Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices

Polymethylmethacrylate (PMMA) microfluidic devices have been fabricated using a hot embossing technique to incorporate micro-pillar features on the bottom wall of the device which when combined with either a plasma treatment or the coating of a diamond-like carbon (DLC) film presents a range of surf...

Descripción completa

Detalles Bibliográficos
Autores principales: Mukhopadhyay, Subhadeep, Roy, Susanta S, D'Sa, Raechelle A, Mathur, Ashish, Holmes, Richard J, McLaughlin, James A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3211507/
https://www.ncbi.nlm.nih.gov/pubmed/21711936
http://dx.doi.org/10.1186/1556-276X-6-411
_version_ 1782215882457481216
author Mukhopadhyay, Subhadeep
Roy, Susanta S
D'Sa, Raechelle A
Mathur, Ashish
Holmes, Richard J
McLaughlin, James A
author_facet Mukhopadhyay, Subhadeep
Roy, Susanta S
D'Sa, Raechelle A
Mathur, Ashish
Holmes, Richard J
McLaughlin, James A
author_sort Mukhopadhyay, Subhadeep
collection PubMed
description Polymethylmethacrylate (PMMA) microfluidic devices have been fabricated using a hot embossing technique to incorporate micro-pillar features on the bottom wall of the device which when combined with either a plasma treatment or the coating of a diamond-like carbon (DLC) film presents a range of surface modification profiles. Experimental results presented in detail the surface modifications in the form of distinct changes in the static water contact angle across a range from 44.3 to 81.2 when compared to pristine PMMA surfaces. Additionally, capillary flow of water (dyed to aid visualization) through the microfluidic devices was recorded and analyzed to provide comparison data between filling time of a microfluidic chamber and surface modification characteristics, including the effects of surface energy and surface roughness on the microfluidic flow. We have experimentally demonstrated that fluid flow and thus filling time for the microfluidic device was significantly faster for the device with surface modifications that resulted in a lower static contact angle, and also that the incorporation of micro-pillars into a fluidic device increases the filling time when compared to comparative devices.
format Online
Article
Text
id pubmed-3211507
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-32115072011-11-09 Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices Mukhopadhyay, Subhadeep Roy, Susanta S D'Sa, Raechelle A Mathur, Ashish Holmes, Richard J McLaughlin, James A Nanoscale Res Lett Nano Idea Polymethylmethacrylate (PMMA) microfluidic devices have been fabricated using a hot embossing technique to incorporate micro-pillar features on the bottom wall of the device which when combined with either a plasma treatment or the coating of a diamond-like carbon (DLC) film presents a range of surface modification profiles. Experimental results presented in detail the surface modifications in the form of distinct changes in the static water contact angle across a range from 44.3 to 81.2 when compared to pristine PMMA surfaces. Additionally, capillary flow of water (dyed to aid visualization) through the microfluidic devices was recorded and analyzed to provide comparison data between filling time of a microfluidic chamber and surface modification characteristics, including the effects of surface energy and surface roughness on the microfluidic flow. We have experimentally demonstrated that fluid flow and thus filling time for the microfluidic device was significantly faster for the device with surface modifications that resulted in a lower static contact angle, and also that the incorporation of micro-pillars into a fluidic device increases the filling time when compared to comparative devices. Springer 2011-06-03 /pmc/articles/PMC3211507/ /pubmed/21711936 http://dx.doi.org/10.1186/1556-276X-6-411 Text en Copyright ©2011 Mukhopadhyay et al; licensee Springer. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Nano Idea
Mukhopadhyay, Subhadeep
Roy, Susanta S
D'Sa, Raechelle A
Mathur, Ashish
Holmes, Richard J
McLaughlin, James A
Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices
title Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices
title_full Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices
title_fullStr Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices
title_full_unstemmed Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices
title_short Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices
title_sort nanoscale surface modifications to control capillary flow characteristics in pmma microfluidic devices
topic Nano Idea
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3211507/
https://www.ncbi.nlm.nih.gov/pubmed/21711936
http://dx.doi.org/10.1186/1556-276X-6-411
work_keys_str_mv AT mukhopadhyaysubhadeep nanoscalesurfacemodificationstocontrolcapillaryflowcharacteristicsinpmmamicrofluidicdevices
AT roysusantas nanoscalesurfacemodificationstocontrolcapillaryflowcharacteristicsinpmmamicrofluidicdevices
AT dsaraechellea nanoscalesurfacemodificationstocontrolcapillaryflowcharacteristicsinpmmamicrofluidicdevices
AT mathurashish nanoscalesurfacemodificationstocontrolcapillaryflowcharacteristicsinpmmamicrofluidicdevices
AT holmesrichardj nanoscalesurfacemodificationstocontrolcapillaryflowcharacteristicsinpmmamicrofluidicdevices
AT mclaughlinjamesa nanoscalesurfacemodificationstocontrolcapillaryflowcharacteristicsinpmmamicrofluidicdevices