Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans

BACKGROUND: The use of different bioactive materials as coating on dental implant to restore tooth function is a growing trend in modern Dentistry. In the present study, hydroxyapatite and the bioactive glass-coated implants were evaluated for their behavior in osseous tissue following implantation...

Descripción completa

Detalles Bibliográficos
Autores principales: Mistry, Surajit, Kundu, Debabrata, Datta, Someswar, Basu, Debabrata, Soundrapandian, Chidambaram
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3200015/
https://www.ncbi.nlm.nih.gov/pubmed/22028507
http://dx.doi.org/10.4103/0972-124X.85663
_version_ 1782214633559425024
author Mistry, Surajit
Kundu, Debabrata
Datta, Someswar
Basu, Debabrata
Soundrapandian, Chidambaram
author_facet Mistry, Surajit
Kundu, Debabrata
Datta, Someswar
Basu, Debabrata
Soundrapandian, Chidambaram
author_sort Mistry, Surajit
collection PubMed
description BACKGROUND: The use of different bioactive materials as coating on dental implant to restore tooth function is a growing trend in modern Dentistry. In the present study, hydroxyapatite and the bioactive glass-coated implants were evaluated for their behavior in osseous tissue following implantation in 14 patients. MATERIALS AND METHODS: Bioactive glass and hydroxyapatite formulated and prepared for coating on Ti-6Al-4V alloy. Hydroxyapatite coating was applied on the implant surface by air plasma spray technique and bioactive glass coating was applied by vitreous enameling technique. Their outcome was assessed after 6 months in vivo study in human. RESULTS: Hydroxyapatite and bioactive glass coating materials were nontoxic and biocompatible. Uneventful healing was observed with both types of implants. CONCLUSION: The results showed bioactive glass is a good alternative coating material for dental implant.
format Online
Article
Text
id pubmed-3200015
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-32000152011-10-25 Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans Mistry, Surajit Kundu, Debabrata Datta, Someswar Basu, Debabrata Soundrapandian, Chidambaram J Indian Soc Periodontol Original Article BACKGROUND: The use of different bioactive materials as coating on dental implant to restore tooth function is a growing trend in modern Dentistry. In the present study, hydroxyapatite and the bioactive glass-coated implants were evaluated for their behavior in osseous tissue following implantation in 14 patients. MATERIALS AND METHODS: Bioactive glass and hydroxyapatite formulated and prepared for coating on Ti-6Al-4V alloy. Hydroxyapatite coating was applied on the implant surface by air plasma spray technique and bioactive glass coating was applied by vitreous enameling technique. Their outcome was assessed after 6 months in vivo study in human. RESULTS: Hydroxyapatite and bioactive glass coating materials were nontoxic and biocompatible. Uneventful healing was observed with both types of implants. CONCLUSION: The results showed bioactive glass is a good alternative coating material for dental implant. Medknow Publications 2011 /pmc/articles/PMC3200015/ /pubmed/22028507 http://dx.doi.org/10.4103/0972-124X.85663 Text en Copyright: © Journal of Indian Society of Periodontology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Mistry, Surajit
Kundu, Debabrata
Datta, Someswar
Basu, Debabrata
Soundrapandian, Chidambaram
Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans
title Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans
title_full Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans
title_fullStr Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans
title_full_unstemmed Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans
title_short Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans
title_sort indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – fabrication and application in humans
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3200015/
https://www.ncbi.nlm.nih.gov/pubmed/22028507
http://dx.doi.org/10.4103/0972-124X.85663
work_keys_str_mv AT mistrysurajit indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans
AT kundudebabrata indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans
AT dattasomeswar indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans
AT basudebabrata indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans
AT soundrapandianchidambaram indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans