Cargando…

Designing the Vocal Alarm and improving medical ventilator

BACKGROUND: Today, as many as 1.5 million Americans use ventilators once in a year. Response to mechanical ventilation alarms remains to be one of the most challenging tasks facing physicians, nurses or other medical personnel in the ICU. In the present study we aimed to compare the response times t...

Descripción completa

Detalles Bibliográficos
Autores principales: Mojdeh, Soheila, Sadri, AliReza, Nabii, MohammadMehdi, Emadian, Hossein, Rahimi, Mojtaba
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3203296/
https://www.ncbi.nlm.nih.gov/pubmed/22039376
_version_ 1782215103860441088
author Mojdeh, Soheila
Sadri, AliReza
Nabii, MohammadMehdi
Emadian, Hossein
Rahimi, Mojtaba
author_facet Mojdeh, Soheila
Sadri, AliReza
Nabii, MohammadMehdi
Emadian, Hossein
Rahimi, Mojtaba
author_sort Mojdeh, Soheila
collection PubMed
description BACKGROUND: Today, as many as 1.5 million Americans use ventilators once in a year. Response to mechanical ventilation alarms remains to be one of the most challenging tasks facing physicians, nurses or other medical personnel in the ICU. In the present study we aimed to compare the response times to “vocal alarms” and “visual or audible ones”. METHODS: In the present study we developed a system to evaluate the “Vocal Alarm” and improve the medical ventilator “Benet 7200 Alarms” with it. Ventilator generates the alarms when patient has any problem. The time of Activation & Deactivation is recorded. The survey was done in central ICU for six days, 3 days with vocal alarm, and 3days with “Beep” alarms and detected Alarm events then recorded seventy-two hours of data for each type of alarms. All of events information saved in the memory and SPSS was used to determine difference between two types of alarms. RESULTS: On the average, the duration of the ventilator alarms activation were 33 ± 21 seconds for vocal alarms and 60 ± 46 for audible “Beep” alarms. The response times for vocal alarms were significantly lower (P = 0.001). CONCLUSIONS: The response times for normal “Beep” alarms were longer than vocal alarms.
format Online
Article
Text
id pubmed-3203296
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-32032962011-10-28 Designing the Vocal Alarm and improving medical ventilator Mojdeh, Soheila Sadri, AliReza Nabii, MohammadMehdi Emadian, Hossein Rahimi, Mojtaba Iran J Nurs Midwifery Res Original Article BACKGROUND: Today, as many as 1.5 million Americans use ventilators once in a year. Response to mechanical ventilation alarms remains to be one of the most challenging tasks facing physicians, nurses or other medical personnel in the ICU. In the present study we aimed to compare the response times to “vocal alarms” and “visual or audible ones”. METHODS: In the present study we developed a system to evaluate the “Vocal Alarm” and improve the medical ventilator “Benet 7200 Alarms” with it. Ventilator generates the alarms when patient has any problem. The time of Activation & Deactivation is recorded. The survey was done in central ICU for six days, 3 days with vocal alarm, and 3days with “Beep” alarms and detected Alarm events then recorded seventy-two hours of data for each type of alarms. All of events information saved in the memory and SPSS was used to determine difference between two types of alarms. RESULTS: On the average, the duration of the ventilator alarms activation were 33 ± 21 seconds for vocal alarms and 60 ± 46 for audible “Beep” alarms. The response times for vocal alarms were significantly lower (P = 0.001). CONCLUSIONS: The response times for normal “Beep” alarms were longer than vocal alarms. Medknow Publications Pvt Ltd 2011 /pmc/articles/PMC3203296/ /pubmed/22039376 Text en Copyright: © Iranian Journal of Nursing and Midwifery Research http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Mojdeh, Soheila
Sadri, AliReza
Nabii, MohammadMehdi
Emadian, Hossein
Rahimi, Mojtaba
Designing the Vocal Alarm and improving medical ventilator
title Designing the Vocal Alarm and improving medical ventilator
title_full Designing the Vocal Alarm and improving medical ventilator
title_fullStr Designing the Vocal Alarm and improving medical ventilator
title_full_unstemmed Designing the Vocal Alarm and improving medical ventilator
title_short Designing the Vocal Alarm and improving medical ventilator
title_sort designing the vocal alarm and improving medical ventilator
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3203296/
https://www.ncbi.nlm.nih.gov/pubmed/22039376
work_keys_str_mv AT mojdehsoheila designingthevocalalarmandimprovingmedicalventilator
AT sadrialireza designingthevocalalarmandimprovingmedicalventilator
AT nabiimohammadmehdi designingthevocalalarmandimprovingmedicalventilator
AT emadianhossein designingthevocalalarmandimprovingmedicalventilator
AT rahimimojtaba designingthevocalalarmandimprovingmedicalventilator