Reduced adhesion of macrophages on anodized titanium with select nanotube surface features
One of the important prerequisites for a successful orthopedic implant apart from being osteoconductive is the elicitation of a favorable immune response that does not lead to the rejection of the implant by the host tissue. Anodization is one of the simplest surface modification processes used to c...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3184936/ https://www.ncbi.nlm.nih.gov/pubmed/21980239 http://dx.doi.org/10.2147/IJN.S22763 |
_version_ | 1782213161351380992 |
---|---|
author | Rajyalakshmi, Amancherla Ercan, Batur Balasubramanian, K Webster, Thomas J |
author_facet | Rajyalakshmi, Amancherla Ercan, Batur Balasubramanian, K Webster, Thomas J |
author_sort | Rajyalakshmi, Amancherla |
collection | PubMed |
description | One of the important prerequisites for a successful orthopedic implant apart from being osteoconductive is the elicitation of a favorable immune response that does not lead to the rejection of the implant by the host tissue. Anodization is one of the simplest surface modification processes used to create nanotextured and nanotubular features on metal oxides which has been shown to improve bone formation. Anodization of titanium (Ti) leads to the formation of TiO(2) nanotubes on the surface, and the presence of these nanotubes mimics the natural nanoscale features of bone, which in turn contributes to improved bone cell attachment, migration, and proliferation. However, inflammatory cell responses on anodized Ti remains to be tested. It is hypothesized that surface roughness and surface feature size on anodized Ti can be carefully manipulated to control immune cell (specifically, macrophages) responses. Here, when Ti samples were anodized at 10 V in the presence of 1% hydrofluoric acid (HF) for 1 minute, nanotextured (nonnanotube) surfaces were created. When anodization of Ti samples was carried out with 1% HF for 10 minutes at 15 V, nanotubes with 40–50 nm diameters were formed, whereas at 20 V with 1% HF for 10 minutes, nanotubes with 60–70 nm diameters were formed. In this study, a reduced density of macrophages was observed after 24 hours of culture on nanotextured and nanotubular Ti samples which were anodized at 10, 15, and 20 V, compared with conventional unmodified Ti samples. This in vitro study thus demonstrated a reduced density of macrophages on anodized Ti, thereby providing further evidence of the greater efficacy of anodized Ti for orthopedic applications. |
format | Online Article Text |
id | pubmed-3184936 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-31849362011-10-06 Reduced adhesion of macrophages on anodized titanium with select nanotube surface features Rajyalakshmi, Amancherla Ercan, Batur Balasubramanian, K Webster, Thomas J Int J Nanomedicine Original Research One of the important prerequisites for a successful orthopedic implant apart from being osteoconductive is the elicitation of a favorable immune response that does not lead to the rejection of the implant by the host tissue. Anodization is one of the simplest surface modification processes used to create nanotextured and nanotubular features on metal oxides which has been shown to improve bone formation. Anodization of titanium (Ti) leads to the formation of TiO(2) nanotubes on the surface, and the presence of these nanotubes mimics the natural nanoscale features of bone, which in turn contributes to improved bone cell attachment, migration, and proliferation. However, inflammatory cell responses on anodized Ti remains to be tested. It is hypothesized that surface roughness and surface feature size on anodized Ti can be carefully manipulated to control immune cell (specifically, macrophages) responses. Here, when Ti samples were anodized at 10 V in the presence of 1% hydrofluoric acid (HF) for 1 minute, nanotextured (nonnanotube) surfaces were created. When anodization of Ti samples was carried out with 1% HF for 10 minutes at 15 V, nanotubes with 40–50 nm diameters were formed, whereas at 20 V with 1% HF for 10 minutes, nanotubes with 60–70 nm diameters were formed. In this study, a reduced density of macrophages was observed after 24 hours of culture on nanotextured and nanotubular Ti samples which were anodized at 10, 15, and 20 V, compared with conventional unmodified Ti samples. This in vitro study thus demonstrated a reduced density of macrophages on anodized Ti, thereby providing further evidence of the greater efficacy of anodized Ti for orthopedic applications. Dove Medical Press 2011 2011-08-23 /pmc/articles/PMC3184936/ /pubmed/21980239 http://dx.doi.org/10.2147/IJN.S22763 Text en © 2011 Rajyalakshmi et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. |
spellingShingle | Original Research Rajyalakshmi, Amancherla Ercan, Batur Balasubramanian, K Webster, Thomas J Reduced adhesion of macrophages on anodized titanium with select nanotube surface features |
title | Reduced adhesion of macrophages on anodized titanium with select nanotube surface features |
title_full | Reduced adhesion of macrophages on anodized titanium with select nanotube surface features |
title_fullStr | Reduced adhesion of macrophages on anodized titanium with select nanotube surface features |
title_full_unstemmed | Reduced adhesion of macrophages on anodized titanium with select nanotube surface features |
title_short | Reduced adhesion of macrophages on anodized titanium with select nanotube surface features |
title_sort | reduced adhesion of macrophages on anodized titanium with select nanotube surface features |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3184936/ https://www.ncbi.nlm.nih.gov/pubmed/21980239 http://dx.doi.org/10.2147/IJN.S22763 |
work_keys_str_mv | AT rajyalakshmiamancherla reducedadhesionofmacrophagesonanodizedtitaniumwithselectnanotubesurfacefeatures AT ercanbatur reducedadhesionofmacrophagesonanodizedtitaniumwithselectnanotubesurfacefeatures AT balasubramaniank reducedadhesionofmacrophagesonanodizedtitaniumwithselectnanotubesurfacefeatures AT websterthomasj reducedadhesionofmacrophagesonanodizedtitaniumwithselectnanotubesurfacefeatures |