Cargando…

Placental Plasmodium falciparum malaria infection: Operational accuracy of HRP2 rapid diagnostic tests in a malaria endemic setting

BACKGROUND: Malaria has a negative effect on the outcome of pregnancy. Pregnant women are at high risk of severe malaria and severe haemolytic anaemia, which contribute 60-70% of foetal and perinatal losses. Peripheral blood smear microscopy under-estimates sequestered placental infections, therefor...

Descripción completa

Detalles Bibliográficos
Autores principales: Kyabayinze, Daniel J, Tibenderana, James K, Nassali, Mercy, Tumwine, Lynette K, Riches, Clare, Montague, Mark, Counihan, Helen, Hamade, Prudence, Van Geertruyden, Jean-Pierre, Meek, Sylvia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3206496/
https://www.ncbi.nlm.nih.gov/pubmed/22004666
http://dx.doi.org/10.1186/1475-2875-10-306
_version_ 1782215447729405952
author Kyabayinze, Daniel J
Tibenderana, James K
Nassali, Mercy
Tumwine, Lynette K
Riches, Clare
Montague, Mark
Counihan, Helen
Hamade, Prudence
Van Geertruyden, Jean-Pierre
Meek, Sylvia
author_facet Kyabayinze, Daniel J
Tibenderana, James K
Nassali, Mercy
Tumwine, Lynette K
Riches, Clare
Montague, Mark
Counihan, Helen
Hamade, Prudence
Van Geertruyden, Jean-Pierre
Meek, Sylvia
author_sort Kyabayinze, Daniel J
collection PubMed
description BACKGROUND: Malaria has a negative effect on the outcome of pregnancy. Pregnant women are at high risk of severe malaria and severe haemolytic anaemia, which contribute 60-70% of foetal and perinatal losses. Peripheral blood smear microscopy under-estimates sequestered placental infections, therefore malaria rapid diagnostic tests (RDTs) detecting histidine rich protein-2 antigen (HRP-2) in peripheral blood are a potential alternative. METHODS: HRP-2 RDTs accuracy in detecting malaria in pregnancy (MIP >28 weeks gestation) and placental Plasmodium falciparum malaria (after childbirth) were conducted using Giemsa microscopy and placental histopathology respectively as the reference standard. The study was conducted in Mbale Hospital, using the midwives to perform and interpret the RDT results. Discordant results samples were spot checked using PCR techniques. RESULTS: Among 433 febrile women tested, RDTs had a sensitivity of 96.8% (95% CI 92-98.8), specificity of 73.5% (95% CI 67.8-78.6), a positive predictive value (PPV) of 68.0% (95% CI 61.4-73.9), and negative predictive value (NPV) of 97.5% (95% CI 94.0-99.0) in detecting peripheral P. falciparum malaria during pregnancy. At delivery, in non-symptomatic women, RDTs had a 80.9% sensitivity (95% CI 57.4-93.7) and a 87.5% specificity (95%CI 80.9-92.1), PPV of 47.2% (95% CI 30.7-64.2) and NPV of 97.1% (95% CI 92.2-99.1) in detecting placental P. falciparum infections among 173 samples. At delivery, 41% of peripheral infections were detected by microscopy without concurrent placental infection. The combination of RDTs and microscopy improved the sensitivity to 90.5% and the specificity to 98.4% for detecting placental malaria infection (McNemar's X (2)> 3.84). RDTs were not superior to microscopy in detecting placental infection (McNemar's X (2)< 3.84). Presence of malaria in pregnancy and active placental malaria infection were 38% and 12% respectively. Placental infections were associated with poor pregnancy outcome [pre-term, still birth and low birth weight] (aOR = 37.9) and late pregnancy malaria infection (aOR = 20.9). Mosquito net use (aOR 2.1) and increasing parity (aOR 2.7) were associated with lower risk for malaria in pregnancy. CONCLUSION: Use of HRP-2 RDTs to detect malaria in pregnancy in symptomatic women was accurate when performed by midwives. A combination of RDTs and microscopy provided the best means of detecting placental malaria. RDTs were not superior to microscopy in detecting placental infection. With a high sensitivity and specificity, RDTs could be a useful tool for assessing malaria in pregnancy, with further (cost-) effectiveness studies.
format Online
Article
Text
id pubmed-3206496
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32064962011-11-03 Placental Plasmodium falciparum malaria infection: Operational accuracy of HRP2 rapid diagnostic tests in a malaria endemic setting Kyabayinze, Daniel J Tibenderana, James K Nassali, Mercy Tumwine, Lynette K Riches, Clare Montague, Mark Counihan, Helen Hamade, Prudence Van Geertruyden, Jean-Pierre Meek, Sylvia Malar J Research BACKGROUND: Malaria has a negative effect on the outcome of pregnancy. Pregnant women are at high risk of severe malaria and severe haemolytic anaemia, which contribute 60-70% of foetal and perinatal losses. Peripheral blood smear microscopy under-estimates sequestered placental infections, therefore malaria rapid