Cargando…

Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes

This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance char...

Descripción completa

Detalles Bibliográficos
Autores principales: Frag, Eman Y. Z., Mohamed, Gehad G., Khalil, Mohamed M., Hwehy, Mohammad M. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3195277/
https://www.ncbi.nlm.nih.gov/pubmed/22013443
http://dx.doi.org/10.1155/2011/604741
_version_ 1782214106103676928
author Frag, Eman Y. Z.
Mohamed, Gehad G.
Khalil, Mohamed M.
Hwehy, Mohammad M. A.
author_facet Frag, Eman Y. Z.
Mohamed, Gehad G.
Khalil, Mohamed M.
Hwehy, Mohammad M. A.
author_sort Frag, Eman Y. Z.
collection PubMed
description This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fast, stable, and linear response for KTF over the concentration range of 10(−7) to 10(−2) mol L(−1). The electrodes show Nernstian slope value of 52.51 ± 0.20 and 51.51 ± 0.25 mV decade(−1) for CPE and PVC membrane electrodes at 30°C, respectively. The potential is nearly stable over the pH range 3.0–6.0 and 2.0–7.0 for CPE and PVC membrane electrodes, respectively. Selectivity coefficient values towards different inorganic cations, sugars, and amino acids reflect high selectivity of the prepared electrodes. The electrodes responses at different temperatures were also studied, and long operational lifetime of 12 and 5 weeks for CPE and PVC membrane electrodes, respectively, were found. These are used for determination of ketotifen fumarate using potentiometric titration, calibration, and standard addition methods in pure samples, its pharmaceutical preparations (Zaditen tablets), and biological fluid (urine). The direct potentiometric determination of KTF using the proposed sensors gave recoveries % of 98.97 ± 0.53 and 98.62 ± 0.74 with RSD 1.42 and 0.63% for CPE and PVC membrane selective electrodes, respectively. Validation of the method shows suitability of the proposed sensors for use in quality control assessment of KTF. The obtained results were in a good agreement with those obtained using the reported spectrophotometric method.
format Online
Article
Text
id pubmed-3195277
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-31952772011-10-19 Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes Frag, Eman Y. Z. Mohamed, Gehad G. Khalil, Mohamed M. Hwehy, Mohammad M. A. Int J Anal Chem Research Article This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fast, stable, and linear response for KTF over the concentration range of 10(−7) to 10(−2) mol L(−1). The electrodes show Nernstian slope value of 52.51 ± 0.20 and 51.51 ± 0.25 mV decade(−1) for CPE and PVC membrane electrodes at 30°C, respectively. The potential is nearly stable over the pH range 3.0–6.0 and 2.0–7.0 for CPE and PVC membrane electrodes, respectively. Selectivity coefficient values towards different inorganic cations, sugars, and amino acids reflect high selectivity of the prepared electrodes. The electrodes responses at different temperatures were also studied, and long operational lifetime of 12 and 5 weeks for CPE and PVC membrane electrodes, respectively, were found. These are used for determination of ketotifen fumarate using potentiometric titration, calibration, and standard addition methods in pure samples, its pharmaceutical preparations (Zaditen tablets), and biological fluid (urine). The direct potentiometric determination of KTF using the proposed sensors gave recoveries % of 98.97 ± 0.53 and 98.62 ± 0.74 with RSD 1.42 and 0.63% for CPE and PVC membrane selective electrodes, respectively. Validation of the method shows suitability of the proposed sensors for use in quality control assessment of KTF. The obtained results were in a good agreement with those obtained using the reported spectrophotometric method. Hindawi Publishing Corporation 2011 2011-10-13 /pmc/articles/PMC3195277/ /pubmed/22013443 http://dx.doi.org/10.1155/2011/604741 Text en Copyright © 2011 Eman Y. Z. Frag et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Frag, Eman Y. Z.
Mohamed, Gehad G.
Khalil, Mohamed M.
Hwehy, Mohammad M. A.
Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes
title Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes
title_full Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes
title_fullStr Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes
title_full_unstemmed Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes
title_short Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes
title_sort potentiometric determination of ketotifen fumarate in pharmaceutical preparations and urine using carbon paste and pvc membrane selective electrodes
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3195277/
https://www.ncbi.nlm.nih.gov/pubmed/22013443
http://dx.doi.org/10.1155/2011/604741
work_keys_str_mv AT fragemanyz potentiometricdeterminationofketotifenfumarateinpharmaceuticalpreparationsandurineusingcarbonpasteandpvcmembraneselectiveelectrodes
AT mohamedgehadg potentiometricdeterminationofketotifenfumarateinpharmaceuticalpreparationsandurineusingcarbonpasteandpvcmembraneselectiveelectrodes
AT khalilmohamedm potentiometricdeterminationofketotifenfumarateinpharmaceuticalpreparationsandurineusingcarbonpasteandpvcmembraneselectiveelectrodes
AT hwehymohammadma potentiometricdeterminationofketotifenfumarateinpharmaceuticalpreparationsandurineusingcarbonpasteandpvcmembraneselectiveelectrodes