Cargando…
An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy
Urethral NTCP has been determined for three prostates implanted with seeds based on (125)I (145 Gy), (103)Pd (125 Gy), (131)Cs (115 Gy), (103)Pd-(125)I (145 Gy), or (103)Pd-(131)Cs (115 Gy or 130 Gy). First, DU(20), meaning that 20% of the urhral volume receive a dose of at least DU(20), is converte...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3195343/ https://www.ncbi.nlm.nih.gov/pubmed/22096647 http://dx.doi.org/10.1155/2011/128360 |
_version_ | 1782214118448562176 |
---|---|
author | Nuttens, V. E. Nahum, A. E. Lucas, S. |
author_facet | Nuttens, V. E. Nahum, A. E. Lucas, S. |
author_sort | Nuttens, V. E. |
collection | PubMed |
description | Urethral NTCP has been determined for three prostates implanted with seeds based on (125)I (145 Gy), (103)Pd (125 Gy), (131)Cs (115 Gy), (103)Pd-(125)I (145 Gy), or (103)Pd-(131)Cs (115 Gy or 130 Gy). First, DU(20), meaning that 20% of the urhral volume receive a dose of at least DU(20), is converted into an I-125 LDR equivalent DU(20) in order to use the urethral NTCP model. Second, the propagation of uncertainties through the steps in the NTCP calculation was assessed in order to identify the parameters responsible for large data uncertainties. Two sets of radiobiological parameters were studied. The NTCP results all fall in the 19%–23% range and are associated with large uncertainties, making the comparison difficult. Depending on the dataset chosen, the ranking of NTCP values among the six seed implants studied changes. Moreover, the large uncertainties on the fitting parameters of the urethral NTCP model result in large uncertainty on the NTCP value. In conclusion, the use of NTCP model for permanent brachytherapy is feasible but it is essential that the uncertainties on the parameters in the model be reduced. |
format | Online Article Text |
id | pubmed-3195343 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-31953432011-11-17 An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy Nuttens, V. E. Nahum, A. E. Lucas, S. Prostate Cancer Research Article Urethral NTCP has been determined for three prostates implanted with seeds based on (125)I (145 Gy), (103)Pd (125 Gy), (131)Cs (115 Gy), (103)Pd-(125)I (145 Gy), or (103)Pd-(131)Cs (115 Gy or 130 Gy). First, DU(20), meaning that 20% of the urhral volume receive a dose of at least DU(20), is converted into an I-125 LDR equivalent DU(20) in order to use the urethral NTCP model. Second, the propagation of uncertainties through the steps in the NTCP calculation was assessed in order to identify the parameters responsible for large data uncertainties. Two sets of radiobiological parameters were studied. The NTCP results all fall in the 19%–23% range and are associated with large uncertainties, making the comparison difficult. Depending on the dataset chosen, the ranking of NTCP values among the six seed implants studied changes. Moreover, the large uncertainties on the fitting parameters of the urethral NTCP model result in large uncertainty on the NTCP value. In conclusion, the use of NTCP model for permanent brachytherapy is feasible but it is essential that the uncertainties on the parameters in the model be reduced. Hindawi Publishing Corporation 2011 2011-07-06 /pmc/articles/PMC3195343/ /pubmed/22096647 http://dx.doi.org/10.1155/2011/128360 Text en Copyright © 2011 V. E. Nuttens et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Nuttens, V. E. Nahum, A. E. Lucas, S. An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy |
title | An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy |
title_full | An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy |
title_fullStr | An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy |
title_full_unstemmed | An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy |
title_short | An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy |
title_sort | ntcp analysis of urethral complications from low doserate mono- and bi-radionuclide brachytherapy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3195343/ https://www.ncbi.nlm.nih.gov/pubmed/22096647 http://dx.doi.org/10.1155/2011/128360 |
work_keys_str_mv | AT nuttensve anntcpanalysisofurethralcomplicationsfromlowdoseratemonoandbiradionuclidebrachytherapy AT nahumae anntcpanalysisofurethralcomplicationsfromlowdoseratemonoandbiradionuclidebrachytherapy AT lucass anntcpanalysisofurethralcomplicationsfromlowdoseratemonoandbiradionuclidebrachytherapy AT nuttensve ntcpanalysisofurethralcomplicationsfromlowdoseratemonoandbiradionuclidebrachytherapy AT nahumae ntcpanalysisofurethralcomplicationsfromlowdoseratemonoandbiradionuclidebrachytherapy AT lucass ntcpanalysisofurethralcomplicationsfromlowdoseratemonoandbiradionuclidebrachytherapy |