Cargando…
Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients
BACKGROUND: The application of advanced 3T MRI imaging techniques to study recovery after subarachnoid hemorrhage (SAH) is complicated by the presence of image artifacts produced by implanted aneurysm clips. To characterize the effect of these artifacts on image quality, we sought to: 1) quantify ex...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3198881/ https://www.ncbi.nlm.nih.gov/pubmed/21970560 http://dx.doi.org/10.1186/1471-2342-11-19 |
_version_ | 1782214500985864192 |
---|---|
author | Khursheed, Faraz Rohlffs, Fiona Suzuki, Shuichi Kim, Dong H Ellmore, Timothy M |
author_facet | Khursheed, Faraz Rohlffs, Fiona Suzuki, Shuichi Kim, Dong H Ellmore, Timothy M |
author_sort | Khursheed, Faraz |
collection | PubMed |
description | BACKGROUND: The application of advanced 3T MRI imaging techniques to study recovery after subarachnoid hemorrhage (SAH) is complicated by the presence of image artifacts produced by implanted aneurysm clips. To characterize the effect of these artifacts on image quality, we sought to: 1) quantify extent of image artifact in SAH patients with implanted aneurysm clips across a range of MR sequences typically used in studies of volumetry, blood oxygen level dependent signal change (BOLD-fMRI), and diffusion-weighted imaging (DW-MRI) and 2) to explore the ability to reconstruct white matter pathways in these patients. METHODS: T1- and T2-weighted structural, BOLD-fMRI, and DW-MRI scans were acquired at 3T in two patients with titanium alloy clips in ACOM and left ACA respectively. Intensity-based planimetric contouring was performed on aligned image volumes to define each artifact. Artifact volumes were quantified by artifact/clip length and artifact/brain volume ratios and analyzed by two-way (scan-by-rater) ANOVAs. Tractography pathways were reconstructed from DW-MRI at varying distances from the artifacts using deterministic methods. RESULTS: Artifact volume varied by MR sequence for length (p = 0.007) and volume (p < 0.001) ratios: it was smallest for structural images, larger for DW-MRI acquisitions, and largest on fMRI images. Inter-rater reliability was high (r = 0.9626, p < 0.0001), and reconstruction of white matter connectivity characteristics increased with distance from the artifact border. In both patients, reconstructed white matter pathways of the uncinate fasciculus and inferior fronto-occipital fasciculus were clearly visible within 2 mm of the artifact border. CONCLUSIONS: Advanced 3T MR can successfully image brain tissue around implanted titanium aneurysm clips at different spatial ranges depending on sequence type. White matter pathways near clip artifacts can be reconstructed and visualized. These findings provide a reference for designing functional and structural neuroimaging studies of recovery in aSAH patients after clip placement. |
format | Online Article Text |
id | pubmed-3198881 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-31988812011-10-23 Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients Khursheed, Faraz Rohlffs, Fiona Suzuki, Shuichi Kim, Dong H Ellmore, Timothy M BMC Med Imaging Research Article BACKGROUND: The application of advanced 3T MRI imaging techniques to study recovery after subarachnoid hemorrhage (SAH) is complicated by the presence of image artifacts produced by implanted aneurysm clips. To characterize the effect of these artifacts on image quality, we sought to: 1) quantify extent of image artifact in SAH patients with implanted aneurysm clips across a range of MR sequences typically used in studies of volumetry, blood oxygen level dependent signal change (BOLD-fMRI), and diffusion-weighted imaging (DW-MRI) and 2) to explore the ability to reconstruct white matter pathways in these patients. METHODS: T1- and T2-weighted structural, BOLD-fMRI, and DW-MRI scans were acquired at 3T in two patients with titanium alloy clips in ACOM and left ACA respectively. Intensity-based planimetric contouring was performed on aligned image volumes to define each artifact. Artifact volumes were quantified by artifact/clip length and artifact/brain volume ratios and analyzed by two-way (scan-by-rater) ANOVAs. Tractography pathways were reconstructed from DW-MRI at varying distances from the artifacts using deterministic methods. RESULTS: Artifact volume varied by MR sequence for length (p = 0.007) and volume (p < 0.001) ratios: it was smallest for structural images, larger for DW-MRI acquisitions, and largest on fMRI images. Inter-rater reliability was high (r = 0.9626, p < 0.0001), and reconstruction of white matter connectivity characteristics increased with distance from the artifact border. In both patients, reconstructed white matter pathways of the uncinate fasciculus and inferior fronto-occipital fasciculus were clearly visible within 2 mm of the artifact border. CONCLUSIONS: Advanced 3T MR can successfully image brain tissue around implanted titanium aneurysm clips at different spatial ranges depending on sequence type. White matter pathways near clip artifacts can be reconstructed and visualized. These findings provide a reference for designing functional and structural neuroimaging studies of recovery in aSAH patients after clip placement. BioMed Central 2011-10-04 /pmc/articles/PMC3198881/ /pubmed/21970560 http://dx.doi.org/10.1186/1471-2342-11-19 Text en Copyright ©2011 Khursheed et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Khursheed, Faraz Rohlffs, Fiona Suzuki, Shuichi Kim, Dong H Ellmore, Timothy M Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients |
title | Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients |
title_full | Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients |
title_fullStr | Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients |
title_full_unstemmed | Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients |
title_short | Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients |
title_sort | artifact quantification and tractography from 3t mri after placement of aneurysm clips in subarachnoid hemorrhage patients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3198881/ https://www.ncbi.nlm.nih.gov/pubmed/21970560 http://dx.doi.org/10.1186/1471-2342-11-19 |
work_keys_str_mv | AT khursheedfaraz artifactquantificationandtractographyfrom3tmriafterplacementofaneurysmclipsinsubarachnoidhemorrhagepatients AT rohlffsfiona artifactquantificationandtractographyfrom3tmriafterplacementofaneurysmclipsinsubarachnoidhemorrhagepatients AT suzukishuichi artifactquantificationandtractographyfrom3tmriafterplacementofaneurysmclipsinsubarachnoidhemorrhagepatients AT kimdongh artifactquantificationandtractographyfrom3tmriafterplacementofaneurysmclipsinsubarachnoidhemorrhagepatients AT ellmoretimothym artifactquantificationandtractographyfrom3tmriafterplacementofaneurysmclipsinsubarachnoidhemorrhagepatients |