A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

PURPOSE: This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. MATERIALS AND METHODS: A commercia...

Descripción completa

Detalles Bibliográficos
Autores principales: Ana, Faria-Inocencio, Mercedes, Gallas-Torreira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3189535/
https://www.ncbi.nlm.nih.gov/pubmed/22010068
http://dx.doi.org/10.5624/isd.2011.41.3.115
_version_ 1782213475327541248
author Ana, Faria-Inocencio
Mercedes, Gallas-Torreira
author_facet Ana, Faria-Inocencio
Mercedes, Gallas-Torreira
author_sort Ana, Faria-Inocencio
collection PubMed
description PURPOSE: This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. MATERIALS AND METHODS: A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. RESULTS: This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. CONCLUSION: This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.
format Online
Article
Text
id pubmed-3189535
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-31895352011-10-18 A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery Ana, Faria-Inocencio Mercedes, Gallas-Torreira Imaging Sci Dent Technical Report PURPOSE: This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. MATERIALS AND METHODS: A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. RESULTS: This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. CONCLUSION: This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin. Korean Academy of Oral and Maxillofacial Radiology 2011-09 2011-09-15 /pmc/articles/PMC3189535/ /pubmed/22010068 http://dx.doi.org/10.5624/isd.2011.41.3.115 Text en Copyright © 2011 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Report
Ana, Faria-Inocencio
Mercedes, Gallas-Torreira
A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery
title A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery
title_full A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery
title_fullStr A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery
title_full_unstemmed A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery
title_short A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery
title_sort modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery
topic Technical Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3189535/
https://www.ncbi.nlm.nih.gov/pubmed/22010068
http://dx.doi.org/10.5624/isd.2011.41.3.115
work_keys_str_mv AT anafariainocencio amodifieddeviceforintraoralradiographytoassessthedistalosseousdefectsofmandibularsecondmolarafterimpactedthirdmolarsurgery
AT mercedesgallastorreira amodifieddeviceforintraoralradiographytoassessthedistalosseousdefectsofmandibularsecondmolarafterimpactedthirdmolarsurgery
AT anafariainocencio modifieddeviceforintraoralradiographytoassessthedistalosseousdefectsofmandibularsecondmolarafterimpactedthirdmolarsurgery
AT mercedesgallastorreira modifieddeviceforintraoralradiographytoassessthedistalosseousdefectsofmandibularsecondmolarafterimpactedthirdmolarsurgery