Cargando…

Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading

PURPOSE: Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading. MATERIALS AND METHODS: Two dimensional finite element models of cylinderical implant, abutments and bone made by titanium or polyoxymethylene were simulated with the aid of...

Descripción completa

Detalles Bibliográficos
Autores principales: Mishra, Manish, Ozawa, Shogo, Masuda, Tatsuhiko, Yoshioka, Fumi, Tanaka, Yoshinobu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3204450/
https://www.ncbi.nlm.nih.gov/pubmed/22053245
http://dx.doi.org/10.4047/jap.2011.3.3.140