Cargando…

Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics

BACKGROUND: The performance of glaucoma diagnostic systems could be conceivably improved by the integration of functional and structural test measurements that provide relevant and complementary information for reaching a diagnosis. The purpose of this study was to investigate the performance of dat...

Descripción completa

Detalles Bibliográficos
Autores principales: Bizios, Dimitrios, Heijl, Anders, Bengtsson, Boel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3167760/
https://www.ncbi.nlm.nih.gov/pubmed/21816080
http://dx.doi.org/10.1186/1471-2415-11-20
_version_ 1782211279474130944
author Bizios, Dimitrios
Heijl, Anders
Bengtsson, Boel
author_facet Bizios, Dimitrios
Heijl, Anders
Bengtsson, Boel
author_sort Bizios, Dimitrios
collection PubMed
description BACKGROUND: The performance of glaucoma diagnostic systems could be conceivably improved by the integration of functional and structural test measurements that provide relevant and complementary information for reaching a diagnosis. The purpose of this study was to investigate the performance of data fusion methods and techniques for simple combination of Standard Automated Perimetry (SAP) and Optical Coherence Tomography (OCT) data for the diagnosis of glaucoma using Artificial Neural Networks (ANNs). METHODS: Humphrey 24-2 SITA standard SAP and StratusOCT tests were prospectively collected from a randomly selected population of 125 healthy persons and 135 patients with glaucomatous optic nerve heads and used as input for the ANNs. We tested commercially available standard parameters as well as novel ones (fused OCT and SAP data) that exploit the spatial relationship between visual field areas and sectors of the OCT peripapillary scan circle. We evaluated the performance of these SAP and OCT derived parameters both separately and in combination. RESULTS: The diagnostic accuracy from a combination of fused SAP and OCT data (95.39%) was higher than that of the best conventional parameters of either instrument, i.e. SAP Glaucoma Hemifield Test (p < 0.001) and OCT Retinal Nerve Fiber Layer Thickness ≥ 1 quadrant (p = 0.031). Fused OCT and combined fused OCT and SAP data provided similar Area under the Receiver Operating Characteristic Curve (AROC) values of 0.978 that were significantly larger (p = 0.047) compared to ANNs using SAP parameters alone (AROC = 0.945). On the other hand, ANNs based on the OCT parameters (AROC = 0.970) did not perform significantly worse than the ANNs based on the fused or combined forms of input data. The use of fused input increased the number of tests that were correctly classified by both SAP and OCT based ANNs. CONCLUSIONS: Compared to the use of SAP parameters, input from the combination of fused OCT and SAP parameters, and from fused OCT data, significantly increased the performance of ANNs. Integrating parameters by including a priori relevant information through data fusion may improve ANN classification accuracy compared to currently available methods.
format Online
Article
Text
id pubmed-3167760
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31677602011-09-07 Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics Bizios, Dimitrios Heijl, Anders Bengtsson, Boel BMC Ophthalmol Research Article BACKGROUND: The performance of glaucoma diagnostic systems could be conceivably improved by the integration of functional and structural test measurements that provide relevant and complementary information for reaching a diagnosis. The purpose of this study was to investigate the performance of data fusion methods and techniques for simple combination of Standard Automated Perimetry (SAP) and Optical Coherence Tomography (OCT) data for the diagnosis of glaucoma using Artificial Neural Networks (ANNs). METHODS: Humphrey 24-2 SITA standard SAP and StratusOCT tests were prospectively collected from a randomly selected population of 125 healthy persons and 135 patients with glaucomatous optic nerve heads and used as input for the ANNs. We tested commercially available standard parameters as well as novel ones (fused OCT and SAP data) that exploit the spatial relationship between visual field areas and sectors of the OCT peripapillary scan circle. We evaluated the performance of these SAP and OCT derived parameters both separately and in combination. RESULTS: The diagnostic accuracy from a combination of fused SAP and OCT data (95.39%) was higher than that of the best conventional parameters of either instrument, i.e. SAP Glaucoma Hemifield Test (p < 0.001) and OCT Retinal Nerve Fiber Layer Thickness ≥ 1 quadrant (p = 0.031). Fused OCT and combined fused OCT and SAP data provided similar Area under the Receiver Operating Characteristic Curve (AROC) values of 0.978 that were significantly larger (p = 0.047) compared to ANNs using SAP parameters alone (AROC = 0.945). On the other hand, ANNs based on the OCT parameters (AROC = 0.970) did not perform significantly worse than the ANNs based on the fused or combined forms of input data. The use of fused input increased the number of tests that were correctly classified by both SAP and OCT based ANNs. CONCLUSIONS: Compared to the use of SAP parameters, input from the combination of fused OCT and SAP parameters, and from fused OCT data, significantly increased the performance of ANNs. Integrating parameters by including a priori relevant information through data fusion may improve ANN classification accuracy compared to currently available methods. BioMed Central 2011-08-04 /pmc/articles/PMC3167760/ /pubmed/21816080 http://dx.doi.org/10.1186/1471-2415-11-20 Text en Copyright ©2011 Bizios et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Bizios, Dimitrios
Heijl, Anders
Bengtsson, Boel
Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
title Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
title_full Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
title_fullStr Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
title_full_unstemmed Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
title_short Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
title_sort integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3167760/
https://www.ncbi.nlm.nih.gov/pubmed/21816080
http://dx.doi.org/10.1186/1471-2415-11-20
work_keys_str_mv AT biziosdimitrios integrationandfusionofstandardautomatedperimetryandopticalcoherencetomographydataforimprovedautomatedglaucomadiagnostics
AT heijlanders integrationandfusionofstandardautomatedperimetryandopticalcoherencetomographydataforimprovedautomatedglaucomadiagnostics
AT bengtssonboel integrationandfusionofstandardautomatedperimetryandopticalcoherencetomographydataforimprovedautomatedglaucomadiagnostics