diagnostic tests (RDTs) detecting histidine rich protein-2 antigen (HRP-2) in peripheral blood are a potential alternative. METHODS: HRP-2 RDTs accuracy in detecting malaria in pregnancy (MIP >28 weeks gestation) and placental Plasmodium falciparum malaria (after childbirth) were conducted using Giemsa microscopy and placental histopathology respectively as the reference standard. The study was conducted in Mbale Hospital, using the midwives to perform and interpret the RDT results. Discordant results samples were spot checked using PCR techniques. RESULTS: Among 433 febrile women tested, RDTs had a sensitivity of 96.8% (95% CI 92-98.8), specificity of 73.5% (95% CI 67.8-78.6), a positive predictive value (PPV) of 68.0% (95% CI 61.4-73.9), and negative predictive value (NPV) of 97.5% (95% CI 94.0-99.0) in detecting peripheral P. falciparum malaria during pregnancy. At delivery, in non-symptomatic women, RDTs had a 80.9% sensitivity (95% CI 57.4-93.7) and a 87.5% specificity (95%CI 80.9-92.1), PPV of 47.2% (95% CI 30.7-64.2) and NPV of 97.1% (95% CI 92.2-99.1) in detecting placental P. falciparum infections among 173 samples. At delivery, 41% of peripheral infections were detected by microscopy without concurrent placental infection. The combination of RDTs and microscopy improved the sensitivity to 90.5% and the specificity to 98.4% for detecting placental malaria infection (McNemar's X (2)> 3.84). RDTs were not superior to microscopy in detecting placental infection (McNemar's X (2)< 3.84). Presence of malaria in pregnancy and active placental malaria infection were 38% and 12% respectively. Placental infections were associated with poor pregnancy outcome [pre-term, still birth and low birth weight] (aOR = 37.9) and late pregnancy malaria infection (aOR = 20.9). Mosquito net use (aOR 2.1) and increasing parity (aOR 2.7) were associated with lower risk for malaria in pregnancy. CONCLUSION: Use of HRP-2 RDTs to detect malaria in pregnancy in symptomatic women was accurate when performed by midwives. A combination of RDTs and microscopy provided the best means of detecting placental malaria. RDTs were not superior to microscopy in detecting placental infection. With a high sensitivity and specificity, RDTs could be a useful tool for assessing malaria in pregnancy, with further (cost-) effectiveness studies. BioMed Central 2011-10-18 /pmc/articles/PMC3206496/ /pubmed/22004666 http://dx.doi.org/10.1186/1475-2875-10-306 Text en Copyright ©2011 Kyabayinze et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Kyabayinze, Daniel J
Tibenderana, James K
Nassali, Mercy
Tumwine, Lynette K
Riches, Clare
Montague, Mark
Counihan, Helen
Hamade, Prudence
Van Geertruyden, Jean-Pierre
Meek, Sylvia
Placental Plasmodium falciparum malaria infection: Operational accuracy of HRP2 rapid diagnostic tests in a malaria endemic setting
title Placental Plasmodium falciparum malaria infection: Operational accuracy of HRP2 rapid diagnostic tests in a malaria endemic setting
title_full Placental Plasmodium falciparum malaria infection: Operational accuracy of HRP2 rapid diagnostic tests in a malaria endemic setting
title_fullStr Placental Plasmodium falciparum malaria infection: Operational accuracy of HRP2 rapid diagnostic tests in a malaria endemic setting
title_full_unstemmed Placental Plasmodium falciparum malaria infection: Operational accuracy of HRP2 rapid diagnostic tests in a malaria endemic setting
title_short Placental Plasmodium falciparum malaria infection: Operational accuracy of HRP2 rapid diagnostic tests in a malaria endemic setting
title_sort placental plasmodium falciparum malaria infection: operational accuracy of hrp2 rapid diagnostic tests in a malaria endemic setting
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3206496/
https://www.ncbi.nlm.nih.gov/pubmed/22004666
http://dx.doi.org/10.1186/1475-2875-10-306
work_keys_str_mv AT kyabayinzedanielj placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting
AT tibenderanajamesk placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting
AT nassalimercy placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting
AT tumwinelynettek placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting
AT richesclare placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting
AT montaguemark placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting
AT counihanhelen placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting
AT hamadeprudence placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting
AT vangeertruydenjeanpierre placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting
AT meeksylvia placentalplasmodiumfalciparummalariainfectionoperationalaccuracyofhrp2rapiddiagnostictestsinamalariaendemicsetting