_ 1782211250981175296
author Lee, Peter
Bollensdorff, Christian
Quinn, T. Alexander
Wuskell, Joseph P.
Loew, Leslie M.
Kohl, Peter
author_facet Lee, Peter
Bollensdorff, Christian
Quinn, T. Alexander
Wuskell, Joseph P.
Loew, Leslie M.
Kohl, Peter
author_sort Lee, Peter
collection PubMed
description BACKGROUND: Simultaneous optical mapping of multiple electrophysiologically relevant parameters in living myocardium is desirable for integrative exploration of mechanisms underlying heart rhythm generation under normal and pathophysiologic conditions. Current multiparametric methods are technically challenging, usually involving multiple sensors and moving parts, which contributes to high logistic and economic thresholds that prevent easy application of the technique. OBJECTIVE: The purpose of this study was to develop a simple, affordable, and effective method for spatially resolved, continuous, simultaneous, and multiparametric optical mapping of the heart, using a single camera. METHODS: We present a new method to simultaneously monitor multiple parameters using inexpensive off-the-shelf electronic components and no moving parts. The system comprises a single camera, commercially available optical filters, and light-emitting diodes (LEDs), integrated via microcontroller-based electronics for frame-accurate illumination of the tissue. For proof of principle, we illustrate measurement of four parameters, suitable for ratiometric mapping of membrane potential (di-4-ANBDQPQ) and intracellular free calcium (fura-2), in an isolated Langendorff-perfused rat heart during sinus rhythm and ectopy, induced by local electrical or mechanical stimulation. RESULTS: The pilot application demonstrates suitability of this imaging approach for heart rhythm research in the isolated heart. In addition, locally induced excitation, whether stimulated electrically or mechanically, gives rise to similar ventricular propagation patterns. CONCLUSION: Combining an affordable camera with suitable optical filters and microprocessor-controlled LEDs, single-sensor multiparametric optical mapping can be practically implemented in a simple yet powerful configuration and applied to heart rhythm research. The moderate system complexity and component cost is destined to lower the threshold to broader application of functional imaging and to ease implementation of more complex optical mapping approaches, such as multiparametric panoramic imaging. A proof-of-principle application confirmed that although electrically and mechanically induced excitation occur by different mechanisms, their electrophysiologic consequences downstream from the point of activation are not dissimilar.
format Online
Article
Text
id pubmed-3167353
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-31673532011-09-26 Single-sensor system for spatially resolved, continuous, and multiparametric optical mapping of cardiac tissue Lee, Peter Bollensdorff, Christian Quinn, T. Alexander Wuskell, Joseph P. Loew, Leslie M. Kohl, Peter Heart Rhythm Regular Issue BACKGROUND: Simultaneous optical mapping of multiple electrophysiologically relevant parameters in living myocardium is desirable for integrative exploration of mechanisms underlying heart rhythm generation under normal and pathophysiologic conditions. Current multiparametric methods are technically challenging, usually involving multiple sensors and moving parts, which contributes to high logistic and economic thresholds that prevent easy application of the technique. OBJECTIVE: The purpose of this study was to develop a simple, affordable, and effective method for spatially resolved, continuous, simultaneous, and multiparametric optical mapping of the heart, using a single camera. METHODS: We present a new method to simultaneously monitor multiple parameters using inexpensive off-the-shelf electronic components and no moving parts. The system comprises a single camera, commercially available optical filters, and light-emitting diodes (LEDs), integrated via microcontroller-based electronics for frame-accurate illumination of the tissue. For proof of principle, we illustrate measurement of four parameters, suitable for ratiometric mapping of membrane potential (di-4-ANBDQPQ) and intracellular free calcium (fura-2), in an isolated Langendorff-perfused rat heart during sinus rhythm and ectopy, induced by local electrical or mechanical stimulation. RESULTS: The pilot application demonstrates suitability of this imaging approach for heart rhythm research in the isolated heart. In addition, locally induced excitation, whether stimulated electrically or mechanically, gives rise to similar ventricular propagation patterns. CONCLUSION: Combining an affordable camera with suitable optical filters and microprocessor-controlled LEDs, single-sensor multiparametric optical mapping can be practically implemented in a simple yet powerful configuration and applied to heart rhythm research. The moderate system complexity and component cost is destined to lower the threshold to broader application of functional imaging and to ease implementation of more complex optical mapping approaches, such as multiparametric panoramic imaging. A proof-of-principle application confirmed that although electrically and mechanically induced excitation occur by different mechanisms, their electrophysiologic consequences downstream from the point of activation are not dissimilar. Elsevier 2011-09 /pmc/articles/PMC3167353/ /pubmed/21459161 http://dx.doi.org/10.1016/j.hrthm.2011.03.061 Text en © 2011 Elsevier Inc. https://creativecommons.org/licenses/by/4.0/ Open Access under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/) license
spellingShingle Regular Issue
Lee, Peter
Bollensdorff, Christian
Quinn, T. Alexander
Wuskell, Joseph P.
Loew, Leslie M.
Kohl, Peter
Single-sensor system for spatially resolved, continuous, and multiparametric optical mapping of cardiac tissue
title Single-sensor system for spatially resolved, continuous, and multiparametric optical mapping of cardiac tissue
title_full Single-sensor system for spatially resolved, continuous, and multiparametric optical mapping of cardiac tissue
title_fullStr Single-sensor system for spatially resolved, continuous, and multiparametric optical mapping of cardiac tissue
title_full_unstemmed Single-sensor system for spatially resolved, continuous, and multiparametric optical mapping of cardiac tissue
title_short Single-sensor system for spatially resolved, continuous, and multiparametric optical mapping of cardiac tissue
title_sort single-sensor system for spatially resolved, continuous, and multiparametric optical mapping of cardiac tissue
topic Regular Issue
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3167353/
https://www.ncbi.nlm.nih.gov/pubmed/21459161
http://dx.doi.org/10.1016/j.hrthm.2011.03.061
work_keys_str_mv AT leepeter singlesensorsystemforspatiallyresolvedcontinuousandmultiparametricopticalmappingofcardiactissue
AT bollensdorffchristian singlesensorsystemforspatiallyresolvedcontinuousandmultiparametricopticalmappingofcardiactissue
AT quinntalexander singlesensorsystemforspatiallyresolvedcontinuousandmultiparametricopticalmappingofcardiactissue
AT wuskelljosephp singlesensorsystemforspatiallyresolvedcontinuousandmultiparametricopticalmappingofcardiactissue
AT loewlesliem singlesensorsystemforspatiallyresolvedcontinuousandmultiparametricopticalmappingofcardiactissue
AT kohlpeter singlesensorsystemforspatiallyresolvedcontinuousandmultiparametricopticalmappingofcardiactissue