Cargando…

Evaluation of Light-Emitting Diode (LED-660 Nm) Application over Primary Osteoblast-Like Cells on Titanium Surfaces: An In Vitro Study

Background: The goal of this study was to evaluate the behavior of neonatal rat calvarial osteoblast-like cells cultured on different implant surfaces and exposed once or three times to a 660-nm light-emitting diode (LED). Methods: An LED with a 660-nm wavelength was applied once or three times to c...

Descripción completa

Detalles Bibliográficos
Autores principales: Cankaya, Abdulkadir Burak, Erdem, Mehmet Ali, Erdem, Arzu Pınar, Erguven, Mine, Aybar, Buket, Kasapoglu, Cetin, Bilir, Ayhan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3198254/
https://www.ncbi.nlm.nih.gov/pubmed/22022211
_version_ 1782214400219807744
author Cankaya, Abdulkadir Burak
Erdem, Mehmet Ali
Erdem, Arzu Pınar
Erguven, Mine
Aybar, Buket
Kasapoglu, Cetin
Bilir, Ayhan
author_facet Cankaya, Abdulkadir Burak
Erdem, Mehmet Ali
Erdem, Arzu Pınar
Erguven, Mine
Aybar, Buket
Kasapoglu, Cetin
Bilir, Ayhan
author_sort Cankaya, Abdulkadir Burak
collection PubMed
description Background: The goal of this study was to evaluate the behavior of neonatal rat calvarial osteoblast-like cells cultured on different implant surfaces and exposed once or three times to a 660-nm light-emitting diode (LED). Methods: An LED with a 660-nm wavelength was applied once or three times to cultured cells on standard and modified sandblasted acid-etched surfaces (SLA and SLActive; Straumann, Basel, Switzerland). To analyze the effect of the LED on cell proliferation, numbers, and viability, cells were cultured on titanium discs, and measurements were taken after 72 h. Cell proliferation rates were assessed using a bromodeoxyuridine immunohistochemical technique. Cell morphologies were evaluated by scanning electron microscopy (SEM). Results: Osteoblast-like cells proliferated on all tested surfaces, with differences among groups in cell counts and DNA synthesis values. The application of one LED treatment caused a significant increase in cell count in the SLActive group in comparison with the SLA group (p = 0.001), whereas the application of three LED treatments caused a significant decrease in cell count in the SLA group compared with the SLActive group (p < 0.001). After 72 h, the number of cells was highest in the SLActive group exposed once to the LED. Conclusions: One LED application in the SLActive group resulted in significantly increased cell numbers. However, these findings were not exactly compatible with the SEM findings, which demonstrated fewer cells and weak attachments between cells and to the surface. Thus, further studies using different LED application times are needed to clarify the reason for the increased number of cells that are apparently incapable of attaching to the titanium surfaces after 72 h.
format Online
Article
Text
id pubmed-3198254
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-31982542011-10-21 Evaluation of Light-Emitting Diode (LED-660 Nm) Application over Primary Osteoblast-Like Cells on Titanium Surfaces: An In Vitro Study Cankaya, Abdulkadir Burak Erdem, Mehmet Ali Erdem, Arzu Pınar Erguven, Mine Aybar, Buket Kasapoglu, Cetin Bilir, Ayhan Int J Med Sci Research Paper Background: The goal of this study was to evaluate the behavior of neonatal rat calvarial osteoblast-like cells cultured on different implant surfaces and exposed once or three times to a 660-nm light-emitting diode (LED). Methods: An LED with a 660-nm wavelength was applied once or three times to cultured cells on standard and modified sandblasted acid-etched surfaces (SLA and SLActive; Straumann, Basel, Switzerland). To analyze the effect of the LED on cell proliferation, numbers, and viability, cells were cultured on titanium discs, and measurements were taken after 72 h. Cell proliferation rates were assessed using a bromodeoxyuridine immunohistochemical technique. Cell morphologies were evaluated by scanning electron microscopy (SEM). Results: Osteoblast-like cells proliferated on all tested surfaces, with differences among groups in cell counts and DNA synthesis values. The application of one LED treatment caused a significant increase in cell count in the SLActive group in comparison with the SLA group (p = 0.001), whereas the application of three LED treatments caused a significant decrease in cell count in the SLA group compared with the SLActive group (p < 0.001). After 72 h, the number of cells was highest in the SLActive group exposed once to the LED. Conclusions: One LED application in the SLActive group resulted in significantly increased cell numbers. However, these findings were not exactly compatible with the SEM findings, which demonstrated fewer cells and weak attachments between cells and to the surface. Thus, further studies using different LED application times are needed to clarify the reason for the increased number of cells that are apparently incapable of attaching to the titanium surfaces after 72 h. Ivyspring International Publisher 2011-10-04 /pmc/articles/PMC3198254/ /pubmed/22022211 Text en © Ivyspring International Publisher. This is an open-access article distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by-nc-nd/3.0/). Reproduction is permitted for personal, noncommercial use, provided that the article is in whole, unmodified, and properly cited.
spellingShingle Research Paper
Cankaya, Abdulkadir Burak
Erdem, Mehmet Ali
Erdem, Arzu Pınar
Erguven, Mine
Aybar, Buket
Kasapoglu, Cetin
Bilir, Ayhan
Evaluation of Light-Emitting Diode (LED-660 Nm) Application over Primary Osteoblast-Like Cells on Titanium Surfaces: An In Vitro Study
title Evaluation of Light-Emitting Diode (LED-660 Nm) Application over Primary Osteoblast-Like Cells on Titanium Surfaces: An In Vitro Study
title_full Evaluation of Light-Emitting Diode (LED-660 Nm) Application over Primary Osteoblast-Like Cells on Titanium Surfaces: An In Vitro Study
title_fullStr Evaluation of Light-Emitting Diode (LED-660 Nm) Application over Primary Osteoblast-Like Cells on Titanium Surfaces: An In Vitro Study
title_full_unstemmed Evaluation of Light-Emitting Diode (LED-660 Nm) Application over Primary Osteoblast-Like Cells on Titanium Surfaces: An In Vitro Study
title_short Evaluation of Light-Emitting Diode (LED-660 Nm) Application over Primary Osteoblast-Like Cells on Titanium Surfaces: An In Vitro Study
title_sort evaluation of light-emitting diode (led-660 nm) application over primary osteoblast-like cells on titanium surfaces: an in vitro study
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3198254/
https://www.ncbi.nlm.nih.gov/pubmed/22022211
work_keys_str_mv AT cankayaabdulkadirburak evaluationoflightemittingdiodeled660nmapplicationoverprimaryosteoblastlikecellsontitaniumsurfacesaninvitrostudy
AT erdemmehmetali evaluationoflightemittingdiodeled660nmapplicationoverprimaryosteoblastlikecellsontitaniumsurfacesaninvitrostudy
AT erdemarzupınar evaluationoflightemittingdiodeled660nmapplicationoverprimaryosteoblastlikecellsontitaniumsurfacesaninvitrostudy
AT erguvenmine evaluationoflightemittingdiodeled660nmapplicationoverprimaryosteoblastlikecellsontitaniumsurfacesaninvitrostudy
AT aybarbuket evaluationoflightemittingdiodeled660nmapplicationoverprimaryosteoblastlikecellsontitaniumsurfacesaninvitrostudy
AT kasapoglucetin evaluationoflightemittingdiodeled660nmapplicationoverprimaryosteoblastlikecellsontitaniumsurfacesaninvitrostudy
AT bilirayhan evaluationoflightemittingdiodeled660nmapplicationoverprimaryosteoblastlikecellsontitaniumsurfacesaninvitrostudy