High Cecal Intubation Rates With a New Computer-Assisted Colonoscope: A Feasibility Study

OBJECTIVES: The acceptability of colonoscopy as a screening test is limited by several factors including patient discomfort. A new self-propelled colonoscope, the Invendo SC20 (Invendo Medical GmbH), may be helpful in reducing sedation. It consists of a sheathed endoscope contained within an “invert...

Descripción completa

Detalles Bibliográficos
Autores principales: Groth, Stefan, Rex, Douglas K, Rösch, Thomas, Hoepffner, Nicolas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3185926/
https://www.ncbi.nlm.nih.gov/pubmed/21386833
http://dx.doi.org/10.1038/ajg.2011.52
_version_ 1782213277019799552
author Groth, Stefan
Rex, Douglas K
Rösch, Thomas
Hoepffner, Nicolas
author_facet Groth, Stefan
Rex, Douglas K
Rösch, Thomas
Hoepffner, Nicolas
author_sort Groth, Stefan
collection PubMed
description OBJECTIVES: The acceptability of colonoscopy as a screening test is limited by several factors including patient discomfort. A new self-propelled colonoscope, the Invendo SC20 (Invendo Medical GmbH), may be helpful in reducing sedation. It consists of a sheathed endoscope contained within an “inverted sleeve,” and having an instrument channel and an electrohydraulic bendable tip; it is steered using a handheld device and propelled by a motorized drive unit. This study assessed the safety and efficacy of this new endoscope in volunteers undergoing colorectal cancer (CRC) screening. METHODS: Paid healthy volunteers aged 50–70 years and eligible for screening colonoscopy were included. Total colonoscopy using carbon dioxide insufflation or water instillation on demand was attempted, with all procedures being started without sedation. The main outcome parameters were safety and the cecal intubation rate. RESULTS: A total of 61 volunteers participated (34 men and 27 women; mean age 57.5 years). The cecum was reached in 60 volunteers (cecal intubation rate of 98.4%). The median time to reach the cecum was 15 min (range 7–53.5). Sedation was given in three individuals (4.9%). On withdrawal (median time 15 min), the material for histological evaluation was obtained from 33 polyps (mean size 4.8 mm) in 23 people by biopsy forceps or snare. No device-related complications were encountered. CONCLUSIONS: A new computer-assisted colonoscope, controlled using a handheld device, showed excellent cecal intubation rates during screening examinations, with sedation required in only ∼5% of screenees. Further clinical and comparative studies are warranted.
format Online
Article
Text
id pubmed-3185926
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-31859262011-10-18 High Cecal Intubation Rates With a New Computer-Assisted Colonoscope: A Feasibility Study Groth, Stefan Rex, Douglas K Rösch, Thomas Hoepffner, Nicolas Am J Gastroenterol Endoscopy OBJECTIVES: The acceptability of colonoscopy as a screening test is limited by several factors including patient discomfort. A new self-propelled colonoscope, the Invendo SC20 (Invendo Medical GmbH), may be helpful in reducing sedation. It consists of a sheathed endoscope contained within an “inverted sleeve,” and having an instrument channel and an electrohydraulic bendable tip; it is steered using a handheld device and propelled by a motorized drive unit. This study assessed the safety and efficacy of this new endoscope in volunteers undergoing colorectal cancer (CRC) screening. METHODS: Paid healthy volunteers aged 50–70 years and eligible for screening colonoscopy were included. Total colonoscopy using carbon dioxide insufflation or water instillation on demand was attempted, with all procedures being started without sedation. The main outcome parameters were safety and the cecal intubation rate. RESULTS: A total of 61 volunteers participated (34 men and 27 women; mean age 57.5 years). The cecum was reached in 60 volunteers (cecal intubation rate of 98.4%). The median time to reach the cecum was 15 min (range 7–53.5). Sedation was given in three individuals (4.9%). On withdrawal (median time 15 min), the material for histological evaluation was obtained from 33 polyps (mean size 4.8 mm) in 23 people by biopsy forceps or snare. No device-related complications were encountered. CONCLUSIONS: A new computer-assisted colonoscope, controlled using a handheld device, showed excellent cecal intubation rates during screening examinations, with sedation required in only ∼5% of screenees. Further clinical and comparative studies are warranted. Nature Publishing Group 2011-06 2011-03-08 /pmc/articles/PMC3185926/ /pubmed/21386833 http://dx.doi.org/10.1038/ajg.2011.52 Text en Copyright © 2011 American College of Gastroenterology http://creativecommons.org/licenses/by-nc-nd/3.0/ This work is licensed under the Creative Commons Attribution-NonCommercial-No Derivative Works 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Endoscopy
Groth, Stefan
Rex, Douglas K
Rösch, Thomas
Hoepffner, Nicolas
High Cecal Intubation Rates With a New Computer-Assisted Colonoscope: A Feasibility Study
title High Cecal Intubation Rates With a New Computer-Assisted Colonoscope: A Feasibility Study
title_full High Cecal Intubation Rates With a New Computer-Assisted Colonoscope: A Feasibility Study
title_fullStr High Cecal Intubation Rates With a New Computer-Assisted Colonoscope: A Feasibility Study
title_full_unstemmed High Cecal Intubation Rates With a New Computer-Assisted Colonoscope: A Feasibility Study
title_short High Cecal Intubation Rates With a New Computer-Assisted Colonoscope: A Feasibility Study
title_sort high cecal intubation rates with a new computer-assisted colonoscope: a feasibility study
topic Endoscopy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3185926/
https://www.ncbi.nlm.nih.gov/pubmed/21386833
http://dx.doi.org/10.1038/ajg.2011.52
work_keys_str_mv AT grothstefan highcecalintubationrateswithanewcomputerassistedcolonoscopeafeasibilitystudy
AT rexdouglask highcecalintubationrateswithanewcomputerassistedcolonoscopeafeasibilitystudy
AT roschthomas highcecalintubationrateswithanewcomputerassistedcolonoscopeafeasibilitystudy
AT hoepffnernicolas highcecalintubationrateswithanewcomputerassistedcolonoscopeafeasibilitystudy