Cargando…
Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates
PURPOSE: To evaluate the incidence of extrahepatic deposition of technetium-99m–labeled albumin macroaggregates ((99m)Tc-MAA) after pretreatment angiography, before yttrium-90 radioembolizaton ((90)Y-RE), and to report on technical solutions that can be used to ensure safe delivery of (90)Y-microsph...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3170462/ https://www.ncbi.nlm.nih.gov/pubmed/21191588 http://dx.doi.org/10.1007/s00270-010-0088-4 |
_version_ | 1782211628794642432 |
---|---|
author | Barentsz, M. W. Vente, M. A. D. Lam, M. G. E. H. Smits, M. L. J. Nijsen, J. F. W. Seinstra, B. A. Rosenbaum, C. E. N. M. Verkooijen, H. M. Zonnenberg, B. A. Van den Bosch, M. A. A. J. |
author_facet | Barentsz, M. W. Vente, M. A. D. Lam, M. G. E. H. Smits, M. L. J. Nijsen, J. F. W. Seinstra, B. A. Rosenbaum, C. E. N. M. Verkooijen, H. M. Zonnenberg, B. A. Van den Bosch, M. A. A. J. |
author_sort | Barentsz, M. W. |
collection | PubMed |
description | PURPOSE: To evaluate the incidence of extrahepatic deposition of technetium-99m–labeled albumin macroaggregates ((99m)Tc-MAA) after pretreatment angiography, before yttrium-90 radioembolizaton ((90)Y-RE), and to report on technical solutions that can be used to ensure safe delivery of (90)Y-microspheres in patients with initial extrahepatic deposition. MATERIALS AND METHODS: A retrospective analysis of 26 patients with primary and secondary liver malignancies, who were scheduled for treatment with (90)Y-RE in our institution in 2009, was performed. The angiograms and single-photon emission computed tomography images of all patients were reviewed by an interventional radiologist and a nuclear medicine physician, respectively, to identify and localize extrahepatic deposition of (99m)Tc-MAA when present. Subsequently, the technical solutions were used to successfully perform (90)Y-RE in these patients were evaluated and described. RESULTS: Extrahepatic deposition of (99m)Tc-MAA was observed in 8 of 26 patients (31%). In 7 of 8 patients, a second pretreatment angiography was performed to detect the cause of extrahepatic deposition. The technical solutions to enable safe (90)Y microspheres delivery included more distal placement of the microcatheter in the proper/right hepatic artery in 4 of 7 (57%) patients; (super)selective catheterization of multiple segmental branches in 2 of 7 (29%); and additional coiling of a newly detected branch in the remaining patient (14%). This was confirmed by a second MAA procedure. (90)Y-RE was eventually performed in 25 of 26 (96%) patients. No procedure-related complications (<30 days) were observed. CONCLUSION: Extrahepatic deposition of (99m)Tc-MAA after pretreatment angiography did occur in 8 of 26 (31%) patients. The technical solutions as presented allowed safe (90)Y-RE delivery in 25 of 26 (96%) patients. |
format | Online Article Text |
id | pubmed-3170462 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-31704622011-09-26 Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates Barentsz, M. W. Vente, M. A. D. Lam, M. G. E. H. Smits, M. L. J. Nijsen, J. F. W. Seinstra, B. A. Rosenbaum, C. E. N. M. Verkooijen, H. M. Zonnenberg, B. A. Van den Bosch, M. A. A. J. Cardiovasc Intervent Radiol Technical Note PURPOSE: To evaluate the incidence of extrahepatic deposition of technetium-99m–labeled albumin macroaggregates ((99m)Tc-MAA) after pretreatment angiography, before yttrium-90 radioembolizaton ((90)Y-RE), and to report on technical solutions that can be used to ensure safe delivery of (90)Y-microspheres in patients with initial extrahepatic deposition. MATERIALS AND METHODS: A retrospective analysis of 26 patients with primary and secondary liver malignancies, who were scheduled for treatment with (90)Y-RE in our institution in 2009, was performed. The angiograms and single-photon emission computed tomography images of all patients were reviewed by an interventional radiologist and a nuclear medicine physician, respectively, to identify and localize extrahepatic deposition of (99m)Tc-MAA when present. Subsequently, the technical solutions were used to successfully perform (90)Y-RE in these patients were evaluated and described. RESULTS: Extrahepatic deposition of (99m)Tc-MAA was observed in 8 of 26 patients (31%). In 7 of 8 patients, a second pretreatment angiography was performed to detect the cause of extrahepatic deposition. The technical solutions to enable safe (90)Y microspheres delivery included more distal placement of the microcatheter in the proper/right hepatic artery in 4 of 7 (57%) patients; (super)selective catheterization of multiple segmental branches in 2 of 7 (29%); and additional coiling of a newly detected branch in the remaining patient (14%). This was confirmed by a second MAA procedure. (90)Y-RE was eventually performed in 25 of 26 (96%) patients. No procedure-related complications (<30 days) were observed. CONCLUSION: Extrahepatic deposition of (99m)Tc-MAA after pretreatment angiography did occur in 8 of 26 (31%) patients. The technical solutions as presented allowed safe (90)Y-RE delivery in 25 of 26 (96%) patients. Springer-Verlag 2010-12-30 2011 /pmc/articles/PMC3170462/ /pubmed/21191588 http://dx.doi.org/10.1007/s00270-010-0088-4 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Technical Note Barentsz, M. W. Vente, M. A. D. Lam, M. G. E. H. Smits, M. L. J. Nijsen, J. F. W. Seinstra, B. A. Rosenbaum, C. E. N. M. Verkooijen, H. M. Zonnenberg, B. A. Van den Bosch, M. A. A. J. Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates |
title | Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates |
title_full | Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates |
title_fullStr | Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates |
title_full_unstemmed | Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates |
title_short | Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates |
title_sort | technical solutions to ensure safe yttrium-90 radioembolization in patients with initial extrahepatic deposition of (99m)technetium–albumin macroaggregates |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3170462/ https://www.ncbi.nlm.nih.gov/pubmed/21191588 http://dx.doi.org/10.1007/s00270-010-0088-4 |
work_keys_str_mv | AT barentszmw technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates AT ventemad technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates AT lammgeh technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates AT smitsmlj technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates AT nijsenjfw technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates AT seinstraba technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates AT rosenbaumcenm technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates AT verkooijenhm technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates AT zonnenbergba technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates AT vandenboschmaaj technicalsolutionstoensuresafeyttrium90radioembolizationinpatientswithinitialextrahepaticdepositionof99mtechnetiumalbuminmacroaggregates |