Cargando…

Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state

Surface replacement arthroplasty for proximal interphalangeal joint and metacarpophalangeal joints are becoming popular. Low profile, anatomically designed implants limit the amount of bone removed but need preservation of the collateral ligaments. Pyrocarbon and cobalt-chrome stemmed unconstrained...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Harvinder, Dias, Joseph J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publication 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3193644/
https://www.ncbi.nlm.nih.gov/pubmed/22022042
http://dx.doi.org/10.4103/0970-0358.85353
_version_ 1782213854434951168
author Singh, Harvinder
Dias, Joseph J.
author_facet Singh, Harvinder
Dias, Joseph J.
author_sort Singh, Harvinder
collection PubMed
description Surface replacement arthroplasty for proximal interphalangeal joint and metacarpophalangeal joints are becoming popular. Low profile, anatomically designed implants limit the amount of bone removed but need preservation of the collateral ligaments. Pyrocarbon and cobalt-chrome stemmed unconstrained implants on ultra-high molecular weight polyethylene are the two commonly available bearing surfaces. The indications for small joint arthroplasty are degenerative, post-traumatic or rheumatoid arthritis. Early results are encouraging, primarily in patient satisfaction and pain relief, but are based on low numbers. The main concerns are progressive loss of range due to implant settling, dislocation, squeaking and poor osteo-integration with the appearance of a radiolucent line at the bone–implant interface. Our experience suggests that metacarpophalangeal joint replacements consistently give good results.
format Online
Article
Text
id pubmed-3193644
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publication
record_format MEDLINE/PubMed
spelling pubmed-31936442011-10-21 Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state Singh, Harvinder Dias, Joseph J. Indian J Plast Surg Review Article Surface replacement arthroplasty for proximal interphalangeal joint and metacarpophalangeal joints are becoming popular. Low profile, anatomically designed implants limit the amount of bone removed but need preservation of the collateral ligaments. Pyrocarbon and cobalt-chrome stemmed unconstrained implants on ultra-high molecular weight polyethylene are the two commonly available bearing surfaces. The indications for small joint arthroplasty are degenerative, post-traumatic or rheumatoid arthritis. Early results are encouraging, primarily in patient satisfaction and pain relief, but are based on low numbers. The main concerns are progressive loss of range due to implant settling, dislocation, squeaking and poor osteo-integration with the appearance of a radiolucent line at the bone–implant interface. Our experience suggests that metacarpophalangeal joint replacements consistently give good results. Medknow Publication 2011 /pmc/articles/PMC3193644/ /pubmed/22022042 http://dx.doi.org/10.4103/0970-0358.85353 Text en Copyright: © Indian Journal of Plastic Surgery http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Singh, Harvinder
Dias, Joseph J.
Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state
title Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state
title_full Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state
title_fullStr Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state
title_full_unstemmed Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state
title_short Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state
title_sort surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: the current state
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3193644/
https://www.ncbi.nlm.nih.gov/pubmed/22022042
http://dx.doi.org/10.4103/0970-0358.85353
work_keys_str_mv AT singhharvinder surfacereplacementarthroplastyoftheproximalinterphalangealandmetacarpophalangealjointsthecurrentstate
AT diasjosephj surfacereplacementarthroplastyoftheproximalinterphalangealandmetacarpophalangealjointsthecurrentstate