Cargando…

Reduced adhesion of macrophages on anodized titanium with select nanotube surface features

One of the important prerequisites for a successful orthopedic implant apart from being osteoconductive is the elicitation of a favorable immune response that does not lead to the rejection of the implant by the host tissue. Anodization is one of the simplest surface modification processes used to c...

Descripción completa

Detalles Bibliográficos
Autores principales: Rajyalakshmi, Amancherla, Ercan, Batur, Balasubramanian, K, Webster, Thomas J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3184936/
https://www.ncbi.nlm.nih.gov/pubmed/21980239
http://dx.doi.org/10.2147/IJN.S22763
_version_ 1782213161351380992
author Rajyalakshmi, Amancherla
Ercan, Batur
Balasubramanian, K
Webster, Thomas J
author_facet Rajyalakshmi, Amancherla
Ercan, Batur
Balasubramanian, K
Webster, Thomas J
author_sort Rajyalakshmi, Amancherla
collection PubMed
description One of the important prerequisites for a successful orthopedic implant apart from being osteoconductive is the elicitation of a favorable immune response that does not lead to the rejection of the implant by the host tissue. Anodization is one of the simplest surface modification processes used to create nanotextured and nanotubular features on metal oxides which has been shown to improve bone formation. Anodization of titanium (Ti) leads to the formation of TiO(2) nanotubes on the surface, and the presence of these nanotubes mimics the natural nanoscale features of bone, which in turn contributes to improved bone cell attachment, migration, and proliferation. However, inflammatory cell responses on anodized Ti remains to be tested. It is hypothesized that surface roughness and surface feature size on anodized Ti can be carefully manipulated to control immune cell (specifically, macrophages) responses. Here, when Ti samples were anodized at 10 V in the presence of 1% hydrofluoric acid (HF) for 1 minute, nanotextured (nonnanotube) surfaces were created. When anodization of Ti samples was carried out with 1% HF for 10 minutes at 15 V, nanotubes with 40–50 nm diameters were formed, whereas at 20 V with 1% HF for 10 minutes, nanotubes with 60–70 nm diameters were formed. In this study, a reduced density of macrophages was observed after 24 hours of culture on nanotextured and nanotubular Ti samples which were anodized at 10, 15, and 20 V, compared with conventional unmodified Ti samples. This in vitro study thus demonstrated a reduced density of macrophages on anodized Ti, thereby providing further evidence of the greater efficacy of anodized Ti for orthopedic applications.
format Online
Article
Text
id pubmed-3184936
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-31849362011-10-06 Reduced adhesion of macrophages on anodized titanium with select nanotube surface features Rajyalakshmi, Amancherla Ercan, Batur Balasubramanian, K Webster, Thomas J Int J Nanomedicine Original Research One of the important prerequisites for a successful orthopedic implant apart from being osteoconductive is the elicitation of a favorable immune response that does not lead to the rejection of the implant by the host tissue. Anodization is one of the simplest surface modification processes used to create nanotextured and nanotubular features on metal oxides which has been shown to improve bone formation. Anodization of titanium (Ti) leads to the formation of TiO(2) nanotubes on the surface, and the presence of these nanotubes mimics the natural nanoscale features of bone, which in turn contributes to improved bone cell attachment, migration, and proliferation. However, inflammatory cell responses on anodized Ti remains to be tested. It is hypothesized that surface roughness and surface feature size on anodized Ti can be carefully manipulated to control immune cell (specifically, macrophages) responses. Here, when Ti samples were anodized at 10 V in the presence of 1% hydrofluoric acid (HF) for 1 minute, nanotextured (nonnanotube) surfaces were created. When anodization of Ti samples was carried out with 1% HF for 10 minutes at 15 V, nanotubes with 40–50 nm diameters were formed, whereas at 20 V with 1% HF for 10 minutes, nanotubes with 60–70 nm diameters were formed. In this study, a reduced density of macrophages was observed after 24 hours of culture on nanotextured and nanotubular Ti samples which were anodized at 10, 15, and 20 V, compared with conventional unmodified Ti samples. This in vitro study thus demonstrated a reduced density of macrophages on anodized Ti, thereby providing further evidence of the greater efficacy of anodized Ti for orthopedic applications. Dove Medical Press 2011 2011-08-23 /pmc/articles/PMC3184936/ /pubmed/21980239 http://dx.doi.org/10.2147/IJN.S22763 Text en © 2011 Rajyalakshmi et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Rajyalakshmi, Amancherla
Ercan, Batur
Balasubramanian, K
Webster, Thomas J
Reduced adhesion of macrophages on anodized titanium with select nanotube surface features
title Reduced adhesion of macrophages on anodized titanium with select nanotube surface features
title_full Reduced adhesion of macrophages on anodized titanium with select nanotube surface features
title_fullStr Reduced adhesion of macrophages on anodized titanium with select nanotube surface features
title_full_unstemmed Reduced adhesion of macrophages on anodized titanium with select nanotube surface features
title_short Reduced adhesion of macrophages on anodized titanium with select nanotube surface features
title_sort reduced adhesion of macrophages on anodized titanium with select nanotube surface features
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3184936/
https://www.ncbi.nlm.nih.gov/pubmed/21980239
http://dx.doi.org/10.2147/IJN.S22763
work_keys_str_mv AT rajyalakshmiamancherla reducedadhesionofmacrophagesonanodizedtitaniumwithselectnanotubesurfacefeatures
AT ercanbatur reducedadhesionofmacrophagesonanodizedtitaniumwithselectnanotubesurfacefeatures
AT balasubramaniank reducedadhesionofmacrophagesonanodizedtitaniumwithselectnanotubesurfacefeatures
AT websterthomasj reducedadhesionofmacrophagesonanodizedtitaniumwithselectnanotubesurfacefeatures