Cargando…
Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization
Ovarian cancer has the lowest survival rate of the gynecologic cancers because it is predominantly diagnosed in Stages III or IV due to the lack of reliable symptoms, as well as the lack of efficacious screening techniques. Detection before the malignancy spreads or at the early stage would greatly...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3184864/ https://www.ncbi.nlm.nih.gov/pubmed/21991547 http://dx.doi.org/10.1364/BOE.2.002551 |
_version_ | 1782213155741499392 |
---|---|
author | Yang, Yi Li, Xiang Wang, Tianheng Kumavor, Patrick D. Aguirre, Andres Shung, Kirk K. Zhou, Qifa Sanders, Melinda Brewer, Molly Zhu, Quing |
author_facet | Yang, Yi Li, Xiang Wang, Tianheng Kumavor, Patrick D. Aguirre, Andres Shung, Kirk K. Zhou, Qifa Sanders, Melinda Brewer, Molly Zhu, Quing |
author_sort | Yang, Yi |
collection | PubMed |
description | Ovarian cancer has the lowest survival rate of the gynecologic cancers because it is predominantly diagnosed in Stages III or IV due to the lack of reliable symptoms, as well as the lack of efficacious screening techniques. Detection before the malignancy spreads or at the early stage would greatly improve the survival and benefit patient health. In this report, we present an integrated optical coherence tomography (OCT), ultrasound (US) and photoacoustic imaging (PAI) prototype endoscopy system for ovarian tissue characterization. The overall diameter of the prototype endoscope is 5 mm which is suitable for insertion through a standard 5-12.5mm endoscopic laparoscopic port during minimally invasive surgery. It consists of a ball-lensed OCT sample arm probe, a multimode fiber having the output end polished at 45 degree angle so as to deliver the light perpendicularly for PAI, and a high frequency ultrasound transducer with 35MHz center frequency. System characterizations of OCT, US and PAI are presented. In addition, results obtained from ex vivo porcine and human ovarian tissues are presented. The optical absorption contrast provided by PAI, the high resolution subsurface morphology provided by OCT, and the deeper tissue structure imaged by US demonstrate the synergy of the combined endoscopy and the superior performance of this hybrid device over each modality alone in ovarian tissue characterization. |
format | Online Article Text |
id | pubmed-3184864 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-31848642011-10-11 Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization Yang, Yi Li, Xiang Wang, Tianheng Kumavor, Patrick D. Aguirre, Andres Shung, Kirk K. Zhou, Qifa Sanders, Melinda Brewer, Molly Zhu, Quing Biomed Opt Express Multimodal Imaging Ovarian cancer has the lowest survival rate of the gynecologic cancers because it is predominantly diagnosed in Stages III or IV due to the lack of reliable symptoms, as well as the lack of efficacious screening techniques. Detection before the malignancy spreads or at the early stage would greatly improve the survival and benefit patient health. In this report, we present an integrated optical coherence tomography (OCT), ultrasound (US) and photoacoustic imaging (PAI) prototype endoscopy system for ovarian tissue characterization. The overall diameter of the prototype endoscope is 5 mm which is suitable for insertion through a standard 5-12.5mm endoscopic laparoscopic port during minimally invasive surgery. It consists of a ball-lensed OCT sample arm probe, a multimode fiber having the output end polished at 45 degree angle so as to deliver the light perpendicularly for PAI, and a high frequency ultrasound transducer with 35MHz center frequency. System characterizations of OCT, US and PAI are presented. In addition, results obtained from ex vivo porcine and human ovarian tissues are presented. The optical absorption contrast provided by PAI, the high resolution subsurface morphology provided by OCT, and the deeper tissue structure imaged by US demonstrate the synergy of the combined endoscopy and the superior performance of this hybrid device over each modality alone in ovarian tissue characterization. Optical Society of America 2011-08-05 /pmc/articles/PMC3184864/ /pubmed/21991547 http://dx.doi.org/10.1364/BOE.2.002551 Text en ©2011 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Multimodal Imaging Yang, Yi Li, Xiang Wang, Tianheng Kumavor, Patrick D. Aguirre, Andres Shung, Kirk K. Zhou, Qifa Sanders, Melinda Brewer, Molly Zhu, Quing Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization |
title | Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization |
title_full | Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization |
title_fullStr | Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization |
title_full_unstemmed | Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization |
title_short | Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization |
title_sort | integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization |
topic | Multimodal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3184864/ https://www.ncbi.nlm.nih.gov/pubmed/21991547 http://dx.doi.org/10.1364/BOE.2.002551 |
work_keys_str_mv | AT yangyi integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization AT lixiang integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization AT wangtianheng integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization AT kumavorpatrickd integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization AT aguirreandres integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization AT shungkirkk integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization AT zhouqifa integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization AT sandersmelinda integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization AT brewermolly integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization AT zhuquing integratedopticalcoherencetomographyultrasoundandphotoacousticimagingforovariantissuecharacterization |