Cargando…
Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT)
PURPOSE: To analyze the differences between the intensity-modulated radiotherapy (IMRT), single/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) techniques in treatment planning for locally advanced lung cancer. MATERIALS AND METHODS: 12 patients were retrospectively studied. In each patien...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3207896/ https://www.ncbi.nlm.nih.gov/pubmed/22014217 http://dx.doi.org/10.1186/1748-717X-6-140 |
_version_ | 1782215572063256576 |
---|---|
author | Jiang, Xiaoqin Li, Tao Liu, Yongmei Zhou, Lin Xu, Yong Zhou, Xiaojuan Gong, Youling |
author_facet | Jiang, Xiaoqin Li, Tao Liu, Yongmei Zhou, Lin Xu, Yong Zhou, Xiaojuan Gong, Youling |
author_sort | Jiang, Xiaoqin |
collection | PubMed |
description | PURPOSE: To analyze the differences between the intensity-modulated radiotherapy (IMRT), single/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) techniques in treatment planning for locally advanced lung cancer. MATERIALS AND METHODS: 12 patients were retrospectively studied. In each patient's case, several parameters were analyzed based on the dose-volume histograms (DVH) of the IMRT, SA/PA-VMAT plans respectively. Also, each plan was delivered to a phantom for time comparison. RESULTS: The SA-VMAT plans showed the superior target dose coverage, although the minimum/mean/maximum doses to the target were similar. For the total and contralateral lungs, the higher V(5/10), lower V(20/30 )and mean lung dose (MLD) were observed in the SA/PA-VMAT plans (p < 0.05, respectively). The PA-VMAT technique improves the dose sparing (V(20), V(30 )and MLD) of the controlateral lung more notably, comparing to those parameters of the IMRT and SA-VMAT plans respectively. The delivered monitor units (MUs) and treatment times were reduced significantly with VMAT plans, especially PA-VMAT plans (for MUs: mean 458.3 vs. 439.2 vs. 435.7 MUs, p < 0.05 and for treatment time: mean 13.7 vs. 10.6 vs. 6.4 minutes, p < 0.01). CONCLUSIONS: The SA-VMAT technique achieves highly conformal dose distribution to the target. Comparing to the IMRT plans, the higher V(5/10), lower V(20/30 )and MLD were observed in the total and contralateral lungs in the VMAT plans, especially in the PA-VMAT plans. The SA/PA-VMAT plans also reduced treatment time with more efficient dose delivering. But the clinical benefit of the VMAT technique for locally advanced lung cancer needs further investigations. |
format | Online Article Text |
id | pubmed-3207896 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-32078962011-11-04 Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) Jiang, Xiaoqin Li, Tao Liu, Yongmei Zhou, Lin Xu, Yong Zhou, Xiaojuan Gong, Youling Radiat Oncol Research PURPOSE: To analyze the differences between the intensity-modulated radiotherapy (IMRT), single/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) techniques in treatment planning for locally advanced lung cancer. MATERIALS AND METHODS: 12 patients were retrospectively studied. In each patient's case, several parameters were analyzed based on the dose-volume histograms (DVH) of the IMRT, SA/PA-VMAT plans respectively. Also, each plan was delivered to a phantom for time comparison. RESULTS: The SA-VMAT plans showed the superior target dose coverage, although the minimum/mean/maximum doses to the target were similar. For the total and contralateral lungs, the higher V(5/10), lower V(20/30 )and mean lung dose (MLD) were observed in the SA/PA-VMAT plans (p < 0.05, respectively). The PA-VMAT technique improves the dose sparing (V(20), V(30 )and MLD) of the controlateral lung more notably, comparing to those parameters of the IMRT and SA-VMAT plans respectively. The delivered monitor units (MUs) and treatment times were reduced significantly with VMAT plans, especially PA-VMAT plans (for MUs: mean 458.3 vs. 439.2 vs. 435.7 MUs, p < 0.05 and for treatment time: mean 13.7 vs. 10.6 vs. 6.4 minutes, p < 0.01). CONCLUSIONS: The SA-VMAT technique achieves highly conformal dose distribution to the target. Comparing to the IMRT plans, the higher V(5/10), lower V(20/30 )and MLD were observed in the total and contralateral lungs in the VMAT plans, especially in the PA-VMAT plans. The SA/PA-VMAT plans also reduced treatment time with more efficient dose delivering. But the clinical benefit of the VMAT technique for locally advanced lung cancer needs further investigations. BioMed Central 2011-10-21 /pmc/articles/PMC3207896/ /pubmed/22014217 http://dx.doi.org/10.1186/1748-717X-6-140 Text en Copyright ©2011 Jiang et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Jiang, Xiaoqin Li, Tao Liu, Yongmei Zhou, Lin Xu, Yong Zhou, Xiaojuan Gong, Youling Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) |
title | Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) |
title_full | Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) |
title_fullStr | Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) |
title_full_unstemmed | Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) |
title_short | Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) |
title_sort | planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (imrt), single-arc/partial-arc volumetric modulated arc therapy (sa/pa-vmat) |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3207896/ https://www.ncbi.nlm.nih.gov/pubmed/22014217 http://dx.doi.org/10.1186/1748-717X-6-140 |
work_keys_str_mv | AT jiangxiaoqin planninganalysisforlocallyadvancedlungcancerdosimetricandefficiencycomparisonsbetweenintensitymodulatedradiotherapyimrtsinglearcpartialarcvolumetricmodulatedarctherapysapavmat AT litao planninganalysisforlocallyadvancedlungcancerdosimetricandefficiencycomparisonsbetweenintensitymodulatedradiotherapyimrtsinglearcpartialarcvolumetricmodulatedarctherapysapavmat AT liuyongmei planninganalysisforlocallyadvancedlungcancerdosimetricandefficiencycomparisonsbetweenintensitymodulatedradiotherapyimrtsinglearcpartialarcvolumetricmodulatedarctherapysapavmat AT zhoulin planninganalysisforlocallyadvancedlungcancerdosimetricandefficiencycomparisonsbetweenintensitymodulatedradiotherapyimrtsinglearcpartialarcvolumetricmodulatedarctherapysapavmat AT xuyong planninganalysisforlocallyadvancedlungcancerdosimetricandefficiencycomparisonsbetweenintensitymodulatedradiotherapyimrtsinglearcpartialarcvolumetricmodulatedarctherapysapavmat AT zhouxiaojuan planninganalysisforlocallyadvancedlungcancerdosimetricandefficiencycomparisonsbetweenintensitymodulatedradiotherapyimrtsinglearcpartialarcvolumetricmodulatedarctherapysapavmat AT gongyouling planninganalysisforlocallyadvancedlungcancerdosimetricandefficiencycomparisonsbetweenintensitymodulatedradiotherapyimrtsinglearcpartialarcvolumetricmodulatedarctherapysapavmat |