Cargando…
Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin
INTRODUCTION: Supraglottic airway devices have frequently been shown to facilitate airway management and are implemented in the ILCOR resuscitation algorithm. Limited data exists concerning laypersons without any medical or paramedical background. We hypothesized that even laymen would be able to op...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3213203/ https://www.ncbi.nlm.nih.gov/pubmed/22024311 http://dx.doi.org/10.1186/1757-7241-19-60 |
_version_ | 1782216102037684224 |
---|---|
author | Schälte, Gereon Stoppe, Christian Aktas, Meral Coburn, Mark Rex, Steffen Schwarz, Marlon Rossaint, Rolf Zoremba, Norbert |
author_facet | Schälte, Gereon Stoppe, Christian Aktas, Meral Coburn, Mark Rex, Steffen Schwarz, Marlon Rossaint, Rolf Zoremba, Norbert |
author_sort | Schälte, Gereon |
collection | PubMed |
description | INTRODUCTION: Supraglottic airway devices have frequently been shown to facilitate airway management and are implemented in the ILCOR resuscitation algorithm. Limited data exists concerning laypersons without any medical or paramedical background. We hypothesized that even laymen would be able to operate supraglottic airway devices after a brief training session. METHODS: Four different supraglottic airway devices: Laryngeal Mask Classic (LMA), Laryngeal Tube (LT), Intubating Laryngeal Mask (FT) and CobraPLA (Cobra) were tested in 141 volunteers recruited in a technical university cafeteria and in a shopping mall. All volunteers received a brief standardized training session. Primary endpoint was the time required to definitive insertion. In a short questionnaire applicants were asked to assess the devices and to answer some general questions about BLS. RESULTS: The longest time to insertion was observed for Cobra (31.9 ± 27.9 s, range: 9-120, p < 0.0001; all means ± standard deviation). There was no significant difference between the insertion times of the other three devices. Fewest insertion attempts were needed for the FT (1.07 ± 0.26), followed by the LMA (1.23 ± 0.52, p > 0.05), the LT (1.36 ± 0.61, p < 0.05) and the Cobra (1.45 ± 0.7, p < 0.0001). Ventilation was achieved on the first attempt significantly more often with the FT (p < 0.001) compared to the other devices. Nearly 90% of the participants were in favor of implementing supraglottic airway devices in first aid algorithms and classes. CONCLUSION: Laypersons are able to operate supraglottic airway devices in manikin with minimal instruction. Ventilation was achieved with all devices tested after a reasonable time and with a high success rate of > 95%. The use of supraglottic airway devices in first aid and BLS algorithms should be considered. |
format | Online Article Text |
id | pubmed-3213203 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-32132032011-11-11 Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin Schälte, Gereon Stoppe, Christian Aktas, Meral Coburn, Mark Rex, Steffen Schwarz, Marlon Rossaint, Rolf Zoremba, Norbert Scand J Trauma Resusc Emerg Med Original Research INTRODUCTION: Supraglottic airway devices have frequently been shown to facilitate airway management and are implemented in the ILCOR resuscitation algorithm. Limited data exists concerning laypersons without any medical or paramedical background. We hypothesized that even laymen would be able to operate supraglottic airway devices after a brief training session. METHODS: Four different supraglottic airway devices: Laryngeal Mask Classic (LMA), Laryngeal Tube (LT), Intubating Laryngeal Mask (FT) and CobraPLA (Cobra) were tested in 141 volunteers recruited in a technical university cafeteria and in a shopping mall. All volunteers received a brief standardized training session. Primary endpoint was the time required to definitive insertion. In a short questionnaire applicants were asked to assess the devices and to answer some general questions about BLS. RESULTS: The longest time to insertion was observed for Cobra (31.9 ± 27.9 s, range: 9-120, p < 0.0001; all means ± standard deviation). There was no significant difference between the insertion times of the other three devices. Fewest insertion attempts were needed for the FT (1.07 ± 0.26), followed by the LMA (1.23 ± 0.52, p > 0.05), the LT (1.36 ± 0.61, p < 0.05) and the Cobra (1.45 ± 0.7, p < 0.0001). Ventilation was achieved on the first attempt significantly more often with the FT (p < 0.001) compared to the other devices. Nearly 90% of the participants were in favor of implementing supraglottic airway devices in first aid algorithms and classes. CONCLUSION: Laypersons are able to operate supraglottic airway devices in manikin with minimal instruction. Ventilation was achieved with all devices tested after a reasonable time and with a high success rate of > 95%. The use of supraglottic airway devices in first aid and BLS algorithms should be considered. BioMed Central 2011-10-24 /pmc/articles/PMC3213203/ /pubmed/22024311 http://dx.doi.org/10.1186/1757-7241-19-60 Text en Copyright ©2011 Schälte et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Research Schälte, Gereon Stoppe, Christian Aktas, Meral Coburn, Mark Rex, Steffen Schwarz, Marlon Rossaint, Rolf Zoremba, Norbert Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin |
title | Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin |
title_full | Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin |
title_fullStr | Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin |
title_full_unstemmed | Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin |
title_short | Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin |
title_sort | laypersons can successfully place supraglottic airways with 3 minutes of training. a comparison of four different devices in the manikin |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3213203/ https://www.ncbi.nlm.nih.gov/pubmed/22024311 http://dx.doi.org/10.1186/1757-7241-19-60 |
work_keys_str_mv | AT schaltegereon laypersonscansuccessfullyplacesupraglotticairwayswith3minutesoftrainingacomparisonoffourdifferentdevicesinthemanikin AT stoppechristian laypersonscansuccessfullyplacesupraglotticairwayswith3minutesoftrainingacomparisonoffourdifferentdevicesinthemanikin AT aktasmeral laypersonscansuccessfullyplacesupraglotticairwayswith3minutesoftrainingacomparisonoffourdifferentdevicesinthemanikin AT coburnmark laypersonscansuccessfullyplacesupraglotticairwayswith3minutesoftrainingacomparisonoffourdifferentdevicesinthemanikin AT rexsteffen laypersonscansuccessfullyplacesupraglotticairwayswith3minutesoftrainingacomparisonoffourdifferentdevicesinthemanikin AT schwarzmarlon laypersonscansuccessfullyplacesupraglotticairwayswith3minutesoftrainingacomparisonoffourdifferentdevicesinthemanikin AT rossaintrolf laypersonscansuccessfullyplacesupraglotticairwayswith3minutesoftrainingacomparisonoffourdifferentdevicesinthemanikin AT zorembanorbert laypersonscansuccessfullyplacesupraglotticairwayswith3minutesoftrainingacomparisonoffourdifferentdevicesinthemanikin |