Cargando…
Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery
Purpose. Little attention has been given to syringe design and local anaesthetic administration methods. A microprocessor-controlled anaesthetic delivery device has become available that may minimize discomfort during injection. The purpose of this study was to document the pain experience associate...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3197004/ https://www.ncbi.nlm.nih.gov/pubmed/22110923 http://dx.doi.org/10.1155/2011/362396 |
_version_ | 1782214263346036736 |
---|---|
author | Nimigan, André S. Gan, Bing Siang |
author_facet | Nimigan, André S. Gan, Bing Siang |
author_sort | Nimigan, André S. |
collection | PubMed |
description | Purpose. Little attention has been given to syringe design and local anaesthetic administration methods. A microprocessor-controlled anaesthetic delivery device has become available that may minimize discomfort during injection. The purpose of this study was to document the pain experience associated with the use of this system and to compare it with use of a conventional syringe. Methods. A prospective, randomized clinical trial was designed. 40 patients undergoing carpal tunnel release were block randomized according to sex into a two groups: a traditional syringe group and a microprocessor-controlled device group. The primary outcome measure was surgical pain and local anaesthetic administration pain. Secondary outcomes included volume of anaesthetic used and injection time. Results. Analysis showed that equivalent anaesthesia was achieved in the microprocessor-controlled group despite using a significantly lower volume of local anaesthetic (P = .0002). This same group, however, has significantly longer injection times (P < .0001). Pain during the injection process or during surgery was not different between the two groups. Conclusions. This RCT comparing traditional and microprocessor controlled methods of administering local anaesthetic showed similar levels of discomfort in both groups. While the microprocessor-controlled group used less volume, the total time for the administration was significantly greater. |
format | Online Article Text |
id | pubmed-3197004 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-31970042011-11-22 Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery Nimigan, André S. Gan, Bing Siang Pain Res Treat Clinical Study Purpose. Little attention has been given to syringe design and local anaesthetic administration methods. A microprocessor-controlled anaesthetic delivery device has become available that may minimize discomfort during injection. The purpose of this study was to document the pain experience associated with the use of this system and to compare it with use of a conventional syringe. Methods. A prospective, randomized clinical trial was designed. 40 patients undergoing carpal tunnel release were block randomized according to sex into a two groups: a traditional syringe group and a microprocessor-controlled device group. The primary outcome measure was surgical pain and local anaesthetic administration pain. Secondary outcomes included volume of anaesthetic used and injection time. Results. Analysis showed that equivalent anaesthesia was achieved in the microprocessor-controlled group despite using a significantly lower volume of local anaesthetic (P = .0002). This same group, however, has significantly longer injection times (P < .0001). Pain during the injection process or during surgery was not different between the two groups. Conclusions. This RCT comparing traditional and microprocessor controlled methods of administering local anaesthetic showed similar levels of discomfort in both groups. While the microprocessor-controlled group used less volume, the total time for the administration was significantly greater. Hindawi Publishing Corporation 2011 2011-05-25 /pmc/articles/PMC3197004/ /pubmed/22110923 http://dx.doi.org/10.1155/2011/362396 Text en Copyright © 2011 A. S. Nimigan and B. S. Gan. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Nimigan, André S. Gan, Bing Siang Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery |
title | Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery |
title_full | Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery |
title_fullStr | Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery |
title_full_unstemmed | Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery |
title_short | Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery |
title_sort | pain and efficacy rating of a microprocessor-controlled metered injection system for local anaesthesia in minor hand surgery |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3197004/ https://www.ncbi.nlm.nih.gov/pubmed/22110923 http://dx.doi.org/10.1155/2011/362396 |
work_keys_str_mv | AT nimiganandres painandefficacyratingofamicroprocessorcontrolledmeteredinjectionsystemforlocalanaesthesiainminorhandsurgery AT ganbingsiang painandefficacyratingofamicroprocessorcontrolledmeteredinjectionsystemforlocalanaesthesiainminorhandsurgery |