Cargando…

Estimation of radiation dose received by the radiation worker during F-18 FDG injection process

BACKGROUND: The radiation dosimetric literature concerning the medical and non-medical personnel working in nuclear medicine departments are limited, particularly radiation doses received by radiation worker in nuclear medicine department during positron emission tomography (PET) radiopharmaceutical...

Descripción completa

Detalles Bibliográficos
Autores principales: Jha, Ashish Kumar, Zade, Anand, Rangarajan, Venkatesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3180714/
https://www.ncbi.nlm.nih.gov/pubmed/21969773
http://dx.doi.org/10.4103/0972-3919.84591
_version_ 1782212684685508608
author Jha, Ashish Kumar
Zade, Anand
Rangarajan, Venkatesh
author_facet Jha, Ashish Kumar
Zade, Anand
Rangarajan, Venkatesh
author_sort Jha, Ashish Kumar
collection PubMed
description BACKGROUND: The radiation dosimetric literature concerning the medical and non-medical personnel working in nuclear medicine departments are limited, particularly radiation doses received by radiation worker in nuclear medicine department during positron emission tomography (PET) radiopharmaceutical injection process. This is of interest and concern for the personnel. AIM: To measure the radiation dose received by the staff involved in injection process of Fluorine-18 Fluorodeoxyglucose (FDG). MATERIALS AND METHODS: The effective whole body doses to the radiation workers involved in injections of 1511 patients over a period of 10 weeks were evaluated using pocket dosimeter. Each patient was injected with 5 MBq/kg of F-18 FDG. The F18-FDG injection protocol followed in our department is as follows. The technologist dispenses the dose to be injected and records the pre-injection activity. The nursing staff members then secure an intravenous catheter. The nuclear medicine physicians/residents inject the dose on a rotation basis in accordance with ALARA principle. After the injection of the tracer, the nursing staff members flush the intravenous catheter. The person who injected the tracer then measures the post-injection residual dose in the syringe. RESULTS: The mean effective whole body doses per injection for the staff were the following: Nurses received 1.44±0.22 μSv/injection (3.71±0.48 nSv/MBq), for doctors the dose values were 2.44±0.25 μSv/injection (6.29±0.49 nSv/MBq) and for technologists the doses were 0.61±0.10 μSv/injection (1.58±0.21 nSv/MBq). It was seen that the mean effective whole body dose per injection of our positron emission tomography/computed tomography (PET/CT) staff who were involved in the F18-FDG injection process was maximum for doctors (54.34% differential doses), followed by nurses (32.02% differential doses) and technologist (13.64% differential doses). CONCLUSION: This study confirms that low levels of radiation dose are received by staff during F18-FDG injection and these values can be used as a reference to allay any anxiety in the radiation workers.
format Online
Article
Text
id pubmed-3180714
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-31807142011-10-03 Estimation of radiation dose received by the radiation worker during F-18 FDG injection process Jha, Ashish Kumar Zade, Anand Rangarajan, Venkatesh Indian J Nucl Med Original Article BACKGROUND: The radiation dosimetric literature concerning the medical and non-medical personnel working in nuclear medicine departments are limited, particularly radiation doses received by radiation worker in nuclear medicine department during positron emission tomography (PET) radiopharmaceutical injection process. This is of interest and concern for the personnel. AIM: To measure the radiation dose received by the staff involved in injection process of Fluorine-18 Fluorodeoxyglucose (FDG). MATERIALS AND METHODS: The effective whole body doses to the radiation workers involved in injections of 1511 patients over a period of 10 weeks were evaluated using pocket dosimeter. Each patient was injected with 5 MBq/kg of F-18 FDG. The F18-FDG injection protocol followed in our department is as follows. The technologist dispenses the dose to be injected and records the pre-injection activity. The nursing staff members then secure an intravenous catheter. The nuclear medicine physicians/residents inject the dose on a rotation basis in accordance with ALARA principle. After the injection of the tracer, the nursing staff members flush the intravenous catheter. The person who injected the tracer then measures the post-injection residual dose in the syringe. RESULTS: The mean effective whole body doses per injection for the staff were the following: Nurses received 1.44±0.22 μSv/injection (3.71±0.48 nSv/MBq), for doctors the dose values were 2.44±0.25 μSv/injection (6.29±0.49 nSv/MBq) and for technologists the doses were 0.61±0.10 μSv/injection (1.58±0.21 nSv/MBq). It was seen that the mean effective whole body dose per injection of our positron emission tomography/computed tomography (PET/CT) staff who were involved in the F18-FDG injection process was maximum for doctors (54.34% differential doses), followed by nurses (32.02% differential doses) and technologist (13.64% differential doses). CONCLUSION: This study confirms that low levels of radiation dose are received by staff during F18-FDG injection and these values can be used as a reference to allay any anxiety in the radiation workers. Medknow Publications 2011 /pmc/articles/PMC3180714/ /pubmed/21969773 http://dx.doi.org/10.4103/0972-3919.84591 Text en Copyright: © Indian Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jha, Ashish Kumar
Zade, Anand
Rangarajan, Venkatesh
Estimation of radiation dose received by the radiation worker during F-18 FDG injection process
title Estimation of radiation dose received by the radiation worker during F-18 FDG injection process
title_full Estimation of radiation dose received by the radiation worker during F-18 FDG injection process
title_fullStr Estimation of radiation dose received by the radiation worker during F-18 FDG injection process
title_full_unstemmed Estimation of radiation dose received by the radiation worker during F-18 FDG injection process
title_short Estimation of radiation dose received by the radiation worker during F-18 FDG injection process
title_sort estimation of radiation dose received by the radiation worker during f-18 fdg injection process
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3180714/
https://www.ncbi.nlm.nih.gov/pubmed/21969773
http://dx.doi.org/10.4103/0972-3919.84591
work_keys_str_mv AT jhaashishkumar estimationofradiationdosereceivedbytheradiationworkerduringf18fdginjectionprocess
AT zadeanand estimationofradiationdosereceivedbytheradiationworkerduringf18fdginjectionprocess
AT rangarajanvenkatesh estimationofradiationdosereceivedbytheradiationworkerduringf18fdginjectionprocess