An inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories
BACKGROUND: Biomarkers have been used extensively in clinical studies to assess toxicant exposure in smokers and non-smokers and have recently been used in the evaluation of novel tobacco products. The urinary metabolite 3-HPMA, a metabolite of the major tobacco smoke toxicity contributor acrolein,...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3208382/ https://www.ncbi.nlm.nih.gov/pubmed/21985092 http://dx.doi.org/10.1186/1756-0500-4-391 |
_version_ | 1782215608690016256 |
---|---|
author | Minet, Emmanuel Errington, Graham Scherer, Gerhard Newland, Kirk Sharifi, Mehran Bailey, Brian McEwan, Mike Cheung, Francis |
author_facet | Minet, Emmanuel Errington, Graham Scherer, Gerhard Newland, Kirk Sharifi, Mehran Bailey, Brian McEwan, Mike Cheung, Francis |
author_sort | Minet, Emmanuel |
collection | PubMed |
description | BACKGROUND: Biomarkers have been used extensively in clinical studies to assess toxicant exposure in smokers and non-smokers and have recently been used in the evaluation of novel tobacco products. The urinary metabolite 3-HPMA, a metabolite of the major tobacco smoke toxicity contributor acrolein, is one example of a biomarker used to measure exposure to tobacco smoke. A number of laboratories have developed liquid chromatography with tandem mass spectrometry (LC-MS/MS) based methods to measure urinary 3-HPMA; however, it is unclear to what extent the data obtained by these different laboratories are comparable. FINDINGS: This report describes an inter-laboratory comparison carried out to evaluate the comparability of 3-HPMA measurement between four laboratories. A common set of spiked and authentic smoker and non-smoker urine samples were used. Each laboratory used their in-house LC-MS/MS method and a common internal standard. A comparison of the repeatability ('r'), reproducibility ('R'), and coefficient of variation for 3-HPMA demonstrated that within-laboratory variation was consistently lower than between-laboratory variation. The average inter-laboratory coefficient of variation was 7% for fortified urine samples and 16.2% for authentic urine samples. Together, this represents an inter-laboratory variation of 12.2%. CONCLUSION: The results from this first inter-laboratory comparison for the measurement of 3-HPMA in urine demonstrate a reasonably good consensus between laboratories. However, some consistent measurement biases were still observed between laboratories, suggesting that additional work may be required to further reduce the inter-laboratory coefficient of variation. |
format | Online Article Text |
id | pubmed-3208382 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-32083822011-11-05 An inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories Minet, Emmanuel Errington, Graham Scherer, Gerhard Newland, Kirk Sharifi, Mehran Bailey, Brian McEwan, Mike Cheung, Francis BMC Res Notes Short Report BACKGROUND: Biomarkers have been used extensively in clinical studies to assess toxicant exposure in smokers and non-smokers and have recently been used in the evaluation of novel tobacco products. The urinary metabolite 3-HPMA, a metabolite of the major tobacco smoke toxicity contributor acrolein, is one example of a biomarker used to measure exposure to tobacco smoke. A number of laboratories have developed liquid chromatography with tandem mass spectrometry (LC-MS/MS) based methods to measure urinary 3-HPMA; however, it is unclear to what extent the data obtained by these different laboratories are comparable. FINDINGS: This report describes an inter-laboratory comparison carried out to evaluate the comparability of 3-HPMA measurement between four laboratories. A common set of spiked and authentic smoker and non-smoker urine samples were used. Each laboratory used their in-house LC-MS/MS method and a common internal standard. A comparison of the repeatability ('r'), reproducibility ('R'), and coefficient of variation for 3-HPMA demonstrated that within-laboratory variation was consistently lower than between-laboratory variation. The average inter-laboratory coefficient of variation was 7% for fortified urine samples and 16.2% for authentic urine samples. Together, this represents an inter-laboratory variation of 12.2%. CONCLUSION: The results from this first inter-laboratory comparison for the measurement of 3-HPMA in urine demonstrate a reasonably good consensus between laboratories. However, some consistent measurement biases were still observed between laboratories, suggesting that additional work may be required to further reduce the inter-laboratory coefficient of variation. BioMed Central 2011-10-10 /pmc/articles/PMC3208382/ /pubmed/21985092 http://dx.doi.org/10.1186/1756-0500-4-391 Text en Copyright ©2011 Minet et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Report Minet, Emmanuel Errington, Graham Scherer, Gerhard Newland, Kirk Sharifi, Mehran Bailey, Brian McEwan, Mike Cheung, Francis An inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories |
title | An inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories |
title_full | An inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories |
title_fullStr | An inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories |
title_full_unstemmed | An inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories |
title_short | An inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories |
title_sort | inter-laboratory comparison of urinary 3-hydroxypropylmercapturic acid measurement demonstrates good reproducibility between laboratories |
topic | Short Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3208382/ https://www.ncbi.nlm.nih.gov/pubmed/21985092 http://dx.doi.org/10.1186/1756-0500-4-391 |
work_keys_str_mv | AT minetemmanuel aninterlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT erringtongraham aninterlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT scherergerhard aninterlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT newlandkirk aninterlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT sharifimehran aninterlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT baileybrian aninterlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT mcewanmike aninterlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT cheungfrancis aninterlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT minetemmanuel interlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT erringtongraham interlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT scherergerhard interlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT newlandkirk interlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT sharifimehran interlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT baileybrian interlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT mcewanmike interlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories AT cheungfrancis interlaboratorycomparisonofurinary3hydroxypropylmercapturicacidmeasurementdemonstratesgoodreproducibilitybetweenlaboratories |