Cargando…

Imaging workflow and calibration for CT-guided time-domain fluorescence tomography

In this study, several key optimization steps are outlined for a non-contact, time-correlated single photon counting small animal optical tomography system, using simultaneous collection of both fluorescence and transmittance data. The system is presented for time-domain image reconstruction in vivo...

Descripción completa

Detalles Bibliográficos
Autores principales: Tichauer, Kenneth M., Holt, Robert W., El-Ghussein, Fadi, Zhu, Qun, Dehghani, Hamid, Leblond, Frederic, Pogue, Brian W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3207372/
https://www.ncbi.nlm.nih.gov/pubmed/22076264
http://dx.doi.org/10.1364/BOE.2.003021
_version_ 1782215541902016512
author Tichauer, Kenneth M.
Holt, Robert W.
El-Ghussein, Fadi
Zhu, Qun
Dehghani, Hamid
Leblond, Frederic
Pogue, Brian W.
author_facet Tichauer, Kenneth M.
Holt, Robert W.
El-Ghussein, Fadi
Zhu, Qun
Dehghani, Hamid
Leblond, Frederic
Pogue, Brian W.
author_sort Tichauer, Kenneth M.
collection PubMed
description In this study, several key optimization steps are outlined for a non-contact, time-correlated single photon counting small animal optical tomography system, using simultaneous collection of both fluorescence and transmittance data. The system is presented for time-domain image reconstruction in vivo, illustrating the sensitivity from single photon counting and the calibration steps needed to accurately process the data. In particular, laser time- and amplitude-referencing, detector and filter calibrations, and collection of a suitable instrument response function are all presented in the context of time-domain fluorescence tomography and a fully automated workflow is described. Preliminary phantom time-domain reconstructed images demonstrate the fidelity of the workflow for fluorescence tomography based on signal from multiple time gates.
format Online
Article
Text
id pubmed-3207372
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-32073722011-11-10 Imaging workflow and calibration for CT-guided time-domain fluorescence tomography Tichauer, Kenneth M. Holt, Robert W. El-Ghussein, Fadi Zhu, Qun Dehghani, Hamid Leblond, Frederic Pogue, Brian W. Biomed Opt Express Diffuse Optical Imaging In this study, several key optimization steps are outlined for a non-contact, time-correlated single photon counting small animal optical tomography system, using simultaneous collection of both fluorescence and transmittance data. The system is presented for time-domain image reconstruction in vivo, illustrating the sensitivity from single photon counting and the calibration steps needed to accurately process the data. In particular, laser time- and amplitude-referencing, detector and filter calibrations, and collection of a suitable instrument response function are all presented in the context of time-domain fluorescence tomography and a fully automated workflow is described. Preliminary phantom time-domain reconstructed images demonstrate the fidelity of the workflow for fluorescence tomography based on signal from multiple time gates. Optical Society of America 2011-10-05 /pmc/articles/PMC3207372/ /pubmed/22076264 http://dx.doi.org/10.1364/BOE.2.003021 Text en ©2011 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially.
spellingShingle Diffuse Optical Imaging
Tichauer, Kenneth M.
Holt, Robert W.
El-Ghussein, Fadi
Zhu, Qun
Dehghani, Hamid
Leblond, Frederic
Pogue, Brian W.
Imaging workflow and calibration for CT-guided time-domain fluorescence tomography
title Imaging workflow and calibration for CT-guided time-domain fluorescence tomography
title_full Imaging workflow and calibration for CT-guided time-domain fluorescence tomography
title_fullStr Imaging workflow and calibration for CT-guided time-domain fluorescence tomography
title_full_unstemmed Imaging workflow and calibration for CT-guided time-domain fluorescence tomography
title_short Imaging workflow and calibration for CT-guided time-domain fluorescence tomography
title_sort imaging workflow and calibration for ct-guided time-domain fluorescence tomography
topic Diffuse Optical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3207372/
https://www.ncbi.nlm.nih.gov/pubmed/22076264
http://dx.doi.org/10.1364/BOE.2.003021
work_keys_str_mv AT tichauerkennethm imagingworkflowandcalibrationforctguidedtimedomainfluorescencetomography
AT holtrobertw imagingworkflowandcalibrationforctguidedtimedomainfluorescencetomography
AT elghusseinfadi imagingworkflowandcalibrationforctguidedtimedomainfluorescencetomography
AT zhuqun imagingworkflowandcalibrationforctguidedtimedomainfluorescencetomography
AT dehghanihamid imagingworkflowandcalibrationforctguidedtimedomainfluorescencetomography
AT leblondfrederic imagingworkflowandcalibrationforctguidedtimedomainfluorescencetomography
AT poguebrianw imagingworkflowandcalibrationforctguidedtimedomainfluorescencetomography