Cargando…

Local recurrences in cervical cancer patients in the setting of image-guided brachytherapy: A comparison of spatial dose distribution within a matched-pair analysis

PURPOSE: It has been shown that a cumulative dose of ⩾87 Gy (EQD2) of external beam radiotherapy (EBRT) and image guided adaptive brachytherapy (IGABT) to the high risk clinical target volume (HR CTV) confer a local control rate >95% in locally advanced cervical cancer. This study examines the do...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmid, Maximilian P., Kirisits, Christian, Nesvacil, Nicole, Dimopoulos, Johannes C.A., Berger, Daniel, Pötter, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Scientific Publishers 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3200439/
https://www.ncbi.nlm.nih.gov/pubmed/21924510
http://dx.doi.org/10.1016/j.radonc.2011.08.014
_version_ 1782214696277901312
author Schmid, Maximilian P.
Kirisits, Christian
Nesvacil, Nicole
Dimopoulos, Johannes C.A.
Berger, Daniel
Pötter, Richard
author_facet Schmid, Maximilian P.
Kirisits, Christian
Nesvacil, Nicole
Dimopoulos, Johannes C.A.
Berger, Daniel
Pötter, Richard
author_sort Schmid, Maximilian P.
collection PubMed
description PURPOSE: It has been shown that a cumulative dose of ⩾87 Gy (EQD2) of external beam radiotherapy (EBRT) and image guided adaptive brachytherapy (IGABT) to the high risk clinical target volume (HR CTV) confer a local control rate >95% in locally advanced cervical cancer. This study examines the dose distribution within the HR CTV and intermediate (IR) CTV in patients with cervical cancer treated with definitive EBRT +/− concomitant chemotherapy and MRI-based IGABT between patients with local recurrence (LR) and patients in continuous complete local remission (CCLR). MATERIAL AND METHODS: From 1998 to 2010, 265 patients were treated with definitive EBRT +/− concomitant chemotherapy and IGABT. Twenty-four LRs were documented. For the statistical analysis all patients with LR were matched to patients in CCLR from our database according to the following criteria: FIGO stage, histology, lymph node status, tumour size and chemotherapy. DVH parameters (D50, D90, D98, D100) were reported for HR CTV and IR CTV. In order to report the minimum dose in the region where the recurrence occurred, the HR CTV/IR CTV were divided into four quadrants on transversal planes. The minimum dose at the HR CTV/IR CTV contour was measured (within the corresponding quadrant closest to the LR) in the treatment planning system. A mean minimum point dose (MPD) was calculated by averaging these measurements on four consecutive slices at the level of the recurrence for each of the 4 brachytherapy fractions. EQD2 doses were calculated by summation of all BT and external beam therapy fractions. For each matched patient in the control group the measurements were performed on the same quadrant and at the same level. RESULTS: Sufficient image data were available for 21 LRs. Eight central failures and 13 non-central failures were observed. The mean D90 and D100 for HR CTV were 77 Gy and 61 Gy for patients with LR and 95 Gy and 71 Gy for patients in CCLR, respectively (p < 0.01). The MPD for HR CTV was 72 Gy for patients in the LR arm and 99 Gy for patients in the CCLR arm (p < 0.01). In the LR arm seven patients had a D90 for HR CTV ⩾87 Gy, however, in only three patients the MPD was ⩾87 Gy. CONCLUSION: This study demonstrated significant differences in local outcome according to the delivered dose. In 85% of the LRs systematic low dose regions with less than 87 Gy were found at HR CTV contour. Systematic low dose regions leading to local recurrence could be detected even if a D90 HR CTV ⩾87 Gy was applied. In addition to DVH parameters, inspection of the spatial dose distribution remains a key point in dose prescription.
