Cargando…
Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans
BACKGROUND: The use of different bioactive materials as coating on dental implant to restore tooth function is a growing trend in modern Dentistry. In the present study, hydroxyapatite and the bioactive glass-coated implants were evaluated for their behavior in osseous tissue following implantation...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3200015/ https://www.ncbi.nlm.nih.gov/pubmed/22028507 http://dx.doi.org/10.4103/0972-124X.85663 |
_version_ | 1782214633559425024 |
---|---|
author | Mistry, Surajit Kundu, Debabrata Datta, Someswar Basu, Debabrata Soundrapandian, Chidambaram |
author_facet | Mistry, Surajit Kundu, Debabrata Datta, Someswar Basu, Debabrata Soundrapandian, Chidambaram |
author_sort | Mistry, Surajit |
collection | PubMed |
description | BACKGROUND: The use of different bioactive materials as coating on dental implant to restore tooth function is a growing trend in modern Dentistry. In the present study, hydroxyapatite and the bioactive glass-coated implants were evaluated for their behavior in osseous tissue following implantation in 14 patients. MATERIALS AND METHODS: Bioactive glass and hydroxyapatite formulated and prepared for coating on Ti-6Al-4V alloy. Hydroxyapatite coating was applied on the implant surface by air plasma spray technique and bioactive glass coating was applied by vitreous enameling technique. Their outcome was assessed after 6 months in vivo study in human. RESULTS: Hydroxyapatite and bioactive glass coating materials were nontoxic and biocompatible. Uneventful healing was observed with both types of implants. CONCLUSION: The results showed bioactive glass is a good alternative coating material for dental implant. |
format | Online Article Text |
id | pubmed-3200015 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-32000152011-10-25 Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans Mistry, Surajit Kundu, Debabrata Datta, Someswar Basu, Debabrata Soundrapandian, Chidambaram J Indian Soc Periodontol Original Article BACKGROUND: The use of different bioactive materials as coating on dental implant to restore tooth function is a growing trend in modern Dentistry. In the present study, hydroxyapatite and the bioactive glass-coated implants were evaluated for their behavior in osseous tissue following implantation in 14 patients. MATERIALS AND METHODS: Bioactive glass and hydroxyapatite formulated and prepared for coating on Ti-6Al-4V alloy. Hydroxyapatite coating was applied on the implant surface by air plasma spray technique and bioactive glass coating was applied by vitreous enameling technique. Their outcome was assessed after 6 months in vivo study in human. RESULTS: Hydroxyapatite and bioactive glass coating materials were nontoxic and biocompatible. Uneventful healing was observed with both types of implants. CONCLUSION: The results showed bioactive glass is a good alternative coating material for dental implant. Medknow Publications 2011 /pmc/articles/PMC3200015/ /pubmed/22028507 http://dx.doi.org/10.4103/0972-124X.85663 Text en Copyright: © Journal of Indian Society of Periodontology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Mistry, Surajit Kundu, Debabrata Datta, Someswar Basu, Debabrata Soundrapandian, Chidambaram Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans |
title | Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans |
title_full | Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans |
title_fullStr | Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans |
title_full_unstemmed | Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans |
title_short | Indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – Fabrication and application in humans |
title_sort | indigenous hydroxyapatite coated and bioactive glass coated titanium dental implant system – fabrication and application in humans |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3200015/ https://www.ncbi.nlm.nih.gov/pubmed/22028507 http://dx.doi.org/10.4103/0972-124X.85663 |
work_keys_str_mv | AT mistrysurajit indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans AT kundudebabrata indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans AT dattasomeswar indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans AT basudebabrata indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans AT soundrapandianchidambaram indigenoushydroxyapatitecoatedandbioactiveglasscoatedtitaniumdentalimplantsystemfabricationandapplicationinhumans |