Cargando…

A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants

PURPOSE: The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the pla...

Descripción completa

Detalles Bibliográficos
Autores principales: Yun, Hee-Jung, Park, Jung-Chul, Yun, Jeong-Ho, Jung, Ui-Won, Kim, Chang-Sung, Choi, Seong-Ho, Cho, Kyoo-Sung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Periodontology 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3213231/
https://www.ncbi.nlm.nih.gov/pubmed/22087411
http://dx.doi.org/10.5051/jpis.2011.41.5.211
_version_ 1782216107161026560
author Yun, Hee-Jung
Park, Jung-Chul
Yun, Jeong-Ho
Jung, Ui-Won
Kim, Chang-Sung
Choi, Seong-Ho
Cho, Kyoo-Sung
author_facet Yun, Hee-Jung
Park, Jung-Chul
Yun, Jeong-Ho
Jung, Ui-Won
Kim, Chang-Sung
Choi, Seong-Ho
Cho, Kyoo-Sung
author_sort Yun, Hee-Jung
collection PubMed
description PURPOSE: The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well as the level of bone around the implants. METHODS: The subjects of this study were 27 patients (79 implants) undergoing treatment with microthreaded and platform-switched implants between October 2008 and July 2009 in the Dental Hospital of Yonsei University Department of Periodontology. The patients received follow-up care more than 6 months after the final setting of the prosthesis, at which time periapical radiographs were taken. The marginal bone level was measured from the reference point to the lowest observed point of contact between the marginal bone and the fixture. Comparisons were made between radiographs taken at the time of fixture installation and those taken at the follow-up visit. RESULTS: During the study period (average of 11.8 months after fixture installation and 7.4 months after the prosthesis delivery), the short-term survival rate of microthreaded and platform-switched implants was 100% and the marginal bone loss around implants was 0.16±0.08 mm, the latter of which is lower than the previously reported values. CONCLUSIONS: This short-term clinical study has demonstrated the successful survival rates of a microthread and platform-switched implant system, and that this system is associated with reduced marginal bone loss.
format Online
Article
Text
id pubmed-3213231
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Korean Academy of Periodontology
record_format MEDLINE/PubMed
spelling pubmed-32132312011-11-15 A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants Yun, Hee-Jung Park, Jung-Chul Yun, Jeong-Ho Jung, Ui-Won Kim, Chang-Sung Choi, Seong-Ho Cho, Kyoo-Sung J Periodontal Implant Sci Research Article PURPOSE: The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well as the level of bone around the implants. METHODS: The subjects of this study were 27 patients (79 implants) undergoing treatment with microthreaded and platform-switched implants between October 2008 and July 2009 in the Dental Hospital of Yonsei University Department of Periodontology. The patients received follow-up care more than 6 months after the final setting of the prosthesis, at which time periapical radiographs were taken. The marginal bone level was measured from the reference point to the lowest observed point of contact between the marginal bone and the fixture. Comparisons were made between radiographs taken at the time of fixture installation and those taken at the follow-up visit. RESULTS: During the study period (average of 11.8 months after fixture installation and 7.4 months after the prosthesis delivery), the short-term survival rate of microthreaded and platform-switched implants was 100% and the marginal bone loss around implants was 0.16±0.08 mm, the latter of which is lower than the previously reported values. CONCLUSIONS: This short-term clinical study has demonstrated the successful survival rates of a microthread and platform-switched implant system, and that this system is associated with reduced marginal bone loss. Korean Academy of Periodontology 2011-10 2011-10-31 /pmc/articles/PMC3213231/ /pubmed/22087411 http://dx.doi.org/10.5051/jpis.2011.41.5.211 Text en Copyright © 2011 Korean Academy of Periodontology This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/).
spellingShingle Research Article
Yun, Hee-Jung
Park, Jung-Chul
Yun, Jeong-Ho
Jung, Ui-Won
Kim, Chang-Sung
Choi, Seong-Ho
Cho, Kyoo-Sung
A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants
title A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants
title_full A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants
title_fullStr A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants
title_full_unstemmed A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants
title_short A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants
title_sort short-term clinical study of marginal bone level change around microthreaded and platform-switched implants
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3213231/
https://www.ncbi.nlm.nih.gov/pubmed/22087411
http://dx.doi.org/10.5051/jpis.2011.41.5.211
work_keys_str_mv AT yunheejung ashorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT parkjungchul ashorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT yunjeongho ashorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT junguiwon ashorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT kimchangsung ashorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT choiseongho ashorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT chokyoosung ashorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT yunheejung shorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT parkjungchul shorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT yunjeongho shorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT junguiwon shorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT kimchangsung shorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT choiseongho shorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants
AT chokyoosung shorttermclinicalstudyofmarginalbonelevelchangearoundmicrothreadedandplatformswitchedimplants