format Online
Article
Text
id pubmed-3200439
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Elsevier Scientific Publishers
record_format MEDLINE/PubMed
spelling pubmed-32004392011-10-31 Local recurrences in cervical cancer patients in the setting of image-guided brachytherapy: A comparison of spatial dose distribution within a matched-pair analysis Schmid, Maximilian P. Kirisits, Christian Nesvacil, Nicole Dimopoulos, Johannes C.A. Berger, Daniel Pötter, Richard Radiother Oncol Brachytherapy PURPOSE: It has been shown that a cumulative dose of ⩾87 Gy (EQD2) of external beam radiotherapy (EBRT) and image guided adaptive brachytherapy (IGABT) to the high risk clinical target volume (HR CTV) confer a local control rate >95% in locally advanced cervical cancer. This study examines the dose distribution within the HR CTV and intermediate (IR) CTV in patients with cervical cancer treated with definitive EBRT +/− concomitant chemotherapy and MRI-based IGABT between patients with local recurrence (LR) and patients in continuous complete local remission (CCLR). MATERIAL AND METHODS: From 1998 to 2010, 265 patients were treated with definitive EBRT +/− concomitant chemotherapy and IGABT. Twenty-four LRs were documented. For the statistical analysis all patients with LR were matched to patients in CCLR from our database according to the following criteria: FIGO stage, histology, lymph node status, tumour size and chemotherapy. DVH parameters (D50, D90, D98, D100) were reported for HR CTV and IR CTV. In order to report the minimum dose in the region where the recurrence occurred, the HR CTV/IR CTV were divided into four quadrants on transversal planes. The minimum dose at the HR CTV/IR CTV contour was measured (within the corresponding quadrant closest to the LR) in the treatment planning system. A mean minimum point dose (MPD) was calculated by averaging these measurements on four consecutive slices at the level of the recurrence for each of the 4 brachytherapy fractions. EQD2 doses were calculated by summation of all BT and external beam therapy fractions. For each matched patient in the control group the measurements were performed on the same quadrant and at the same level. RESULTS: Sufficient image data were available for 21 LRs. Eight central failures and 13 non-central failures were observed. The mean D90 and D100 for HR CTV were 77 Gy and 61 Gy for patients with LR and 95 Gy and 71 Gy for patients in CCLR, respectively (p < 0.01). The MPD for HR CTV was 72 Gy for patients in the LR arm and 99 Gy for patients in the CCLR arm (p < 0.01). In the LR arm seven patients had a D90 for HR CTV ⩾87 Gy, however, in only three patients the MPD was ⩾87 Gy. CONCLUSION: This study demonstrated significant differences in local outcome according to the delivered dose. In 85% of the LRs systematic low dose regions with less than 87 Gy were found at HR CTV contour. Systematic low dose regions leading to local recurrence could be detected even if a D90 HR CTV ⩾87 Gy was applied. In addition to DVH parameters, inspection of the spatial dose distribution remains a key point in dose prescription. Elsevier Scientific Publishers 2011-09 /pmc/articles/PMC3200439/ /pubmed/21924510 http://dx.doi.org/10.1016/j.radonc.2011.08.014 Text en © 2011 Elsevier Ireland Ltd. https://creativecommons.org/licenses/by-nc-nd/3.0/ Open Access under CC BY-NC-ND 3.0 (https://creativecommons.org/licenses/by-nc-nd/3.0/) license
spellingShingle Brachytherapy
Schmid, Maximilian P.
Kirisits, Christian
Nesvacil, Nicole
Dimopoulos, Johannes C.A.
Berger, Daniel
Pötter, Richard
Local recurrences in cervical cancer patients in the setting of image-guided brachytherapy: A comparison of spatial dose distribution within a matched-pair analysis
title Local recurrences in cervical cancer patients in the setting of image-guided brachytherapy: A comparison of spatial dose distribution within a matched-pair analysis
title_full Local recurrences in cervical cancer patients in the setting of image-guided brachytherapy: A comparison of spatial dose distribution within a matched-pair analysis
title_fullStr Local recurrences in cervical cancer patients in the setting of image-guided brachytherapy: A comparison of spatial dose distribution within a matched-pair analysis
title_full_unstemmed Local recurrences in cervical cancer patients in the setting of image-guided brachytherapy: A comparison of spatial dose distribution within a matched-pair analysis
title_short Local recurrences in cervical cancer patients in the setting of image-guided brachytherapy: A comparison of spatial dose distribution within a matched-pair analysis
title_sort local recurrences in cervical cancer patients in the setting of image-guided brachytherapy: a comparison of spatial dose distribution within a matched-pair analysis
topic Brachytherapy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3200439/
https://www.ncbi.nlm.nih.gov/pubmed/21924510
http://dx.doi.org/10.1016/j.radonc.2011.08.014
work_keys_str_mv AT schmidmaximilianp localrecurrencesincervicalcancerpatientsinthesettingofimageguidedbrachytherapyacomparisonofspatialdosedistributionwithinamatchedpairanalysis
AT kirisitschristian localrecurrencesincervicalcancerpatientsinthesettingofimageguidedbrachytherapyacomparisonofspatialdosedistributionwithinamatchedpairanalysis
AT nesvacilnicole localrecurrencesincervicalcancerpatientsinthesettingofimageguidedbrachytherapyacomparisonofspatialdosedistributionwithinamatchedpairanalysis
AT dimopoulosjohannesca localrecurrencesincervicalcancerpatientsinthesettingofimageguidedbrachytherapyacomparisonofspatialdosedistributionwithinamatchedpairanalysis
AT bergerdaniel localrecurrencesincervicalcancerpatientsinthesettingofimageguidedbrachytherapyacomparisonofspatialdosedistributionwithinamatchedpairanalysis
AT potterrichard localrecurrencesincervicalcancerpatientsinthesettingofimageguidedbrachytherapyacomparisonofspatialdosedistributionwithinamatchedpairanalysis