Cargando…

Role of Trabecular Microarchitecture and Its Heterogeneity Parameters in the Mechanical Behavior of Ex Vivo Human L(3) Vertebrae

Low bone mineral density (BMD) is a strong risk factor for vertebral fracture risk in osteoporosis. However, many fractures occur in people with moderately decreased or normal BMD. Our aim was to assess the contributions of trabecular microarchitecture and its heterogeneity to the mechanical behavio...

Descripción completa

Detalles Bibliográficos
Autores principales: Wegrzyn, Julien, Roux, Jean-Paul, Arlot, Monique E, Boutroy, Stéphanie, Vilayphiou, Nicolas, Guyen, Olivier, Delmas, Pierre D, Chapurlat, Roland, Bouxsein, Mary L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wiley Subscription Services, Inc., A Wiley Company 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3179283/
https://www.ncbi.nlm.nih.gov/pubmed/20564249
http://dx.doi.org/10.1002/jbmr.164
_version_ 1782212497955094528
author Wegrzyn, Julien
Roux, Jean-Paul
Arlot, Monique E
Boutroy, Stéphanie
Vilayphiou, Nicolas
Guyen, Olivier
Delmas, Pierre D
Chapurlat, Roland
Bouxsein, Mary L
author_facet Wegrzyn, Julien
Roux, Jean-Paul
Arlot, Monique E
Boutroy, Stéphanie
Vilayphiou, Nicolas
Guyen, Olivier
Delmas, Pierre D
Chapurlat, Roland
Bouxsein, Mary L
author_sort Wegrzyn, Julien
collection PubMed
description Low bone mineral density (BMD) is a strong risk factor for vertebral fracture risk in osteoporosis. However, many fractures occur in people with moderately decreased or normal BMD. Our aim was to assess the contributions of trabecular microarchitecture and its heterogeneity to the mechanical behavior of human lumbar vertebrae. Twenty-one human L(3) vertebrae were analyzed for BMD by dual-energy X-ray absorptiometry (DXA) and microarchitecture by high-resolution peripheral quantitative computed tomography (HR-pQCT) and then tested in axial compression. Microarchitecture heterogeneity was assessed using two vertically oriented virtual biopsies—one anterior (Ant) and one posterior (Post)—each divided into three zones (superior, middle, and inferior) and using the whole vertebral trabecular volume for the intraindividual distribution of trabecular separation (Tb.Sp*SD). Heterogeneity parameters were defined as (1) ratios of anterior to posterior microarchitectural parameters and (2) the coefficient of variation of microarchitectural parameters from the superior, middle, and inferior zones. BMD alone explained up to 44% of the variability in vertebral mechanical behavior, bone volume fraction (BV/TV) up to 53%, and trabecular architecture up to 66%. Importantly, bone mass (BMD or BV/TV) in combination with microarchitecture and its heterogeneity improved the prediction of vertebral mechanical behavior, together explaining up to 86% of the variability in vertebral failure load. In conclusion, our data indicate that regional variation of microarchitecture assessment expressed by heterogeneity parameters may enhance prediction of vertebral fracture risk. © 2010 American Society for Bone and Mineral Research.
format Online
Article
Text
id pubmed-3179283
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Wiley Subscription Services, Inc., A Wiley Company
record_format MEDLINE/PubMed
spelling pubmed-31792832011-11-01 Role of Trabecular Microarchitecture and Its Heterogeneity Parameters in the Mechanical Behavior of Ex Vivo Human L(3) Vertebrae Wegrzyn, Julien Roux, Jean-Paul Arlot, Monique E Boutroy, Stéphanie Vilayphiou, Nicolas Guyen, Olivier Delmas, Pierre D Chapurlat, Roland Bouxsein, Mary L J Bone Miner Res Original Article Low bone mineral density (BMD) is a strong risk factor for vertebral fracture risk in osteoporosis. However, many fractures occur in people with moderately decreased or normal BMD. Our aim was to assess the contributions of trabecular microarchitecture and its heterogeneity to the mechanical behavior of human lumbar vertebrae. Twenty-one human L(3) vertebrae were analyzed for BMD by dual-energy X-ray absorptiometry (DXA) and microarchitecture by high-resolution peripheral quantitative computed tomography (HR-pQCT) and then tested in axial compression. Microarchitecture heterogeneity was assessed using two vertically oriented virtual biopsies—one anterior (Ant) and one posterior (Post)—each divided into three zones (superior, middle, and inferior) and using the whole vertebral trabecular volume for the intraindividual distribution of trabecular separation (Tb.Sp*SD). Heterogeneity parameters were defined as (1) ratios of anterior to posterior microarchitectural parameters and (2) the coefficient of variation of microarchitectural parameters from the superior, middle, and inferior zones. BMD alone explained up to 44% of the variability in vertebral mechanical behavior, bone volume fraction (BV/TV) up to 53%, and trabecular architecture up to 66%. Importantly, bone mass (BMD or BV/TV) in combination with microarchitecture and its heterogeneity improved the prediction of vertebral mechanical behavior, together explaining up to 86% of the variability in vertebral failure load. In conclusion, our data indicate that regional variation of microarchitecture assessment expressed by heterogeneity parameters may enhance prediction of vertebral fracture risk. © 2010 American Society for Bone and Mineral Research. Wiley Subscription Services, Inc., A Wiley Company 2010-11 2010-06-18 /pmc/articles/PMC3179283/ /pubmed/20564249 http://dx.doi.org/10.1002/jbmr.164 Text en Copyright © 2010 American Society for Bone and Mineral Research http://creativecommons.org/licenses/by/2.5/ Re-use of this article is permitted in accordance with the Creative Commons Deed, Attribution 2.5, which does not permit commercial exploitation.
spellingShingle Original Article
Wegrzyn, Julien
Roux, Jean-Paul
Arlot, Monique E
Boutroy, Stéphanie
Vilayphiou, Nicolas
Guyen, Olivier
Delmas, Pierre D
Chapurlat, Roland
Bouxsein, Mary L
Role of Trabecular Microarchitecture and Its Heterogeneity Parameters in the Mechanical Behavior of Ex Vivo Human L(3) Vertebrae
title Role of Trabecular Microarchitecture and Its Heterogeneity Parameters in the Mechanical Behavior of Ex Vivo Human L(3) Vertebrae
title_full Role of Trabecular Microarchitecture and Its Heterogeneity Parameters in the Mechanical Behavior of Ex Vivo Human L(3) Vertebrae
title_fullStr Role of Trabecular Microarchitecture and Its Heterogeneity Parameters in the Mechanical Behavior of Ex Vivo Human L(3) Vertebrae
title_full_unstemmed Role of Trabecular Microarchitecture and Its Heterogeneity Parameters in the Mechanical Behavior of Ex Vivo Human L(3) Vertebrae
title_short Role of Trabecular Microarchitecture and Its Heterogeneity Parameters in the Mechanical Behavior of Ex Vivo Human L(3) Vertebrae
title_sort role of trabecular microarchitecture and its heterogeneity parameters in the mechanical behavior of ex vivo human l(3) vertebrae
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3179283/
https://www.ncbi.nlm.nih.gov/pubmed/20564249
http://dx.doi.org/10.1002/jbmr.164
work_keys_str_mv AT wegrzynjulien roleoftrabecularmicroarchitectureanditsheterogeneityparametersinthemechanicalbehaviorofexvivohumanl3vertebrae
AT rouxjeanpaul roleoftrabecularmicroarchitectureanditsheterogeneityparametersinthemechanicalbehaviorofexvivohumanl3vertebrae
AT arlotmoniquee roleoftrabecularmicroarchitectureanditsheterogeneityparametersinthemechanicalbehaviorofexvivohumanl3vertebrae
AT boutroystephanie roleoftrabecularmicroarchitectureanditsheterogeneityparametersinthemechanicalbehaviorofexvivohumanl3vertebrae
AT vilayphiounicolas roleoftrabecularmicroarchitectureanditsheterogeneityparametersinthemechanicalbehaviorofexvivohumanl3vertebrae
AT guyenolivier roleoftrabecularmicroarchitectureanditsheterogeneityparametersinthemechanicalbehaviorofexvivohumanl3vertebrae
AT delmaspierred roleoftrabecularmicroarchitectureanditsheterogeneityparametersinthemechanicalbehaviorofexvivohumanl3vertebrae
AT chapurlatroland roleoftrabecularmicroarchitectureanditsheterogeneityparametersinthemechanicalbehaviorofexvivohumanl3vertebrae
AT bouxseinmaryl roleoftrabecularmicroarchitectureanditsheterogeneityparametersinthemechanicalbehaviorofexvivohumanl3vertebrae