Cargando…
Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
Microfluidic devices have advanced cell studies by providing a dynamic fluidic environment on the scale of the cell for studying, manipulating, sorting and counting cells. However, manipulating the cell within the fluidic domain remains a challenge and requires complicated fabrication protocols for...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MyJove Corporation
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3197411/ https://www.ncbi.nlm.nih.gov/pubmed/21339720 http://dx.doi.org/10.3791/2545 |
_version_ | 1782214303076581376 |
---|---|
author | Millet, Larry J. Park, Kidong Watkins, Nicholas N. Hsia, K. Jimmy Bashir, Rashid |
author_facet | Millet, Larry J. Park, Kidong Watkins, Nicholas N. Hsia, K. Jimmy Bashir, Rashid |
author_sort | Millet, Larry J. |
collection | PubMed |
description | Microfluidic devices have advanced cell studies by providing a dynamic fluidic environment on the scale of the cell for studying, manipulating, sorting and counting cells. However, manipulating the cell within the fluidic domain remains a challenge and requires complicated fabrication protocols for forming valves and electrodes, or demands specialty equipment like optical tweezers. Here, we demonstrate that conventional printed circuit boards (PCB) can be used for the non-contact manipulation of cells by employing dielectrophoresis (DEP) for bead and cell manipulation in laminar flow fields for bioactuation, and for cell and bead separation in multichannel microfluidic devices. First, we present the protocol for assembling the DEP electrodes and microfluidic devices, and preparing the cells for DEP. Then, we characterize the DEP operation with polystyrene beads. Lastly, we show representative results of bead and cell separation in a multichannel microfluidic device. In summary, DEP is an effective method for manipulating particles (beads or cells) within microfluidic devices. |
format | Online Article Text |
id | pubmed-3197411 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | MyJove Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-31974112011-10-26 Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow Millet, Larry J. Park, Kidong Watkins, Nicholas N. Hsia, K. Jimmy Bashir, Rashid J Vis Exp Bioengineering Microfluidic devices have advanced cell studies by providing a dynamic fluidic environment on the scale of the cell for studying, manipulating, sorting and counting cells. However, manipulating the cell within the fluidic domain remains a challenge and requires complicated fabrication protocols for forming valves and electrodes, or demands specialty equipment like optical tweezers. Here, we demonstrate that conventional printed circuit boards (PCB) can be used for the non-contact manipulation of cells by employing dielectrophoresis (DEP) for bead and cell manipulation in laminar flow fields for bioactuation, and for cell and bead separation in multichannel microfluidic devices. First, we present the protocol for assembling the DEP electrodes and microfluidic devices, and preparing the cells for DEP. Then, we characterize the DEP operation with polystyrene beads. Lastly, we show representative results of bead and cell separation in a multichannel microfluidic device. In summary, DEP is an effective method for manipulating particles (beads or cells) within microfluidic devices. MyJove Corporation 2011-02-04 /pmc/articles/PMC3197411/ /pubmed/21339720 http://dx.doi.org/10.3791/2545 Text en Copyright © 2011, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/ |
spellingShingle | Bioengineering Millet, Larry J. Park, Kidong Watkins, Nicholas N. Hsia, K. Jimmy Bashir, Rashid Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow |
title | Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow |
title_full | Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow |
title_fullStr | Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow |
title_full_unstemmed | Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow |
title_short | Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow |
title_sort | separating beads and cells in multi-channel microfluidic devices using dielectrophoresis and laminar flow |
topic | Bioengineering |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3197411/ https://www.ncbi.nlm.nih.gov/pubmed/21339720 http://dx.doi.org/10.3791/2545 |
work_keys_str_mv | AT milletlarryj separatingbeadsandcellsinmultichannelmicrofluidicdevicesusingdielectrophoresisandlaminarflow AT parkkidong separatingbeadsandcellsinmultichannelmicrofluidicdevicesusingdielectrophoresisandlaminarflow AT watkinsnicholasn separatingbeadsandcellsinmultichannelmicrofluidicdevicesusingdielectrophoresisandlaminarflow AT hsiakjimmy separatingbeadsandcellsinmultichannelmicrofluidicdevicesusingdielectrophoresisandlaminarflow AT bashirrashid separatingbeadsandcellsinmultichannelmicrofluidicdevicesusingdielectrophoresisandlaminarflow |