Cargando…
Videodensitometric analysis of advanced carotid plaque: correlation with MMP-9 and TIMP-1 expression
BACKGROUND: Matrix metalloproteinase-9 (MMP-9) and tissue inhibitor of MMP (TIMP) promote derangement of the extracellular matrix, which is ultimately reflected in plaque images seen on ultrasound. Videodensitometry can identify structural disturbances in plaques. OBJECTIVES: To establish the correl...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3182957/ https://www.ncbi.nlm.nih.gov/pubmed/21923935 http://dx.doi.org/10.1186/1476-7120-9-24 |
_version_ | 1782212954828046336 |
---|---|
author | Baroncini, Liz Andréa V Filho Pazin, Antonio Murta Junior, Luiz Otávio Nakao, Lia S Ramos, Simone G Précoma, Dalton B |
author_facet | Baroncini, Liz Andréa V Filho Pazin, Antonio Murta Junior, Luiz Otávio Nakao, Lia S Ramos, Simone G Précoma, Dalton B |
author_sort | Baroncini, Liz Andréa V |
collection | PubMed |
description | BACKGROUND: Matrix metalloproteinase-9 (MMP-9) and tissue inhibitor of MMP (TIMP) promote derangement of the extracellular matrix, which is ultimately reflected in plaque images seen on ultrasound. Videodensitometry can identify structural disturbances in plaques. OBJECTIVES: To establish the correlations between values determined using videodensitometry in B-mode ultrasound images of advanced carotid plaques and the total expression of MMP-9 and TIMP-1 in these removed plaques. METHODS: Thirty patients underwent ultrasonic tissue characterization of carotid plaques before surgery, using mean gray level (MGL), energy, entropy and homogeneity. Each patient was assigned preoperatively to one of 2 groups: group I, symptomatic patients (n = 16; 12 males; mean age 66.7 ± 6.8 years), and group II, asymptomatic patients (n = 14; 8 males; mean age 67.6 ± 6.81 years). Tissue specimens were analyzed for MMP-9 and TIMP-1 expression. Nine carotid arteries were used as normal tissue controls. RESULTS: MMP-9 expression levels were elevated in group II and in normal tissues compared to group I (p < 0.001). TIMP-1 levels were higher in group II than in group I, and significantly higher in normal tissues than in group I (p = 0.039). The MGL was higher in group II compared to group I (p = 0.038). Energy had greater values in group II compared to group I (p = 0.02). There were no differences between patient groups in homogeneity and entropy. Energy positively correlated with MMP-9 and TIMP-1 expression (p = 0.012 and p = 0.031 respectively). Homogeneity positively correlated with MMP-9 and TIMP-1 expression (p = 0.034 and p = 0.047 respectively). There were no correlations between protein expression and MGL or entropy. CONCLUSIONS: Videodensitometric computer analysis of ultrasound scanning images can be used to identify stable carotid plaques, which have higher total expression levels of MMP-9 and TIMP-1 than unstable plaques. |
format | Online Article Text |
id | pubmed-3182957 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-31829572011-09-30 Videodensitometric analysis of advanced carotid plaque: correlation with MMP-9 and TIMP-1 expression Baroncini, Liz Andréa V Filho Pazin, Antonio Murta Junior, Luiz Otávio Nakao, Lia S Ramos, Simone G Précoma, Dalton B Cardiovasc Ultrasound Research BACKGROUND: Matrix metalloproteinase-9 (MMP-9) and tissue inhibitor of MMP (TIMP) promote derangement of the extracellular matrix, which is ultimately reflected in plaque images seen on ultrasound. Videodensitometry can identify structural disturbances in plaques. OBJECTIVES: To establish the correlations between values determined using videodensitometry in B-mode ultrasound images of advanced carotid plaques and the total expression of MMP-9 and TIMP-1 in these removed plaques. METHODS: Thirty patients underwent ultrasonic tissue characterization of carotid plaques before surgery, using mean gray level (MGL), energy, entropy and homogeneity. Each patient was assigned preoperatively to one of 2 groups: group I, symptomatic patients (n = 16; 12 males; mean age 66.7 ± 6.8 years), and group II, asymptomatic patients (n = 14; 8 males; mean age 67.6 ± 6.81 years). Tissue specimens were analyzed for MMP-9 and TIMP-1 expression. Nine carotid arteries were used as normal tissue controls. RESULTS: MMP-9 expression levels were elevated in group II and in normal tissues compared to group I (p < 0.001). TIMP-1 levels were higher in group II than in group I, and significantly higher in normal tissues than in group I (p = 0.039). The MGL was higher in group II compared to group I (p = 0.038). Energy had greater values in group II compared to group I (p = 0.02). There were no differences between patient groups in homogeneity and entropy. Energy positively correlated with MMP-9 and TIMP-1 expression (p = 0.012 and p = 0.031 respectively). Homogeneity positively correlated with MMP-9 and TIMP-1 expression (p = 0.034 and p = 0.047 respectively). There were no correlations between protein expression and MGL or entropy. CONCLUSIONS: Videodensitometric computer analysis of ultrasound scanning images can be used to identify stable carotid plaques, which have higher total expression levels of MMP-9 and TIMP-1 than unstable plaques. BioMed Central 2011-09-18 /pmc/articles/PMC3182957/ /pubmed/21923935 http://dx.doi.org/10.1186/1476-7120-9-24 Text en Copyright ©2011 Baroncini et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Baroncini, Liz Andréa V Filho Pazin, Antonio Murta Junior, Luiz Otávio Nakao, Lia S Ramos, Simone G Précoma, Dalton B Videodensitometric analysis of advanced carotid plaque: correlation with MMP-9 and TIMP-1 expression |
title | Videodensitometric analysis of advanced carotid plaque: correlation with MMP-9 and TIMP-1 expression |
title_full | Videodensitometric analysis of advanced carotid plaque: correlation with MMP-9 and TIMP-1 expression |
title_fullStr | Videodensitometric analysis of advanced carotid plaque: correlation with MMP-9 and TIMP-1 expression |
title_full_unstemmed | Videodensitometric analysis of advanced carotid plaque: correlation with MMP-9 and TIMP-1 expression |
title_short | Videodensitometric analysis of advanced carotid plaque: correlation with MMP-9 and TIMP-1 expression |
title_sort | videodensitometric analysis of advanced carotid plaque: correlation with mmp-9 and timp-1 expression |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3182957/ https://www.ncbi.nlm.nih.gov/pubmed/21923935 http://dx.doi.org/10.1186/1476-7120-9-24 |
work_keys_str_mv | AT baroncinilizandreav videodensitometricanalysisofadvancedcarotidplaquecorrelationwithmmp9andtimp1expression AT filhopazinantonio videodensitometricanalysisofadvancedcarotidplaquecorrelationwithmmp9andtimp1expression AT murtajuniorluizotavio videodensitometricanalysisofadvancedcarotidplaquecorrelationwithmmp9andtimp1expression AT nakaolias videodensitometricanalysisofadvancedcarotidplaquecorrelationwithmmp9andtimp1expression AT ramossimoneg videodensitometricanalysisofadvancedcarotidplaquecorrelationwithmmp9andtimp1expression AT precomadaltonb videodensitometricanalysisofadvancedcarotidplaquecorrelationwithmmp9andtimp1expression |