Cargando…
Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study
BACKGROUND: Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time p...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3198754/ https://www.ncbi.nlm.nih.gov/pubmed/21974893 http://dx.doi.org/10.1186/1471-2288-11-138 |
_version_ | 1782214486622470144 |
---|---|
author | Engelberger, Rolf P Blazek, Claudia Amsler, Felix Keo, Hong H Baumann, Frédéric Blättler, Werner Baumgartner, Iris Willenberg, Torsten |
author_facet | Engelberger, Rolf P Blazek, Claudia Amsler, Felix Keo, Hong H Baumann, Frédéric Blättler, Werner Baumgartner, Iris Willenberg, Torsten |
author_sort | Engelberger, Rolf P |
collection | PubMed |
description | BACKGROUND: Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. METHODS: Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (leg(BD)) and whole limb (limb(BF)) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CV(A), CV(W)), and as intra-class correlation coefficients (ICC). RESULTS: A total of 492 leg volume measurements were analysed. Both leg(BD )and limb(BF )volumetry were highly reproducible with CV(A )of 0.5% and 0.7%, respectively. Within-individual reproducibility of leg(BD )and limb(BF )volumetry over a three weeks' period was high (CV(W )1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for leg(BD )and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limb(BF )volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CV(W). CONCLUSIONS: Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula. |
format | Online Article Text |
id | pubmed-3198754 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-31987542011-10-24 Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study Engelberger, Rolf P Blazek, Claudia Amsler, Felix Keo, Hong H Baumann, Frédéric Blättler, Werner Baumgartner, Iris Willenberg, Torsten BMC Med Res Methodol Research Article BACKGROUND: Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. METHODS: Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (leg(BD)) and whole limb (limb(BF)) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CV(A), CV(W)), and as intra-class correlation coefficients (ICC). RESULTS: A total of 492 leg volume measurements were analysed. Both leg(BD )and limb(BF )volumetry were highly reproducible with CV(A )of 0.5% and 0.7%, respectively. Within-individual reproducibility of leg(BD )and limb(BF )volumetry over a three weeks' period was high (CV(W )1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for leg(BD )and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limb(BF )volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CV(W). CONCLUSIONS: Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula. BioMed Central 2011-10-05 /pmc/articles/PMC3198754/ /pubmed/21974893 http://dx.doi.org/10.1186/1471-2288-11-138 Text en Copyright ©2011 Engelberger et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Engelberger, Rolf P Blazek, Claudia Amsler, Felix Keo, Hong H Baumann, Frédéric Blättler, Werner Baumgartner, Iris Willenberg, Torsten Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study |
title | Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study |
title_full | Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study |
title_fullStr | Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study |
title_full_unstemmed | Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study |
title_short | Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study |
title_sort | reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3198754/ https://www.ncbi.nlm.nih.gov/pubmed/21974893 http://dx.doi.org/10.1186/1471-2288-11-138 |
work_keys_str_mv | AT engelbergerrolfp reproducibilityanddaytimebiascorrectionofoptoelectroniclegvolumetryaprospectivecohortstudy AT blazekclaudia reproducibilityanddaytimebiascorrectionofoptoelectroniclegvolumetryaprospectivecohortstudy AT amslerfelix reproducibilityanddaytimebiascorrectionofoptoelectroniclegvolumetryaprospectivecohortstudy AT keohongh reproducibilityanddaytimebiascorrectionofoptoelectroniclegvolumetryaprospectivecohortstudy AT baumannfrederic reproducibilityanddaytimebiascorrectionofoptoelectroniclegvolumetryaprospectivecohortstudy AT blattlerwerner reproducibilityanddaytimebiascorrectionofoptoelectroniclegvolumetryaprospectivecohortstudy AT baumgartneriris reproducibilityanddaytimebiascorrectionofoptoelectroniclegvolumetryaprospectivecohortstudy AT willenbergtorsten reproducibilityanddaytimebiascorrectionofoptoelectroniclegvolumetryaprospectivecohortstudy |