Cargando…

Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing

BACKGROUND: Recent studies using sheep critical sized defect models to test tissue engineered products report high morbidity and complications rates. This study evaluates a large bone defect model in the sheep tibia, stabilized with two, a novel Carbon fibre Poly-ether-ether-ketone (CF-PEEK) and a l...

Descripción completa

Detalles Bibliográficos
Autores principales: Hahn, Joachim A, Witte, Tanja S, Arens, Daniel, Pearce, Alexandra, Pearce, Simon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3195802/
https://www.ncbi.nlm.nih.gov/pubmed/21958221
http://dx.doi.org/10.1186/1471-2474-12-214
_version_ 1782214165615607808
author Hahn, Joachim A
Witte, Tanja S
Arens, Daniel
Pearce, Alexandra
Pearce, Simon
author_facet Hahn, Joachim A
Witte, Tanja S
Arens, Daniel
Pearce, Alexandra
Pearce, Simon
author_sort Hahn, Joachim A
collection PubMed
description BACKGROUND: Recent studies using sheep critical sized defect models to test tissue engineered products report high morbidity and complications rates. This study evaluates a large bone defect model in the sheep tibia, stabilized with two, a novel Carbon fibre Poly-ether-ether-ketone (CF-PEEK) and a locking compression plate (LCP) which could sustain duration for up to 6 month with an acceptable low complication rate. METHODS: A large bone defect of 3 cm was performed in the mid diaphysis of the right tibia in 33 sheep. The defect was stabilised with the CF - PEEK plate and an LCP. All sheep were supported with slings for 8 weeks after surgery. The study was carried out for 3 months in 6 and for 6 months in 27 animals. RESULTS: The surgical procedure could easily be performed in all sheep and continuous in vivo radiographic evaluation of the defect was possible. This long bone critical sized defect model shows with 6.1% a low rate of complications compared with numbers mentioned in the literature. CONCLUSIONS: This experimental animal model could serve as a standard model in comparative research. A well defined standard model would reduce the number of experimental animals needed in future studies and would therefore add to ethical considerations.
format Online
Article
Text
id pubmed-3195802
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-31958022011-10-19 Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing Hahn, Joachim A Witte, Tanja S Arens, Daniel Pearce, Alexandra Pearce, Simon BMC Musculoskelet Disord Technical Advance BACKGROUND: Recent studies using sheep critical sized defect models to test tissue engineered products report high morbidity and complications rates. This study evaluates a large bone defect model in the sheep tibia, stabilized with two, a novel Carbon fibre Poly-ether-ether-ketone (CF-PEEK) and a locking compression plate (LCP) which could sustain duration for up to 6 month with an acceptable low complication rate. METHODS: A large bone defect of 3 cm was performed in the mid diaphysis of the right tibia in 33 sheep. The defect was stabilised with the CF - PEEK plate and an LCP. All sheep were supported with slings for 8 weeks after surgery. The study was carried out for 3 months in 6 and for 6 months in 27 animals. RESULTS: The surgical procedure could easily be performed in all sheep and continuous in vivo radiographic evaluation of the defect was possible. This long bone critical sized defect model shows with 6.1% a low rate of complications compared with numbers mentioned in the literature. CONCLUSIONS: This experimental animal model could serve as a standard model in comparative research. A well defined standard model would reduce the number of experimental animals needed in future studies and would therefore add to ethical considerations. BioMed Central 2011-09-29 /pmc/articles/PMC3195802/ /pubmed/21958221 http://dx.doi.org/10.1186/1471-2474-12-214 Text en Copyright ©2011 Hahn et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Advance
Hahn, Joachim A
Witte, Tanja S
Arens, Daniel
Pearce, Alexandra
Pearce, Simon
Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing
title Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing
title_full Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing
title_fullStr Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing
title_full_unstemmed Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing
title_short Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing
title_sort double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3195802/
https://www.ncbi.nlm.nih.gov/pubmed/21958221
http://dx.doi.org/10.1186/1471-2474-12-214
work_keys_str_mv AT hahnjoachima doubleplatingofovinecriticalsizeddefectsofthetibiaalowmorbiditymodelenablingcontinuousinvivomonitoringofbonehealing
AT wittetanjas doubleplatingofovinecriticalsizeddefectsofthetibiaalowmorbiditymodelenablingcontinuousinvivomonitoringofbonehealing
AT arensdaniel doubleplatingofovinecriticalsizeddefectsofthetibiaalowmorbiditymodelenablingcontinuousinvivomonitoringofbonehealing
AT pearcealexandra doubleplatingofovinecriticalsizeddefectsofthetibiaalowmorbiditymodelenablingcontinuousinvivomonitoringofbonehealing
AT pearcesimon doubleplatingofovinecriticalsizeddefectsofthetibiaalowmorbiditymodelenablingcontinuousinvivomonitoringofbonehealing