Cargando…

Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program

Study Objective. Prospectively compare outcomes of robotically assisted and laparoscopic hysterectomy in the process of implementing a new robotic program. Design. Prospectively comparative observational nonrandomized study. Design Classification. II-1. Setting. Tertiary caregiver university hospita...

Descripción completa

Detalles Bibliográficos
Autores principales: Kilic, Gokhan Sami, Moore, Gradie, Elbatanony, Ayman, Radecki, Carmen, Phelps, John Y., Borahay, Mostafa A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3189617/
https://www.ncbi.nlm.nih.gov/pubmed/22007229
http://dx.doi.org/10.1155/2011/683703
_version_ 1782213491536429056
author Kilic, Gokhan Sami
Moore, Gradie
Elbatanony, Ayman
Radecki, Carmen
Phelps, John Y.
Borahay, Mostafa A.
author_facet Kilic, Gokhan Sami
Moore, Gradie
Elbatanony, Ayman
Radecki, Carmen
Phelps, John Y.
Borahay, Mostafa A.
author_sort Kilic, Gokhan Sami
collection PubMed
description Study Objective. Prospectively compare outcomes of robotically assisted and laparoscopic hysterectomy in the process of implementing a new robotic program. Design. Prospectively comparative observational nonrandomized study. Design Classification. II-1. Setting. Tertiary caregiver university hospital. Patients. Data collected consecutively 24 months, 34 patients underwent laparoscopic hysterectomy, 25 patients underwent robotic hysterectomy, and 11 patients underwent vaginal hysterectomy at our institution. Interventions. Outcomes of robotically assisted, laparoscopic, and vaginal complex hysterectomies performed by a single surgeon for noncancerous indications. Measurements and Main Results. Operative times were 208.3 ± 59.01 minutes for laparoscopic, 286.2 ± 82.87 minutes for robotic, and 163.5 ± 61.89 minutes for vaginal (P < .0001). Estimated blood loss for patients undergoing laparoscopic surgery was 242.7 ± 211.37 cc, 137.4 ± 107.50 cc for robotic surgery, and 243.2 ± 127.52 cc for vaginal surgery (P = 0.05). The mean length of stay ranged from 1.8 to 2.3 days for the 3 methods. Association was significant for uterine weight (P = 0.0043) among surgery methods. Conclusion. Robotically assisted hysterectomy is feasible with low morbidity, a shorter hospital stay, and less blood loss. This suggests that robotic assistance facilitates a minimally invasive approach for patients with larger uterine size even during implementing a new robotic program.
format Online
Article
Text
id pubmed-3189617
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-31896172011-10-17 Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program Kilic, Gokhan Sami Moore, Gradie Elbatanony, Ayman Radecki, Carmen Phelps, John Y. Borahay, Mostafa A. Obstet Gynecol Int Clinical Study Study Objective. Prospectively compare outcomes of robotically assisted and laparoscopic hysterectomy in the process of implementing a new robotic program. Design. Prospectively comparative observational nonrandomized study. Design Classification. II-1. Setting. Tertiary caregiver university hospital. Patients. Data collected consecutively 24 months, 34 patients underwent laparoscopic hysterectomy, 25 patients underwent robotic hysterectomy, and 11 patients underwent vaginal hysterectomy at our institution. Interventions. Outcomes of robotically assisted, laparoscopic, and vaginal complex hysterectomies performed by a single surgeon for noncancerous indications. Measurements and Main Results. Operative times were 208.3 ± 59.01 minutes for laparoscopic, 286.2 ± 82.87 minutes for robotic, and 163.5 ± 61.89 minutes for vaginal (P < .0001). Estimated blood loss for patients undergoing laparoscopic surgery was 242.7 ± 211.37 cc, 137.4 ± 107.50 cc for robotic surgery, and 243.2 ± 127.52 cc for vaginal surgery (P = 0.05). The mean length of stay ranged from 1.8 to 2.3 days for the 3 methods. Association was significant for uterine weight (P = 0.0043) among surgery methods. Conclusion. Robotically assisted hysterectomy is feasible with low morbidity, a shorter hospital stay, and less blood loss. This suggests that robotic assistance facilitates a minimally invasive approach for patients with larger uterine size even during implementing a new robotic program. Hindawi Publishing Corporation 2011 2011-10-05 /pmc/articles/PMC3189617/ /pubmed/22007229 http://dx.doi.org/10.1155/2011/683703 Text en Copyright © 2011 Gokhan Sami Kilic et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Kilic, Gokhan Sami
Moore, Gradie
Elbatanony, Ayman
Radecki, Carmen
Phelps, John Y.
Borahay, Mostafa A.
Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program
title Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program
title_full Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program
title_fullStr Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program
title_full_unstemmed Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program
title_short Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program
title_sort comparison of perioperative outcomes of total laparoscopic and robotically assisted hysterectomy for benign pathology during introduction of a robotic program
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3189617/
https://www.ncbi.nlm.nih.gov/pubmed/22007229
http://dx.doi.org/10.1155/2011/683703
work_keys_str_mv AT kilicgokhansami comparisonofperioperativeoutcomesoftotallaparoscopicandroboticallyassistedhysterectomyforbenignpathologyduringintroductionofaroboticprogram
AT mooregradie comparisonofperioperativeoutcomesoftotallaparoscopicandroboticallyassistedhysterectomyforbenignpathologyduringintroductionofaroboticprogram
AT elbatanonyayman comparisonofperioperativeoutcomesoftotallaparoscopicandroboticallyassistedhysterectomyforbenignpathologyduringintroductionofaroboticprogram
AT radeckicarmen comparisonofperioperativeoutcomesoftotallaparoscopicandroboticallyassistedhysterectomyforbenignpathologyduringintroductionofaroboticprogram
AT phelpsjohny comparisonofperioperativeoutcomesoftotallaparoscopicandroboticallyassistedhysterectomyforbenignpathologyduringintroductionofaroboticprogram
AT borahaymostafaa comparisonofperioperativeoutcomesoftotallaparoscopicandroboticallyassistedhysterectomyforbenignpathologyduringintroductionofaroboticprogram