Cargando…

DPO multiplex PCR as an alternative to culture and susceptibility testing to detect Helicobacter pylori and its resistance to clarithromycin

BACKGROUND: Macrolide resistance in Helicobacter pylori is the major risk factor for treatment failure when using a proton pump inhibitor-clarithromycin containing therapy. Macrolide resistance is due to a few mutations on the 23S ribomosal subunit encoded by the 23S rRNA gene. The present study aim...

Descripción completa

Detalles Bibliográficos
Autores principales: Lehours, Philippe, Siffré, Elodie, Mégraud , Francis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3206832/
https://www.ncbi.nlm.nih.gov/pubmed/22004003
http://dx.doi.org/10.1186/1471-230X-11-112
_version_ 1782215490840559616
author Lehours, Philippe
Siffré, Elodie
Mégraud , Francis
author_facet Lehours, Philippe
Siffré, Elodie
Mégraud , Francis
author_sort Lehours, Philippe
collection PubMed
description BACKGROUND: Macrolide resistance in Helicobacter pylori is the major risk factor for treatment failure when using a proton pump inhibitor-clarithromycin containing therapy. Macrolide resistance is due to a few mutations on the 23S ribomosal subunit encoded by the 23S rRNA gene. The present study aimed at investigating the performance of the dual priming oligonucleotide (DPO)-PCR kit named Seeplex(® )ClaR-H. pylori ACE detection designed to detect H. pylori and two types of point mutations causing clarithromycin resistance in H. pylori. METHODS: The performance of Seeplex(® )ClaR-H. pylori ACE detection was evaluated on 127 gastric biopsies in comparison to conventional bacterial culture followed by the determination of susceptibility to clarithromycin by E-test, as well as by an in-house real-time PCR using a fluorescence resonance energy transfer (FRET) technology. RESULTS: Considering culture as the reference test, the sensitivity of DPO-PCR and real-time FRET-PCR was 97.7% and 100% while specificity was 83.1% and 80.7%, respectively. However, both PCR were concordant in detecting 14 H. pylori positive cases which were negative by culture. Globally, E-test and DPO-PCR were concordant with regard to clarithromycin susceptibility in 95.3% of the cases (41/43), while real-time FRET-PCR and DPO-PCR were concordant in 95% (57/60). CONCLUSION: The DPO-PCR is an interesting tool to detect H. pylori on gastric biopsies and to study its susceptibility to clarithromycin in laboratories that cannot perform real-time PCR assays.
format Online
Article
Text
id pubmed-3206832
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32068322011-11-03 DPO multiplex PCR as an alternative to culture and susceptibility testing to detect Helicobacter pylori and its resistance to clarithromycin Lehours, Philippe Siffré, Elodie Mégraud , Francis BMC Gastroenterol Research Article BACKGROUND: Macrolide resistance in Helicobacter pylori is the major risk factor for treatment failure when using a proton pump inhibitor-clarithromycin containing therapy. Macrolide resistance is due to a few mutations on the 23S ribomosal subunit encoded by the 23S rRNA gene. The present study aimed at investigating the performance of the dual priming oligonucleotide (DPO)-PCR kit named Seeplex(® )ClaR-H. pylori ACE detection designed to detect H. pylori and two types of point mutations causing clarithromycin resistance in H. pylori. METHODS: The performance of Seeplex(® )ClaR-H. pylori ACE detection was evaluated on 127 gastric biopsies in comparison to conventional bacterial culture followed by the determination of susceptibility to clarithromycin by E-test, as well as by an in-house real-time PCR using a fluorescence resonance energy transfer (FRET) technology. RESULTS: Considering culture as the reference test, the sensitivity of DPO-PCR and real-time FRET-PCR was 97.7% and 100% while specificity was 83.1% and 80.7%, respectively. However, both PCR were concordant in detecting 14 H. pylori positive cases which were negative by culture. Globally, E-test and DPO-PCR were concordant with regard to clarithromycin susceptibility in 95.3% of the cases (41/43), while real-time FRET-PCR and DPO-PCR were concordant in 95% (57/60). CONCLUSION: The DPO-PCR is an interesting tool to detect H. pylori on gastric biopsies and to study its susceptibility to clarithromycin in laboratories that cannot perform real-time PCR assays. BioMed Central 2011-10-17 /pmc/articles/PMC3206832/ /pubmed/22004003 http://dx.doi.org/10.1186/1471-230X-11-112 Text en Copyright ©2011 Lehours et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Lehours, Philippe
Siffré, Elodie
Mégraud , Francis
DPO multiplex PCR as an alternative to culture and susceptibility testing to detect Helicobacter pylori and its resistance to clarithromycin
title DPO multiplex PCR as an alternative to culture and susceptibility testing to detect Helicobacter pylori and its resistance to clarithromycin
title_full DPO multiplex PCR as an alternative to culture and susceptibility testing to detect Helicobacter pylori and its resistance to clarithromycin
title_fullStr DPO multiplex PCR as an alternative to culture and susceptibility testing to detect Helicobacter pylori and its resistance to clarithromycin
title_full_unstemmed DPO multiplex PCR as an alternative to culture and susceptibility testing to detect Helicobacter pylori and its resistance to clarithromycin
title_short DPO multiplex PCR as an alternative to culture and susceptibility testing to detect Helicobacter pylori and its resistance to clarithromycin
title_sort dpo multiplex pcr as an alternative to culture and susceptibility testing to detect helicobacter pylori and its resistance to clarithromycin
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3206832/
https://www.ncbi.nlm.nih.gov/pubmed/22004003
http://dx.doi.org/10.1186/1471-230X-11-112
work_keys_str_mv AT lehoursphilippe dpomultiplexpcrasanalternativetocultureandsusceptibilitytestingtodetecthelicobacterpylorianditsresistancetoclarithromycin
AT siffreelodie dpomultiplexpcrasanalternativetocultureandsusceptibilitytestingtodetecthelicobacterpylorianditsresistancetoclarithromycin
AT megraudfrancis dpomultiplexpcrasanalternativetocultureandsusceptibilitytestingtodetecthelicobacterpylorianditsresistancetoclarithromycin