Cargando…
Designing the Vocal Alarm and improving medical ventilator
BACKGROUND: Today, as many as 1.5 million Americans use ventilators once in a year. Response to mechanical ventilation alarms remains to be one of the most challenging tasks facing physicians, nurses or other medical personnel in the ICU. In the present study we aimed to compare the response times t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications Pvt Ltd
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3203296/ https://www.ncbi.nlm.nih.gov/pubmed/22039376 |
_version_ | 1782215103860441088 |
---|---|
author | Mojdeh, Soheila Sadri, AliReza Nabii, MohammadMehdi Emadian, Hossein Rahimi, Mojtaba |
author_facet | Mojdeh, Soheila Sadri, AliReza Nabii, MohammadMehdi Emadian, Hossein Rahimi, Mojtaba |
author_sort | Mojdeh, Soheila |
collection | PubMed |
description | BACKGROUND: Today, as many as 1.5 million Americans use ventilators once in a year. Response to mechanical ventilation alarms remains to be one of the most challenging tasks facing physicians, nurses or other medical personnel in the ICU. In the present study we aimed to compare the response times to “vocal alarms” and “visual or audible ones”. METHODS: In the present study we developed a system to evaluate the “Vocal Alarm” and improve the medical ventilator “Benet 7200 Alarms” with it. Ventilator generates the alarms when patient has any problem. The time of Activation & Deactivation is recorded. The survey was done in central ICU for six days, 3 days with vocal alarm, and 3days with “Beep” alarms and detected Alarm events then recorded seventy-two hours of data for each type of alarms. All of events information saved in the memory and SPSS was used to determine difference between two types of alarms. RESULTS: On the average, the duration of the ventilator alarms activation were 33 ± 21 seconds for vocal alarms and 60 ± 46 for audible “Beep” alarms. The response times for vocal alarms were significantly lower (P = 0.001). CONCLUSIONS: The response times for normal “Beep” alarms were longer than vocal alarms. |
format | Online Article Text |
id | pubmed-3203296 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Medknow Publications Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-32032962011-10-28 Designing the Vocal Alarm and improving medical ventilator Mojdeh, Soheila Sadri, AliReza Nabii, MohammadMehdi Emadian, Hossein Rahimi, Mojtaba Iran J Nurs Midwifery Res Original Article BACKGROUND: Today, as many as 1.5 million Americans use ventilators once in a year. Response to mechanical ventilation alarms remains to be one of the most challenging tasks facing physicians, nurses or other medical personnel in the ICU. In the present study we aimed to compare the response times to “vocal alarms” and “visual or audible ones”. METHODS: In the present study we developed a system to evaluate the “Vocal Alarm” and improve the medical ventilator “Benet 7200 Alarms” with it. Ventilator generates the alarms when patient has any problem. The time of Activation & Deactivation is recorded. The survey was done in central ICU for six days, 3 days with vocal alarm, and 3days with “Beep” alarms and detected Alarm events then recorded seventy-two hours of data for each type of alarms. All of events information saved in the memory and SPSS was used to determine difference between two types of alarms. RESULTS: On the average, the duration of the ventilator alarms activation were 33 ± 21 seconds for vocal alarms and 60 ± 46 for audible “Beep” alarms. The response times for vocal alarms were significantly lower (P = 0.001). CONCLUSIONS: The response times for normal “Beep” alarms were longer than vocal alarms. Medknow Publications Pvt Ltd 2011 /pmc/articles/PMC3203296/ /pubmed/22039376 Text en Copyright: © Iranian Journal of Nursing and Midwifery Research http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Mojdeh, Soheila Sadri, AliReza Nabii, MohammadMehdi Emadian, Hossein Rahimi, Mojtaba Designing the Vocal Alarm and improving medical ventilator |
title | Designing the Vocal Alarm and improving medical ventilator |
title_full | Designing the Vocal Alarm and improving medical ventilator |
title_fullStr | Designing the Vocal Alarm and improving medical ventilator |
title_full_unstemmed | Designing the Vocal Alarm and improving medical ventilator |
title_short | Designing the Vocal Alarm and improving medical ventilator |
title_sort | designing the vocal alarm and improving medical ventilator |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3203296/ https://www.ncbi.nlm.nih.gov/pubmed/22039376 |
work_keys_str_mv | AT mojdehsoheila designingthevocalalarmandimprovingmedicalventilator AT sadrialireza designingthevocalalarmandimprovingmedicalventilator AT nabiimohammadmehdi designingthevocalalarmandimprovingmedicalventilator AT emadianhossein designingthevocalalarmandimprovingmedicalventilator AT rahimimojtaba designingthevocalalarmandimprovingmedicalventilator |